ASTM D5635/D5635M-18(2022) PDF
Standard Test Method for Dynamic Puncture Resistance of Roofing Membrane Specimens
Standard Test Method for Dynamic Puncture Resistance of Roofing Membrane Specimens
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 5
- Дата публикации:
- 1 ноября 2022 г.
- Издание:
- D5635/D5635M
- ICS:
- 91.100.50
SIGNIFICANCE AND USE 5.1 An important factor affecting the performance of membrane roofing systems is their ability to resist dynamic puncture impacts. This test method provides a means to assess dynamic puncture resistance. 5.2 This test method can be used to compare the dynamic puncture resistance of a single type of membrane as a function of a variety of insulation substrates or, conversely, to compare the resistance of a number of membrane specimens set on a single type of insulation. 5.3 The effect of temperature on puncture resistance can be studied by conducting the test under controlled conditions using such equipment as an environmental chamber, oven, or freezer. 5.4 The test method can be useful in developing performance criteria for membrane roofing systems. 5.5 The test method can be useful in developing classifications of dynamic puncture resistance of membrane roofing systems. 5.6 While it is considered that the results obtained by this laboratory test can afford a measure of the dynamic puncture resistance of membrane roofing systems in the field (provided that service loads and temperature conditions are known), no direct correlation has yet been established. 5.7 This test method can be useful for evaluating the dynamic puncture resistance of membranes used in vegetative roof systems. SCOPE 1.1 This test method covers the evaluation of the dynamic puncture energy that roofing membrane specimens can withstand, without allowing the passage of water, when subjected to impact from a rigid object having a sharp edge. 1.2 This laboratory test can be conducted at any desired temperature using membrane specimens manufactured in a factory or prepared in a laboratory. 1.3 Roof membrane specimens to which the test method is applicable include bituminous built-up, polymer-modified bitumens, vulcanized rubbers, non-vulcanized polymeric, and thermoplastic materials. 1.3.1 The applicability of this test method to these membrane specimens includes their use in vegetative roof systems. 1.4 This test method is not applicable to aggregate-surfaced membrane specimens; however, it is applicable to specimens having factory-applied granules. 1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM D5635/D5635M-18(2022) is an internationally recognized standard developed by ASTM International that specifies a laboratory test method to evaluate the dynamic puncture resistance of roofing membrane specimens. The ability of roofing membranes to withstand puncture from sharp, rigid impacts is critical for the durability and waterproofing integrity of membrane roofing systems. This standard provides an objective, reproducible method to assess and compare the performance of various roofing membrane types, both as manufactured and as applied over insulation substrates under controlled conditions.
Key Topics
- Dynamic Puncture Resistance: The core focus is on evaluating how much dynamic, or impact, energy a roofing membrane can tolerate before being punctured, using a falling mass test device.
- Membrane Types: Applicable to bituminous built-up, polymer-modified bitumens, vulcanized rubbers, non-vulcanized polymeric, and thermoplastic roofing membranes. Excludes aggregate-surfaced membranes but includes factory-applied granule surfaces.
- Testing Conditions: The test can be performed at various controlled temperatures, helping to account for environmental factors that affect membrane performance.
- Comparative Assessment: Enables comparison among different membrane types on the same insulation or the same membrane over various insulations, supporting material selection and system design.
- Performance Criteria Development: The standard supports the development of performance classifications and criteria for roofing membranes, including those for vegetative (green) roofing systems.
- Non-quantitative Result: The outcome is a pass/fail depending on whether the specimen withstands the selected impact energy without water passage.
Applications
The ASTM D5635/D5635M-18(2022) test method is used in a range of practical scenarios, including:
- Material Evaluation: Manufacturers, designers, and contractors can assess and compare the puncture resistance of membrane roofing products under different conditions and insulation types.
- Product Classification: Supports developing specifications and classifications for roofing materials based on resistance to dynamic puncture impacts.
- Quality Assurance: Used by laboratories and quality control teams to verify that roofing membranes conform to project requirements or product standards for puncture resistance.
- Performance Specification: Designers can require minimum dynamic puncture resistance in project documentation, particularly for roofs subject to mechanical abuse, foot traffic, or installation of equipment.
- Vegetative Roof Systems: Especially relevant for green roofs, where membrane layers must withstand mechanical impacts from landscaping activities or heavy plant containers.
- Research and Development: Valuable for R&D purposes to optimize membrane formulations and roofing system designs for impact resistance.
Related Standards
For a holistic assessment and specification of roofing membranes, ASTM D5635/D5635M-18(2022) is typically referenced alongside other key industry standards, such as:
- ASTM C578: Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation, often used as the insulation substrate in dynamic puncture tests.
- ASTM D1079: Terminology Relating to Roofing and Waterproofing, ensuring common language and definitions in roofing practice.
- Other ASTM roofing test methods: Including standards covering tensile strength, elongation, water-tightness, and weather resistance.
Adopting and referencing ASTM D5635/D5635M in roofing projects supports compliance with international best practices and promotes long-term roof system performance.
Keywords: dynamic puncture resistance, roofing membrane, ASTM D5635, impact energy, insulation substrate, waterproofing, performance testing, vegetative roof systems, roofing standards, roof system durability
Технические детали
- Технический комитет
- D08 - Roofing and Waterproofing
- SKU
- ASTM D5635/D5635M-18(2022)
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…