ASTM C507M-22 PDF
Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)
Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 11
- Дата публикации:
- 1 сентября 2022 г.
- Издание:
- C507M
- ICS:
- 23.040.50
ABSTRACT This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. Pipe design based on its major axis shall be designated as horizontal and vertical elliptical pipe. The reinforced concrete shall consist of cementitious materials, mineral aggregates, and water, in which steel has been embedded in such a manner that the steel and concrete act together. The combination of cementitious materials used in the concrete shall only be one of the following: Portland cement, Portland blast furnace slag cement, slag modified Portland cement, Portland pozzolan cement, a combination of Portland cement and ground granulated blast-furnace slag, a combination of Portland cement and fly ash, a combination of Portland cement, ground granulated blast-furnace slag, and fly ash. Collated fibrillated virgin polypropylene fibers may be used. Design of pipe such as size, shape, special designs, and area, shall be as listed in the specification. Circumferential, longitudinal, and joint reinforcements shall meet the requirements of this specification. Mixture and curing of pipe shall conform to the requirements of this specification. Compression tests determining concrete compressive strength may be made on either standard rodded concrete cylinders or concrete cylinders compacted and cured in like manner as the pipe, or on cores drilled from the pipe. Pipe may be repaired because of imperfections in manufacture or damage during handling and shall be acceptable if the repaired pipe conforms to the requirements of this specification. SCOPE 1.1 This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 Pipe designed for placement with the major axis horizontal shall be designated as “Horizontal Elliptical Pipe.” Pipe designed for placement with the major axis vertical shall be designated as “Vertical Elliptical Pipe.” 1.3 This specification is the SI companion to Specification C507; therefore, no inch-pound equivalents are presented in this specification. Reinforced concrete pipe that conforms to the requirements of C507 are acceptable under this Specification C507M unless prohibited by the owner. Note 1: This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM C507M-22 is a standard specification developed by ASTM International for reinforced concrete elliptical culvert, storm drain, and sewer pipe (metric). This international standard covers reinforced, elliptically shaped concrete pipe used for the conveyance of sewage, industrial wastes, stormwater, and for constructing culverts in civil and municipal infrastructure. The document sets forth the criteria for the design, manufacturing, materials, testing, and acceptance of such pipe in metric units, ensuring product reliability, durability, and safety in wastewater and stormwater management systems.
Key Topics
-
Product Scope The standard specifically applies to horizontally and vertically placed elliptical concrete pipes, classifying them as Horizontal Elliptical Pipe and Vertical Elliptical Pipe respectively.
-
Materials Reinforced concrete pipes under this specification are made from cementitious materials (such as Portland cement, blended cements, slag, and fly ash), mineral aggregates, and water, with embedded steel reinforcement for structural integrity. Admixtures, including air-entraining and chemical admixtures, as well as synthetic and nonsynthetic fibers, are also permitted.
-
Reinforcement Requirements The reinforcement, either as wire, welded wire, or steel bars, must conform to specific ASTM standards. The standard clearly outlines the required area, placement, and configuration of circumferential, longitudinal, and joint reinforcement.
-
Design and Acceptance ASTM C507M-22 provides minimum design dimensions, reinforcement areas, and compressive strength values for each class of pipe. The acceptance of the pipe can be based on load-bearing tests, material tests, and inspections for visual defects.
-
Manufacturing and Curing The mixing, proportioning, and curing processes must meet prescribed requirements to achieve the specified concrete strength. Approved curing methods include steam curing, water curing, and membrane curing.
-
Testing and Inspection Pipes are tested for external load crushing strength, compressive strength, and absorption, following established ASTM test methods. Procedures for retesting and acceptance criteria are included to ensure quality control.
-
Dimensional Tolerances The standard controls permissible variations in internal dimensions and wall thickness, ensuring consistent product performance.
Applications
ASTM C507M-22 provides essential requirements for the design, procurement, and quality assurance of reinforced concrete elliptical pipes used in:
- Sewage Systems Transporting municipal and industrial wastewater reliably and safely.
- Storm Drainage Managing stormwater flow in urban and roadway drainage systems.
- Culverts Constructing under-road or embankment crossings where site conditions favor elliptical shapes for clearance or hydraulic requirements.
These products are vital in municipal infrastructure, public works, industrial facilities, and transportation projects. The specification is a critical tool for engineers, specifiers, contractors, and manufacturers in ensuring compliance, structural performance, and regulatory acceptance for reinforced concrete pipes.
Related Standards
For comprehensive project specifications and product interoperability, ASTM C507M-22 references and aligns with several related standards, including:
- ASTM C507 - U.S. inch-pound companion standard for reinforced concrete elliptical pipe.
- ASTM C33/C33M - Concrete aggregates specification.
- ASTM C150/C150M, C595/C595M, C989/C989M, C618 - Covering allowable cementitious materials.
- ASTM A36/A36M, A615/A615M, A706/A706M, A1064/A1064M - Steel reinforcement requirements.
- ASTM C260/C260M, C494/C494M, C1116/C1116M - Permitted admixtures and fiber reinforcement.
- ASTM C443M, C990M - Jointing systems and rubber gaskets.
- ASTM C497M - Test methods for concrete pipe performance.
Referencing these standards supports streamlined procurement, construction quality, and international interoperability for reinforced concrete pipe installations.
Optimize your stormwater, sewage, and culvert projects with confidence by specifying ASTM C507M-22 compliant reinforced concrete elliptical pipe, ensuring performance, quality, and adherence to internationally recognized standards.
Технические детали
- Технический комитет
- C13 - Concrete Pipe
- SKU
- ASTM C507M-22
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…