ABSTRACT This specification details the minimum property, design and construction requirements for flexible removable and reusable blanket insulation for hot service of above ambient temperatures. Insulation must be one of the following flexible fibrous materials acceptable for the maximum temperature of service: high temperature fiber blanket of any type or grade; needled glass fiber mechanically bonded felt; and mineral fiber blanket of the type suitable for the application. The material for the outer jacket liner and straps, where used, shall either be plain woven glass fiber fabric or that which has been treated with a water resistant compound such as silicone or fluorocarbon, and conforms with the following requirements: minimum weight; breaking strength; tear strength; burst strength; abrasion resistance; color; temperature resistance; and flame resistance. SCOPE 1.1 This specification addresses the minimum requirements for materials and fabrication of flexible removable and reusable blanket insulation for hot service, from above ambient temperatures to 1000°F (538°C). 1.2 This specification separately addresses industrial applications, outdoor commercial applications, and indoor commercial applications. Blanket insulation for industrial applications and outdoor commercial applications must be weather resistant and resistant to liquid chemicals. Blanket insulation for indoor commercial applications is limited to 500°F (260°C) maximum use temperature, is not required to be either weather resistant or resistant to chemicals, and is typically used for HVAC, plumbing, and other light grade indoor piping systems that distribute steam or water, or both. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM C1695-22: Standard Specification for Fabrication of Flexible Removable and Reusable Blanket Insulation for Hot Service is a critical international standard developed by ASTM for the thermal insulation industry. This specification sets the minimum requirements for the materials, design, and construction of flexible, removable, and reusable insulation blankets used in hot service applications above ambient temperatures, up to 1000°F (538°C). The standard covers a range of fibrous insulation materials including high-temperature fiber blankets, needled glass fiber felts, mineral fiber blankets, microporous thermal insulation, and flexible aerogel insulation, all tailored for specific operational requirements.
Key Topics
- Material Requirements: The standard outlines acceptable insulation materials, including high-temperature fiber blankets (per ASTM C892), needled glass fiber felt (ASTM C1086), mineral fiber blankets (ASTM C553), microporous insulation (ASTM C1676), and aerogel insulation (ASTM C1728). For outer jackets, liners, and straps, woven glass fiber fabric treated with water-resistant compounds such as silicone or PTFE is specified.
- Performance Criteria: Materials must meet specified minimums for weight, breaking strength, tear strength, burst strength, abrasion resistance, temperature resistance, and flame resistance.
- Fabrication and Design: Requirements include pre-measurement for a tight fit, construction details for seams, parting faces for drainage, overlap with adjacent insulation, and geometric design to avoid force-folding. There are also detailed stipulations for tie-down straps, drawstrings, and identification tags.
- Application-Specific Criteria: The standard distinguishes between industrial, outdoor commercial, and indoor commercial applications:
- Industrial and outdoor applications require weather and chemical resistance.
- Indoor commercial insulation (e.g., HVAC or plumbing) is rated for temperatures up to 500°F (260°C) and is typically not required to provide weather or chemical resistance.
- Quality Assurance: Detailed inspection, rejection, and tagging protocols ensure correct identification and tracking of insulation products.
Applications
ASTM C1695-22 is essential for industries where energy conservation, safety, and maintenance flexibility are critical. Examples include:
- Industrial Facilities: Insulation for valves, flanges, piping, and equipment operating at high temperatures, often exposed to outdoor conditions, chemicals, or physical abuse.
- Power Plants and Refineries: Removable and reusable blankets allow for easy access for inspection and maintenance while providing thermal efficiency and personnel protection.
- HVAC and Commercial Plumbing Systems: Indoor removable insulation for steam, hot water, and process piping ensures easy maintenance while maintaining energy efficiency.
- OEM Equipment: Manufacturers can design equipment with tailored, removable insulation solutions that meet demanding operational or environmental requirements.
Removable and reusable insulation blankets built to ASTM C1695-22 offer significant benefits, such as:
- Simplified maintenance and inspection with minimal downtime
- Enhanced worker safety through controlled surface temperatures
- Improved process efficiency via consistent thermal insulation
- Reduced waste and cost over the lifecycle of insulated assets
Related Standards
ASTM C1695-22 is closely linked to several other ASTM standards for insulation materials and testing, including:
- ASTM C168: Terminology Relating to Thermal Insulation
- ASTM C553: Specification for Mineral Fiber Blanket Thermal Insulation
- ASTM C892: Specification for High-Temperature Fiber Blanket Thermal Insulation
- ASTM C1086: Specification for Glass Fiber Mechanically Bonded Felt Thermal Insulation
- ASTM C1676: Specification for Microporous Thermal Insulation
- ASTM C1728: Specification for Flexible Aerogel Insulation
- ASTM C1129: Practice for Estimation of Heat Savings by Adding Thermal Insulation
- ASTM D3389/D3776/D3786/D5034/D5035/D5587/D6413: Various tests for textile performance (abrasion, weight, burst strength, breaking and tear strength, and flame resistance)
- MIL-C-20079H: Military Specification for Glass Cloth and Yarn
Enterprises implementing ASTM C1695-22 can ensure compliance, enhance facility reliability, and maximize energy management in high-temperature environments.
Технические детали
- Технический комитет
- C16 - Thermal Insulation
- SKU
- ASTM C1695-22
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…