SIGNIFICANCE AND USE 4.1 The purpose of this practice is to ensure satisfactory fit on standard sizes, to accommodate radial expansion of pipes and tubes which are heated after being insulated, and to minimize the number of insulation sizes and thicknesses to be manufactured and stocked. 4.2 While it is possible to manufacturer insulation to these recommended dimensions, exercise care in attempting to nest layers of different materials, or layers supplied by different manufacturers. Individual manufacturing processes will operate at slightly different tolerances. While the product will fit the pipe, it is possible that it will not readily nest as the outer layer between the different materials, or with a different manufacturer, and possibly the same manufacturer. Exercise care to determine these differences before specifying or ordering nesting sizes. 4.3 The wide range of outer diameter dimensional tolerances will prevent many pipe and tube insulations from nesting for staggered joints or double layered applications, or both unless specified when ordered from the manufacturer, distributor, or fabricator. 4.4 Dimensions in accordance with this practice do not necessarily permit application of one thickness of pipe insulation over another (Nesting or Simplified Dimensional System) to obtain total thicknesses greater than those manufactured as single layer, or for multilayer application when desired. FIG. 3 Hinged Section Measurement Location SCOPE 1.1 This practice is intended as a dimensional standard for preformed thermal insulation for pipes and tubing. 1.2 This practice covers insulation supplied in cylindrical sections and lists recommended single layer inner and outer diameters of insulation having nominal wall thicknesses from 1/2 to 5 in. (13 to 127 mm) to fit over standard sizes of pipe and tubing. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values stated in SI units are provided for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM C585-22 is an internationally recognized standard practice developed by ASTM International for the specification of inner and outer diameters of preformed thermal insulation used on nominal pipe and tubing sizes. This standard provides a dimensional framework for insulation manufacturers, distributors, and specifiers to ensure satisfactory fit over standard pipe and tubing, accommodate thermal expansion, and support efficient inventory management by reducing the number of insulation sizes and thicknesses that need to be manufactured or stocked.
Suitable for use with a variety of insulation materials including calcium silicate, cellular foam plastics, cellular glass, mineral fiber, perlite, flexible elastomeric, and polyolefin, ASTM C585-22 ensures industry-wide consistency and compatibility in thermal insulation for piping systems across commercial, industrial, and institutional facilities.
Key Topics
- Dimensional Guidance: Specifies recommended single-layer inner and outer diameters for pipe and tubing insulation ranging from 1/2 to 5 inches (13 to 127 mm) nominal wall thickness.
- Fit and Expansion: Designed to ensure a proper fit on standard pipe and tubing sizes and to accommodate the radial expansion that occurs when pipes are heated.
- Tolerance and Measurement: Details methods and tolerances for measuring inner and outer diameters, including requirements for half and hinged insulation sections.
- Nesting Considerations: Addresses potential challenges with nesting or layering insulation from different materials or manufacturers, emphasizing the need for careful specification if multi-layer applications are involved.
- Units of Measurement: Values are provided in inch-pound units as the standard, with SI units included for reference.
- Material Applicability: Applies to numerous insulation types commonly used in mechanical and process piping applications.
Applications
ASTM C585-22 is essential in industries and applications where precise thermal insulation aids in energy conservation, temperature control, and equipment protection:
- HVAC and Plumbing Systems: Ensures accurate selection and installation of pipe insulation for hot and cold water, steam, and chilled water systems.
- Industrial Facilities: Supports insulation for process piping in power plants, chemical plants, refineries, and food processing plants.
- Commercial Buildings: Used in mechanical rooms and piping runs to maintain energy efficiency and protect building systems.
- Multilayer Insulation Systems: While not inherently intended for nesting or multilayer builds, the standard highlights the need for explicit specification if such applications are required.
- Project Specifications: Provides a uniform reference point for engineers, contractors, and facility managers when specifying insulation products for bids and submittals.
Related Standards
The guidance provided by ASTM C585-22 complements a range of other ASTM and industry standards related to thermal insulation:
- ASTM C168 - Terminology Relating to Thermal Insulation
- ASTM C302 - Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation
- ASHRAE Standards - Pertaining to insulation performance in HVAC applications
- ASTM C335 / C518 - Related to thermal conductivity testing of insulation materials
By adhering to ASTM C585-22, stakeholders in construction, manufacturing, and facility management can ensure dimensional compatibility, optimize thermal insulation performance, and maintain regulatory and industry best practices for piping insulation systems.
Keywords: pipe thermal insulation diameter, pipe insulation standards, tubing insulation dimensions, insulation dimensional tolerance, thermal insulating materials, ASTM C585-22, pipe insulation fit, HVAC insulation standards, mechanical piping insulation specifications.
Технические детали
- Технический комитет
- C16 - Thermal Insulation
- SKU
- ASTM C585-22
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…