ASTM D5337-23 PDF
Standard Practice for Setting and Verifying the Flow Rate of Personal Sampling Pumps
Standard Practice for Setting and Verifying the Flow Rate of Personal Sampling Pumps
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 5
- Дата публикации:
- 1 мая 2023 г.
- Издание:
- D5337
- ICS:
- 23.080
SIGNIFICANCE AND USE 5.1 Most occupational exposure assessment methods require the use of personal sampling pumps to collect air samples at typical sampling flow rates, with sampling volumes specified by (a) particular procedure(s). The precision and bias of these methods are directly affected by the precision and bias of the pumps used in the measurement of the air volume(s) sampled. SCOPE 1.1 This practice describes the setting and verification of flow rate for sampling pumps commonly used for monitoring personal airborne exposures in the workplace. 1.2 This practice includes procedures for using working standard flow meters that are traceable to national or international standards, as well as those that are not. Traceable standards are preferred. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM D5337-23: Standard Practice for Setting and Verifying the Flow Rate of Personal Sampling Pumps specifies procedures for calibrating, setting, and verifying the flow rate of personal air sampling pumps in workplace environments. These pumps are essential tools in occupational exposure assessment, ensuring accurate collection of airborne contaminants for workplace air quality evaluation. The standard outlines best practices to maintain the precision and reliability of sampling equipment through traceable calibration methods and documentation.
By adhering to ASTM D5337-23, organizations can ensure that their air sampling results are accurate and reliable, supporting compliance with occupational health regulations and improving the protection of worker health.
Key Topics
- Flow Rate Calibration: Detailed steps for calibrating and verifying the flow rate of personal sampling pumps before and after workplace air sampling.
- Working Standard Flow Meters: Instructions for using both traceable and non-traceable working standard flow meters, with a preference for traceable devices.
- Traceability and Accreditation: Recommendations for ensuring calibration traceability to national or international standards, and the use of accredited laboratories.
- Measurement Devices: Guidance on implementing a variety of flow meters, such as bubble burettes, electronic near-frictionless piston meters, rotameters, and mass flow meters, for accurate volume measurements.
- Primary and Secondary Calibration: Procedures for both primary (traceable) and secondary (field) calibration devices, including establishment of calibration graphs.
- Quality Control: Requirements for pre- and post-sampling flow rate checks to identify potential deviations and ensure sampling integrity.
- Safety and Compliance: Emphasis on user responsibility in establishing proper safety, health, and environmental practices while applying the standard.
Applications
ASTM D5337-23 is crucial for a range of occupational hygiene and industrial hygiene applications:
- Workplace Air Monitoring: Ensures correct air sampling flow rates for accurate assessment of exposure to hazardous substances like dusts, fumes, vapors, and gases.
- Regulatory Compliance: Supports organizations in meeting occupational exposure limit requirements, and in preparing for regulatory inspections.
- Sampling Equipment Maintenance: Provides a consistent procedure for routine calibration, verification, and maintenance of personal sampling pumps to improve data quality.
- Health and Safety Programs: Enables professionals to establish reliable exposure monitoring programs that protect worker health and safety.
- Industrial and Laboratory Settings: Standardizes calibration procedures across different environments, from field sites to analytical laboratories, ensuring comparability of results.
Related Standards
The practice described in ASTM D5337-23 is closely linked or referenced by several international and national standards, facilitating comprehensive air monitoring strategies:
- ASTM D1356: Terminology Relating to Sampling and Analysis of Atmospheres
- ASTM D4532: Test Method for Respirable Dust in Workplace Atmospheres Using Cyclone Samplers
- ISO 13137: Workplace atmospheres - Pumps for personal sampling of chemical and biological agents - Requirements and test methods
- ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories
- NIOSH NMAM 0600: Guidance for air sampling and analytical procedures (National Institute for Occupational Safety and Health)
- OSHA Analytical Methods Manual & Technical Manual: Comprehensive references for occupational air sampling standards
Keywords: ASTM D5337, personal sampling pumps, flow rate calibration, workplace air quality, air monitoring, traceable calibration, occupational exposure assessment, flow meters, industrial hygiene, calibration verification, workplace atmospheres, health and safety compliance
Технические детали
- Технический комитет
- D22 - Air Quality
- SKU
- ASTM D5337-23
Похожие стандарты
Упомянутые в описании и другие стандарты ASTM
SIST EN ISO 13137:2023
ДействующийWorkplace atmospheres - Pumps for personal sampling of chemical and biological agents - Requirements and test…
Overview EN ISO 13137:2022 - Workplace atmospheres: Pumps for personal sampling of chemical and biological agents - specifies performance requirements and test methods for battery‑powered personal sa…
ISO 6141:2015/Amd 1:2020
ДействующийGas analysis — Contents of certificates for calibration gas mixtures — Amendment 1: Cross reference list to I…
Overview ISO 6141:2015/Amd 1:2020 is an important amendment to the international standard ISO 6141:2015, which specifies the contents of certificates for calibration gas mixtures used in gas analysis…
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol