ASTM F2407/F2407M-23a PDF
Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities
Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 11
- Дата публикации:
- 1 июня 2023 г.
- Издание:
- F2407/F2407M
- ICS:
- 11.140
ABSTRACT This specification establishes the requirements for the performance, documentation, and labeling of surgical gowns used in the healthcare facilities. It does not however cover all the requirements that a healthcare facility deems necessary to select a product, nor does it address criteria for evaluating experimental products. Barrier testing shall be conducted to determine the impact penetration, hydrostatic resistance, and viral penetration resistance performance of the critical zone(s) of the surgical gown. The physical properties of the critical zone(s) of the surgical gown shall also be tested and shall conform to the following requirements: tensile strength, tear resistance, seam strength, lint generation, evaporative resistance, and water vapor transmission rate. General safety requirements shall be set based on biocompatibility, sterility assurance, flame spread, and natural rubber latex specifications. SIGNIFICANCE AND USE 4.1 This specification provides minimum requirements for surgical gowns used for protection of healthcare workers where the potential for exposure to blood, body fluids, and other potentially infectious materials exists. The specification requires barrier testing based on the system of classifying gowns established in ANSI/AAMI PB70 and sets general safety requirements for surgical gowns based on biocompatibility, sterility assurance, and flame spread. Performance requirements are established for important physical properties, including tensile strength, tear strength, and seam strength. Methods to be used for optional reporting of performance of linting resistance, evaporative resistance, water vapor transmission rate, and abrasion resistance are provided. 4.2 This specification does not address protective clothing used for nonsurgical applications, such as isolation gowns or decontamination gowns; protective clothing for the hands, such as surgical gloves, patient examination gloves, or other medical gloves; protective clothing for the head, such as goggles or face shields, surgical caps or hoods, surgical masks, or respirators; protective clothing for the feet, such as operating room shoes, shoe covers, or surgical boots; or other types of protective clothing and equipment worn by healthcare providers. 4.3 Surgical gowns are either multiple-use or single-use products as designated by the manufacturer. This specification is intended to provide the basis for manufacturer claims for surgical gown performance and efficacy. For multiple-use gowns, this specification takes into account the anticipated care and maintenance of these products by examining test requirements for surgical gown materials both before and after the maximum expected number of cycles for laundering and sterilization. 4.4 Additional information on the processing of multiple-use surgical gowns is provided in ANSI/AAMI ST65. 4.5 While surgical gowns are classified for barrier performance... SCOPE 1.1 This specification establishes requirements for the performance, documentation, and labeling of surgical gowns used in healthcare facilities. Four levels of barrier properties for surgical gowns are specified in ANSI/AAMI PB70 and are included in this specification for reference purposes. Note 1: Some properties require minimum performance and others are for documentation only. Note 2: ANSI/AAMI PB70 evaluates the barrier properties of surgical gown fabrics using water only in Levels 1, 2, and 3. Since surgical gowns are exposed to blood and other fluids with different surface tensions, the performance of additional testing to identify the barrier levels to simulated biological fluids is required for a Level 4 gown. 1.2 This specification does not cover all the requirements that a healthcare facility deems necessary to select a product, nor does it address criteria for evaluating experimental products. 1.3 This specification is not intended to serve as a detailed manufacturing or purchase...
Похожие стандарты
Упомянутые в описании и другие стандарты ASTM