ASTM E1683-02(2022) PDF
Standard Practice for Testing the Performance of Scanning Raman Spectrometers
Standard Practice for Testing the Performance of Scanning Raman Spectrometers
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 6
- Дата публикации:
- 15 декабря 2022 г.
- Издание:
- E1683
- ICS:
- 71.040.50
SIGNIFICANCE AND USE 4.1 A scanning Raman spectrometer should be checked regularly to determine if its condition is adequate for routine measurements or if it has changed. This practice is designed to facilitate that determination and, if performance is unsatisfactory, to identify the part of the system that needs attention. These tests apply for single-, double-, or triple-monochromator scanning Raman instruments commercially available. They do not apply for multichannel or Fourier transform instruments, or for gated integrator systems requiring a pulsed laser source. Use of this practice is intended only for trained optical spectroscopists and should be used in conjunction with standard texts. SCOPE 1.1 This practice covers routine testing of scanning Raman spectrometer performance and to assist in locating problems when performance has degraded. It is also intended as a guide for obtaining and reporting Raman spectra. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautions, see 7.2.1. 1.4 Because of the significant dangers associated with the use of lasers, ANSI Z136.1 should be followed in conjunction with this practice. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM E1683-02(2022): Standard Practice for Testing the Performance of Scanning Raman Spectrometers is an internationally recognized standard published by ASTM International. This document provides guidance for routine testing of the performance of scanning Raman spectrometers, covering procedures to evaluate instrument condition, troubleshooting methods when performance degradation is identified, and best practices for obtaining and reporting Raman spectra.
This practice is specifically applicable to single-, double-, or triple-monochromator scanning Raman instruments and is intended for use by trained optical spectroscopists. It does not apply to multichannel, Fourier transform instruments, or systems requiring a pulsed laser source. Adherence to this standard helps laboratories ensure the ongoing reliability and accuracy of their Raman spectroscopy results, supporting both research and industrial applications.
Key Topics
- Performance Evaluation: Provides techniques to regularly verify whether a scanning Raman spectrometer functions as expected for routine measurements and to identify affected system components if the instrument's condition changes.
- Instrument Testing Procedures: Details step-by-step methods for assessing core elements including laser sources, monochromators, photomultiplier tubes, and sampling optics.
- Calibration Guidance: Describes how to calibrate spectrometers using standard emission sources to check wavenumber accuracy and spectral response.
- Recording and Reporting Raman Spectra: Outlines best practices for recording spectra using various data acquisition systems and emphasizes comprehensive documentation of experimental conditions.
- Troubleshooting and Problem Identification: Recommends specific materials, such as carbon tetrachloride and cyclohexane, for use as test samples in verifying performance and isolating malfunctions within the spectrometer.
- Safety Considerations: Stresses the need to establish appropriate safety, health, and environmental procedures, especially regarding laser use, in accordance with ANSI Z136.1.
Applications
The primary application of ASTM E1683-02(2022) is the quality assurance and maintenance of scanning Raman spectrometers in laboratory settings. Key practical benefits include:
- Routine Instrument Verification: Ensures that Raman spectrometers maintain their performance standards over time, minimizing errors in spectral data.
- Instrument Calibration: Provides a standardized approach for calibrating wavenumber scales and spectral responses, increasing the accuracy and comparability of Raman spectra between laboratories.
- Troubleshooting Tool: Offers systematic steps to identify performance issues, reducing downtime and helping users make informed maintenance or service decisions.
- Support for Data Integrity: Promotes comprehensive reporting of all conditions and parameters related to Raman measurements, which is crucial for transparency, validation, and reproducibility in both research and industrial quality control.
- Enhanced Instrument Safety: Reinforces the importance of following laser safety guidelines to protect personnel and maintain a safe laboratory environment.
Related Standards
- ASTM E131: Terminology Relating to Molecular Spectroscopy - Provides standard definitions used throughout the field of molecular spectroscopy.
- ASTM E1840: Guide for Raman Shift Standards for Spectrometer Calibration - Offers specific reference materials and procedures for calibrating Raman shift accuracy.
- ANSI Z136.1: Safe Use of Lasers - Establishes safety requirements for control of laser hazards, which must be followed alongside this standard.
- IUPAC Recommendations: Guidelines for the presentation and data reporting of Raman spectra in scientific publications.
Summary
By implementing ASTM E1683-02(2022), organizations can ensure the sustained accuracy, reliability, and safety of their scanning Raman spectrometers, facilitating high-quality Raman spectroscopy analysis in diverse research and industrial settings. This standard is an essential resource for laboratories and professionals seeking a comprehensive, internationally recognized framework for Raman spectrometer maintenance and performance validation.
Технические детали
- Технический комитет
- E13 - Molecular Spectroscopy and Separation Science
- SKU
- ASTM E1683-02(2022)
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…