ASTM D5810-96(2021) PDF
Standard Guide for Spiking into Aqueous Samples
Standard Guide for Spiking into Aqueous Samples
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 6
- Дата публикации:
- 1 июля 2021 г.
- Издание:
- D5810
- ICS:
- 19.020
SIGNIFICANCE AND USE 5.1 Matrix spiking is commonly used to determine the bias under specific analytical conditions, or the applicability of a test method to a particular sample matrix in that context, by determining the extent to which the spiked analyte or component is recovered from the sample matrix under these conditions. Reactions or interactions of the analyte or component of interest with the sample matrix may cause a significant positive or negative effect on recovery and may render the chosen analytical, or monitoring, process ineffectual for that sample matrix. 5.2 Matrix spiking can also be used to monitor the performance of a laboratory, individual instrument, or analyst as part of a regular quality assurance program. Changes in spike recoveries or recovery limits from the same or similar matrices over time may indicate variations in the quality of analytical results. 5.3 Spiking can be used to compare the recoveries of like spikes from reagent water samples and natural matrix samples (measured with and without spike) to distinguish between (1) unusual interference and (2) inherent method recovery and instability effects. This guide does not attempt to deal with the statistical significance of differences in spike recoveries from different matrices. 5.4 Special precautions shall be observed when nonlaboratory personnel perform spiking in the field. It is recommended that all spike preparation work be performed in a laboratory by experienced analysts so that the field operation consists solely of adding a prepared spiking solution to the sample matrix. Training of field personnel and validation of their spiking techniques are necessary to ensure that spikes are added accurately and reproducibly. Duplicate field spikes can be used to document the reproducibility of the technique. When environmentally labile compounds are used as spikes, the spiking solution shall be protected up to the point of use by appropriate means such as chilling, protection from sunlight and o... SCOPE 1.1 This guide covers the general technique of “spiking” a broad range of materials into aqueous media. This guide will serve the analyst in preparing spiked samples for quality control purposes. Guidance is also provided to aid the analyst in calculating recoveries and interpreting results. It is the responsibility of the analyst to determine whether the procedures and materials described here are appropriate to the task at hand. 1.2 The procedures in this guide are focused on “matrix spike” preparation, analysis, and interpretation of results. The applicability of these procedures to the preparation of calibration standards, calibration check standards, laboratory control standards, reference materials, and other quality control materials by spiking is incidental. A sample (the matrix) is fortified (spiked) with the analyte of interest for a variety of analytical and quality control purposes. While the spiking of multiple sample portions is discussed, the method of standard additions is not covered. 1.3 This guide is intended for use in conjunction with the individual analytical test method that provides procedures for analysis of the analyte or component of interest. The test method is used to determine an analyte or component’s background level and, again after spiking, its now elevated level. Each test method typically provides procedures not only for samples, but also for calibration standards or analytical control solutions, or both. These procedures include preparation, handling, storage, preservation, and analysis techniques. These procedures are applicable by extension, using the analyst’s judgement on a case-by-case basis, to spiking solutions, and are not reiterated in this guide. See also Practice E200 for preparation and storage information. 1.4 These procedures apply only to analytes that are soluble in water at the concentration of the spike plus any background material, or to analytes soluble in...
Abstract
Overview
ASTM D5810-96(2021), Standard Guide for Spiking into Aqueous Samples, published by ASTM International, provides comprehensive guidance on the practice of spiking known quantities of substances (analytes) into aqueous (water-based) samples. The primary aim is to support quality control and method validation in water analysis by evaluating matrix effects, analyte recovery, laboratory performance, and overall process reliability. This standard is widely recognized in water quality labs and environmental monitoring settings as a tool for method applicability and bias assessment, ensuring consistent data quality and robust analytical processes.
Key Topics
- Matrix Spiking Purpose: Explains how spiking is used to evaluate the recovery of analytes under specific analytical conditions, revealing possible matrix effects that can lead to positive or negative recovery biases.
- Quality Assurance: Highlights the role of matrix spiking in routine laboratory QA/QC programs by monitoring instrument, analyst, and laboratory performance over time.
- Field and Laboratory Spiking: Outlines protocols for both field and laboratory spiking, stressing the importance of proper procedure, thorough training, and solution handling to maintain reproducibility-especially when non-laboratory personnel are involved.
- Calculation and Interpretation: Provides guidance on calculating spiking recoveries and interpreting the results, including acceptable recovery ranges and the need to avoid correcting data directly with spike recoveries due to inherent differences.
- Reagent and Solution Preparation: Details requirements for purity, preparation, and stability verification of spiking solutions and solvents, emphasizing the use of high-purity reagents and strict storage protocols.
Applications
The ASTM D5810-96(2021) standard is applicable to a variety of scenarios in environmental and analytical laboratories working with water samples:
- Validation of Analytical Methods: Ensures that test methods are suitable for specific sample matrices, detecting any significant recovery losses or gains that may affect accuracy.
- Quality Control in Water Testing: Used routinely to assess and document the proficiency of instruments and analysts through ongoing recovery monitoring and control charting.
- Performance Evaluation: Enables differentiation between method-related limitations and unusual sample interferences by comparing spiking results from reagent water and actual sample matrices.
- Field Sampling Procedures: Guides preparation of field spikes for use in monitoring preservation and shipping effects, with protocols for maintaining sample and spike integrity.
- Interpretation of Analytical Bias: Facilitates the identification of matrix effects or analytical system bias, supporting corrective action in laboratory practices.
- Regulatory and Contract Laboratory Compliance: Meets expectations for data defensibility and traceability required by environmental regulations and laboratory accreditation bodies.
Related Standards
ASTM D5810-96(2021) interacts with and references other important ASTM and quality assurance standards, including:
- ASTM D1129 - Terminology Relating to Water
- ASTM D1193 - Specification for Reagent Water
- ASTM D3694 - Practices for Preparation of Sample Containers and Preservation of Organic Constituents
- ASTM D3856 - Guide for Management Systems in Laboratories Engaged in Water Analysis
- ASTM D4375 - Practice for Basic Statistics in Water Committee Work
- ASTM E200 - Practice for Preparation and Storage of Standard and Reagent Solutions
These supporting standards help ensure consistent sample preparation, reagent quality, laboratory practices, and statistical analysis across water testing laboratories.
Keywords: ASTM D5810, spiking into aqueous samples, matrix spike, water quality control, analyte recovery, laboratory QA/QC, method validation, analytical bias, environmental monitoring, water analysis standards.
Технические детали
- Технический комитет
- D19 - Water
- SKU
- ASTM D5810-96(2021)
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…