SIGNIFICANCE AND USE 5.1 Turbidity is undesirable in drinking water, plant effluent waters, water for food and beverage processing, and for a large number of other water-dependent manufacturing processes. Removal is often accomplished by coagulation, settling, and filtration. Measurement of turbidity provides a rapid means of process control for when, how, and to what extent the water must be treated to meet specifications. 5.2 This test method is suitable to turbidity such as that found in drinking water, process water, and high purity industrial water. 5.3 When reporting the measured result, appropriate units should also be reported. The units are reflective of the technology used to generate the result, and if necessary, provide more adequate comparison to historical data sets. 5.3.1 Table 1 describes technologies and reporting results (see also Refs (1-3)).6 Those technologies listed are appropriate for the range of measurement prescribed in this test method. Others may come available in the future. Fig. X5.1 provides a flow chart to aid in selection of the appropriate technology for low-level static turbidity applications. 5.3.2 If a design that falls outside of the criteria listed in Table 1 is used, the turbidity should be reported in turbidity units (TU) with a subscripted wavelength value to characterize the light source that was used. SCOPE 1.1 This test method covers the static determination of turbidity in water (see 4.1). 1.2 This test method is applicable to the measurement of turbidities under 5.0 nephelometric turbidity units (NTU). 1.3 This test method was tested on municipal drinking water, ultra-pure water, and low turbidity samples. It is the users responsibility to ensure the validity of this test method for waters of untested matrices. 1.4 This test method uses calibration standards are defined in NTU values, but other assigned turbidity units are assumed to be equivalent. 1.5 This test method assigns traceable reporting units to the type of respective technology that was used to perform the measurement. Units are numerically equivalent with respect to the calibration standard. For example, a 1.0 NTU formazin standard is also equal to a 1.0 FNU standard, a 1.0 FNRU standard, and so forth. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this test method. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM D6855-17(2023) is a standard test method developed by ASTM International for the static determination of turbidity levels below 5 Nephelometric Turbidity Units (NTU) in water samples. Turbidity, an optical property caused by suspended and dissolved matter in water, is a key indicator of water quality. This standard is essential for applications involving drinking water, process water, and high-purity industrial water where low turbidity levels are desired. By specifying reliable methods for measurement and calibration, ASTM D6855-17(2023) ensures rapid and accurate turbidity assessment, enabling effective process control and compliance with regulatory standards.
Key Topics
-
Applicability and Scope
- Suitable for measuring turbidity below 5.0 NTU in static water samples.
- Applies to municipal drinking water, ultra-pure water, and low turbidity samples.
- Calibration is based on NTU values, with equivalency for other accepted turbidity units.
-
Measurement Principles
- Turbidity is determined using nephelometric methods, measuring the intensity of light scattered at a 90° angle from the incident light path.
- The test method outlines requirements for instrumentation, including nephelometers and ratio nephelometers.
-
Calibration and Reporting
- Calibration uses traceable standards, such as formazin.
- Results must be reported with appropriate units, reflective of the measurement technology (e.g., NTU, FNU, FNRU).
- Provides guidance for using alternative designs, requiring transparent reporting of wavelength and units for comparability.
-
Quality Assurance
- Recommends rigorous calibration, verification, and quality control procedures.
- Emphasizes proper sample handling, cell cleanliness, and avoidance of interferences (such as bubbles, color, and large particles) for data reliability.
Applications
-
Drinking Water Quality Monitoring
- Ensures water meets regulatory turbidity limits, contributing to public health and safety.
- Facilitates compliance with EPA Method 180.1 and ISO 7027, both referenced for regulatory purposes.
-
Process Control in Industry
- Used in water treatment facilities to adjust operations (coagulation, settling, filtration) based on real-time turbidity feedback.
- Vital for food and beverage manufacturing where product quality depends on low-turbidity water.
-
High-Purity and Ultra-Pure Water Systems
- Supports water-dependent processes in electronics, pharmaceuticals, and laboratories where even low levels of turbidity can impact product outcome.
-
Environmental Compliance
- Provides a rapid assessment tool for regulatory and internal audits of effluent and surface waters, supporting sustainability practices and environmental stewardship.
Related Standards
- ASTM D1129 - Terminology Relating to Water
- ASTM D1193 - Specification for Reagent Water
- ASTM D3370 - Practices for Sampling Water from Flowing Process Streams
- ASTM D5847 - Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis
- ASTM D7315 - Test Method for Determination of Turbidity Above 1 Turbidity Unit in Static Mode
- EPA Method 180.1 - Chemical Analysis of Water and Wastes: Turbidity
- ISO 7027 - Water Quality - Determination of Turbidity
Practical Value
Implementing ASTM D6855-17(2023) helps organizations standardize low-level turbidity measurements, improving water quality management and compliance. Its procedures support the use of current and emerging technologies, ensuring traceable, reliable results. Adherence to this standard helps industries maintain quality control, regulatory adherence, and operational efficiency while protecting water resources.
Keywords: ASTM D6855-17(2023), turbidity measurement, low turbidity water, nephelometric method, drinking water quality, process water, water analysis standard, formazin standard, EPA Method 180.1, ISO 7027, water treatment compliance, industrial water quality.
Технические детали
- Технический комитет
- D19 - Water
- SKU
- ASTM D6855-17(2023)
Похожие стандарты
Упомянутые в описании и другие стандарты ASTM
ISO 7027-1:2016
ДействующийWater quality — Determination of turbidity — Part 1: Quantitative methods
Overview ISO 7027-1:2016 - "Water quality - Determination of turbidity - Part 1: Quantitative methods" - defines standard quantitative procedures for measuring turbidity in water using optical nephel…
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…