ASTM D8429-21 PDF
Standard Test Method for Legionella pneumophila in Water Samples Using Legiolert
Standard Test Method for Legionella pneumophila in Water Samples Using Legiolert
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 1 декабря 2021 г.
- Издание:
- D8429
- ICS:
- 07.100.20
SIGNIFICANCE AND USE 5.1 This test provides an easy and reliable method for the detection of L. pneumophila in potable and non-potable waters in 7 days. 5.2 Routine monitoring for L. pneumophila determines whether implemented control measures are effective, such as those outlined in a water safety program (2). 5.2.1 Water system management is necessary to maintain L. pneumophila concentrations below hazardous levels. Through routine measurement of L. pneumophila levels, a monitoring program can ensure that control measures are effective and implemented when necessary in response to increasing levels. Water samples may be examined for L. pneumophila during epidemiological investigations as part of local authority, industrial, or hospital programs, or in order to validate treatment control methods. Routine sampling could also be carried out based on risk assessments or on local, state, or federal requirements or guidelines. SCOPE 1.1 This test method describes a simple procedure for the detection of Legionella pneumophila (L. pneumophila) in potable water and non-potable waters (cooling towers, for example). This procedure describes a liquid culture method based on a bacterial enzyme technology. The detection of L. pneumophila is signaled through the utilization of a substrate present in the Legiolert reagent. L. pneumophila cells grow rapidly and reproduce using the rich supply of amino acids, vitamins and other nutrients present in the Legiolert reagent. Actively growing strains of L. pneumophila use the added substrate to produce a brown color indicator or produce turbid growth with or without brown coloration. Legiolert can detect this bacterial species at the following minimum concentrations based on the protocol employed: 1.1.1 Potable Water: 1.1.1.1 ≥1 organism / 100 mL at 7 days for 100 mL potable protocol. 1.1.1.2 ≥1 organism / 10 mL at 7 days for 10 mL potable protocol. 1.1.2 Non-potable Water: 1.1.2.1 ≥1 organism / 1.0 mL at 7 days for 1.0 mL non-potable protocol. 1.1.2.2 ≥1 organism / 0.1 mL at 7 days for 0.1 mL non-potable protocol. 1.1.3 This test method can be used for potable (drinking) waters and non-potable waters such as cooling tower waters (1).3 It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM D8429-21 is the standard test method for the detection of Legionella pneumophila in water samples using the Legiolert system. Developed by ASTM International, this test method provides a straightforward and efficient protocol for identifying L. pneumophila in both potable (drinking) and non-potable waters, such as cooling towers. The method uses a liquid culture approach based on bacterial enzyme technology and the Legiolert reagent, delivering results within 7 days. It supports water safety management programs and compliance with health regulations by enabling reliable routine monitoring of this key waterborne pathogen.
Key Topics
- Legionella pneumophila Detection: Employs Legiolert, which signals the presence of L. pneumophila through a substrate reaction in the reagent, indicated by brown coloration and/or turbidity.
- Applicability: Effective for potable water at minimum concentrations of ≥1 organism/100 mL (100 mL protocol) or ≥1 organism/10 mL (10 mL protocol), and for non-potable water at ≥1 organism/1.0 mL or 0.1 mL, based on the respective protocol.
- Most Probable Number (MPN): Utilizes the Quanti-Tray/Legiolert system for quantification, providing statistically robust enumeration of L. pneumophila per sample volume.
- Routine Monitoring: Facilitates continuous assessment of water systems, verifying the effectiveness of implemented control measures outlined in water safety programs.
- Epidemiological Use: Suitable for outbreak investigations and validation of water treatment processes by public health authorities, hospitals, and industrial operators.
- Risk-Based Sampling: Supports sampling strategies based on site-specific risk evaluations and adherence to local, state, or federal guidelines.
- Safety and Precaution: Users must employ appropriate laboratory biosafety practices (minimum BSL-2), especially when working with pathogenic bacteria and potentially aerosol-generating procedures.
Applications
ASTM D8429-21 is integral to public health, industrial hygiene, and regulatory compliance due to its utility in:
- Drinking Water Surveillance: Enables water utilities and facilities to monitor potable water supplies for L. pneumophila, protecting public health.
- Cooling Tower and Industrial Water Management: Supports safe operation of industrial water systems such as cooling towers, spas, and fountains by early detection of L. pneumophila contamination.
- Healthcare Water Safety Programs: Assists hospitals and long-term care facilities in routine surveillance to mitigate risks associated with Legionnaire’s disease.
- Outbreak Investigation: Used by local and federal health authorities for rapid response and root cause analysis during outbreaks linked to water systems.
- Compliance Verification: Helps organizations comply with operational, state, and federally-mandated water quality requirements by providing a validated, standardized detection method.
Related Standards
Understanding and implementing ASTM D8429-21 is complemented by referencing the following standards and guidelines:
- ASTM D1129: Terminology Relating to Water
- ASTM D1193: Specification for Reagent Water
- ASTM D2777: Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
- ASTM D3370: Practices for Sampling Water from Flowing Process Streams
- ASTM D5952: Guide for the Inspection of Water Systems for Legionella and the Investigation of Possible Outbreaks of Legionellosis
- ASTM D6503: Test Method for Enterococci in Water Using Enterolert
- World Health Organization & CDC Guidance: Additional biosafety and water quality recommendations
ASTM D8429-21 is essential for organizations aiming to maintain water system safety and minimize health risks associated with Legionella pneumophila. Its straightforward, reliable approach using Legiolert helps meet regulatory expectations, supports outbreak prevention, and underpins effective water safety management.
Технические детали
- Технический комитет
- D19 - Water
- SKU
- ASTM D8429-21
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…