ASTM C1710-24 PDF
Standard Guide for Installation of Flexible Closed Cell Preformed Insulation in Tube and Sheet Form
Standard Guide for Installation of Flexible Closed Cell Preformed Insulation in Tube and Sheet Form
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 1 марта 2024 г.
- Издание:
- C1710
- ICS:
- 29.035.20
SIGNIFICANCE AND USE 5.1 This guide applies to flexible closed cell insulation tubing and sheet materials manufactured according to Specifications C534 and C1427. This standard is intended to provide a basic guide for installing these types of materials. 5.2 Confirm application use temperature is consistent with specified use temperature for material as defined in ASTM Specifications unless otherwise agreed upon with the manufacturer. There are different grades for each of the insulation types referred to in this guide, material and grade installed should be that specified. 5.3 This guide is not intended to cover all aspects associated with installation for all applications, consult the National, Commercial Industrial Insulation Standards (MICA Manual) or the specific product manufacturer for recommendations, or both. See ASHRAE Handbook (Fundamentals – Chapter 23) and ASHRAE Handbook (Refrigeration – Chapter 10). SCOPE 1.1 This guide covers recommended installation techniques for flexible closed cell pre-formed insulation in tube or sheet form. This guide is applicable to materials manufactured in accordance with Specification C534 (Elastomeric based insulation) or Specification C1427 (polyolefin based insulation). The materials covered in this guide encompass a service temperature of –297 to 300°F (–183 to 150°C) as indicated in the material specifications referenced above. Many of the recommendations made are specific to below ambient applications only. 1.2 The purpose of this guide is to optimize the thermal performance and longevity of installed closed cell flexible insulation systems. By following this guide, the owner, and designer can expect to achieve the energy savings expected and prevention of condensation under the specified design conditions. This document is limited to installation procedures and does not encompass system design. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM C1710-24: Standard Guide for Installation of Flexible Closed Cell Preformed Insulation in Tube and Sheet Form provides comprehensive guidelines for the proper installation of flexible closed cell tubular and sheet insulation materials. These materials are widely used for thermal insulation in HVAC systems, piping, vessels, and ducts. The guide applies to products manufactured in accordance with ASTM C534 (elastomeric-based insulation) and ASTM C1427 (polyolefin-based insulation), with a focus on preserving thermal performance, energy efficiency, and moisture control.
Designed for professionals in mechanical insulation, this standard supports energy savings, condensation prevention, and system longevity through the use of best installation practices.
Key Topics
-
Material Scope and Temperature Range
- Coverage includes elastomeric and polyolefin flexible closed cell insulation in tube and sheet form.
- Applicable to systems functioning within –297°F to 300°F (–183°C to 150°C), as specified by manufacturer standards.
-
Installation Best Practices
- Do not pull or stretch insulation; always push or slightly oversize to maintain thickness.
- Surfaces must be clean and dry before application. Special care is needed for systems in operation to prevent moisture entrapment.
- All seams, butt joints, cutouts, and termination points must be sealed with an approved adhesive system to prevent air and moisture ingress.
- For below-ambient applications and high humidity environments, use vapor stops and barriers to control moisture migration.
-
Special Situations
- Guidance for fitting insulation, including elbows, tees, valves, and large diameter pipes.
- Recommendations for pipes, ducts, tanks, vessels, and when layering insulation.
- Mechanical protection-such as jacketing or cladding-is recommended for areas subject to mechanical abuse or outdoor installation.
-
Inspection and Safety
- Final inspection should ensure correct material, size, and absence of damage or unsealed seams, which are the most common cause of insulation failure.
- Users must establish appropriate health, safety, and environmental procedures, including ventilation and personal protective equipment when using adhesives.
Applications
Flexible closed cell preformed insulation is essential for:
- Mechanical Piping Systems: Used extensively on chilled water, refrigeration lines, and hot water piping to prevent condensation, maintain energy efficiency, and provide long-term thermal protection.
- HVAC Ductwork: Wrapped on rectangular, round, or oval ducts for temperature control and condensation prevention, especially in commercial and industrial settings.
- Process Equipment: Insulating tanks, vessels, and large diameter process pipes in commercial and industrial facilities.
- Special Environments: Suitable for applications requiring resistance to below-ambient temperatures, direct burial (with appropriate recommendations), or systems exposed to outdoor conditions.
By adhering to this guide, facility owners, engineers, and insulation contractors can expect optimal system performance, reduced energy loss, and longer service life for insulated systems.
Related Standards
- ASTM C534: Specification for Preformed Flexible Elastomeric Cellular Thermal Insulation in Sheet and Tubular Form
- ASTM C1427: Specification for Extruded Preformed Flexible Cellular Polyolefin Thermal Insulation in Sheet and Tubular Form
- ASTM C585: Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing
- MICA Manual: National Commercial and Industrial Insulation Standards
- ASHRAE Handbook: Fundamentals (Chapter 23) and Refrigeration (Chapter 10)
These documents collectively provide a framework for selecting, installing, and maintaining flexible closed cell insulation systems in a wide variety of commercial, industrial, and institutional applications.
ASTM C1710-24 ensures that flexible closed cell insulation systems are properly installed for maximum performance, addressing energy efficiency, condensation control, and installation quality across various mechanical and building services applications.
Технические детали
- Технический комитет
- C16 - Thermal Insulation
- SKU
- ASTM C1710-24
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…