ASTM D5126/D5126M-16 PDF
Standard Guide for Comparison of Field Methods for Determining Hydraulic Conductivity in Vadose Zone
Standard Guide for Comparison of Field Methods for Determining Hydraulic Conductivity in Vadose Zone
- Статус документа:
- D
- Формат:
- Электронный (PDF)
- Количество страниц:
- 12
- Дата публикации:
- 1 июля 2016 г.
- Издание:
- D5126/D5126M
- ICS:
- 07.060
SIGNIFICANCE AND USE 5.1 Saturated hydraulic conductivity measurements are made for a variety of purposes varying from design of landfills and construction of clay liners to assessment of irrigation systems. Infiltrometers are commonly used where infiltration or percolation rates through a surface or subsurface layer are desired. Evaluation of the rate of water movement through a pond liner is one example of this kind of measurement. Penetration of the liner by a borehole would invalidate the measurement of liner permeability. It has been noted that small-ring infiltrometers are subject to error due to lateral divergence of flow. Therefore, techniques using very large (1 to 2-m diameter) infiltration basins have been recommended for measuring the very slow percolation rates typically needed for clay liners. The air-entry permeameter can be used instead of infiltrometer tests to avoid lateral divergence of flow. However, because a cylinder must be driven into the media tested, the actual soil column tested may be disrupted by introduction of the cylinder, especially in structured soils. 5.2 Borehole tests for determining saturated hydraulic conductivity are applicable for evaluating the rate of water movement through subsurface layers. For slowly permeable layers, an accurate method of measuring the rate of water movement into the borehole will need to be developed. Use of a flexible bag as a reservoir that can be periodically weighed is advisable for these conditions. A number of mathematical solutions for borehole outflow data are available (Stephens et al. (17), Reynolds et al. (18), and Philip (19)). 5.3 Information on unsaturated flow rates is needed to design hazardous waste landfills and impoundments where prevention of flow of contaminants into groundwater is needed. Of the test methods available, the primary differences are cost and resultant bias and precision. The instantaneous profile test method appears to provide very reliable data because it uses a large volume of so... SCOPE 1.1 This guide covers a review of the test methods for determining hydraulic conductivity in unsaturated soils and sediments. Test methods for determining both field-saturated and unsaturated hydraulic conductivity are described. 1.2 Measurement of hydraulic conductivity in the field is used for estimating the rate of water movement through clay liners to determine if they are a barrier to water flux, for characterizing water movement below waste disposal sites to predict contaminant movement, and to measure infiltration and drainage in soils and sediment for a variety of applications. Test methods are needed for measuring hydraulic conductivity ranging from 1 × 10−2 to 1 × 10−8 cm/s, for both surface and subsurface layers, and for both field-saturated and unsaturated flow. 1.3 For these field test methods a distinction is made between “saturated” (Ks) and “field-saturated” (Kfs) hydraulic conductivity. True saturated conditions seldom occur in the vadose zone except where impermeable layers result in the presence of perched water tables. During infiltration events or in the event of a leak from a lined pond, a “field-saturated” condition develops. True saturation does not occur due to entrapped air (1).2 The entrapped air prevents water from moving in air-filled pores that, in turn, may reduce the hydraulic conductivity measured in the field by as much as a factor of two compared to conditions when trapped air is not present (2). Field test methods should simulate the “field-saturated” condition. 1.4 Field test methods commonly used to determine field-saturated hydraulic conductivity include various double-ring infiltrometer test methods, air-entry permeameter test methods, and borehole permeameter tests. Many empirical test methods are used for calculating hydraulic conductivity from data obtained with each test method. A general description of each test method and special characteristics affecting applicabili...
Технические детали
- Технический комитет
- D18 - Soil and Rock
- SKU
- ASTM D5126/D5126M-16
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…