ASTM F2618-24 PDF
Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Fittings for Chemical Waste Drainage Systems
Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Fittings for Chemical Waste Drainage Systems
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 8
- Дата публикации:
- 1 апреля 2024 г.
- Издание:
- F2618
- ICS:
- 23.040.20
SCOPE 1.1 This specification covers the performance requirements of CPVC pipe, fittings and solvent cements used in chemical waste drainage systems. 1.2 A system is made up of pipe, fittings and solvent cement that meet the requirements of this standard. Note 1: Consult the manufacturer’s chemical resistance recommendations for chemical waste drainage applications prior to use. 1.3 The text of this specification references notes, footnotes and appendices that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.4 The pressure tests described in this standard are laboratory hydrostatic tests that are intended to verify joint/system integrity. They are not intended for use as field tests of installed systems. 1.5 Due to inherent hazards associated with testing components and systems with compressed air or other compressed gases, no such testing shall be done unless the component manufacturer gives approval in writing. Note 2: Pressurized (compressed) air or other compressed gases contain large amounts of stored energy, which present serious safety hazards should a system fail for any reason. 1.6 Mechanical joints used for joining pipe and fittings of different materials are provided for in this specification. They include common flanges, couplings, and unions. 1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 3: This specification specifies dimensional, performance, and test requirements for fluid handling applications but does not address venting of combustion gases. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Abstract
Overview
ASTM F2618-24 specifies the performance requirements for chlorinated poly (vinyl chloride) (CPVC) pipe, fittings, and solvent cements intended for use in chemical waste drainage systems. Developed by ASTM International, this standard ensures the quality, durability, and chemical resistance of CPVC piping systems designed specifically for the transport and disposal of corrosive waste liquids in laboratory or industrial environments. It covers physical properties, material requirements, joint integrity, dimensional tolerances, product marking, and installation guidance, providing confidence in the safe application of CPVC piping for chemical waste drainage.
Key Topics
- Material Requirements: CPVC compounds used must meet stringent classification standards to deliver chemical resistance, homogeneity, and durability.
- Performance Testing: Laboratory hydrostatic pressure tests verify the integrity of both solvent-cemented and mechanical joints.
- Chemical Compatibility: Users should consult manufacturers for recommendations regarding chemical resistance to ensure material suitability.
- Dimensional Standards: Pipe sizes, wall thicknesses, and fitting dimensions are carefully controlled for consistent system performance.
- Joint Methods: Includes solvent cementing, mechanical joining (flanges, couplings, unions), and proper use of thread sealants, gaskets, and seals.
- Product Marking: Pipes and fittings require permanent, legible markings, indicating manufacturer, material, nominal size, CPVC-CW designation, and ASTM F2618 compliance.
- Solvent Cement Specifications: Cements must meet requirements for color, viscosity, and safe use; flammable components necessitate proper handling.
- Installation Guidance: Recommendations for storage, assembly, support, and alignment help ensure system safety and long-term performance.
Applications
CPVC pipe and fittings for chemical waste drainage systems are ideally suited for:
- Laboratories: Safely conveying acidic, caustic, or otherwise corrosive chemical waste fluids in academic, research, and industrial labs.
- Industrial Waste Systems: Handling chemical discharge in manufacturing, processing plants, or facilities where chemical resistance is paramount.
- Specialty Drainage: Used in commercial and institutional buildings where aggressive waste streams exceed the capabilities of standard PVC or metal piping.
- Retrofit and New Construction: Applicable for both new installations and upgrades to existing chemical waste drainage systems, ensuring code compliance and reliability.
- Building Services: Integration with other plumbing and mechanical systems for the transport of hazardous fluids, provided that chemical compatibility is verified.
Related Standards
Several other standards are referenced and integrated with ASTM F2618-24 to ensure complete system quality and compatibility:
- ASTM D1784: Specifies the classification system for rigid PVC and CPVC compounds.
- ASTM D2122: Provides test methods for determining dimensions of thermoplastic pipe and fittings.
- ASTM D543: Details practices for evaluating the chemical resistance of plastics.
- ASTM F493: Covers requirements for solvent cements used with CPVC pipe and fittings.
- ASTM F1498: Specifies taper pipe threads for thermoplastic pipes and fittings.
- ASTM D3311, F2135: Define patterns for DWV plastic fittings.
- Codes and Regulations: Installations should comply with applicable versions of the International and Uniform Plumbing Codes, as well as Federal Standard 123 and MIL-STD-129 for marking and shipping when relevant.
Practical Value
By adhering to the ASTM F2618-24 standard, engineers, contractors, and facility operators ensure the safety, reliability, and chemical compatibility of CPVC waste piping systems. Its rigorous requirements help prevent leakage, system failure, and hazardous exposure, making it a trusted choice for environments where chemical waste drainage is critical.
Технические детали
- Технический комитет
- F17 - Plastic Piping Systems
- SKU
- ASTM F2618-24
Похожие стандарты
Другие стандарты ASTM
ASTM-TPT-47
Phase I & Phase II Environmental Site Assessment Processes
Phase I & Phase II Environmental Site Assessment Processes
ASTM-TPT-8
Phase I Environmental Site Assessment Practices For Commercial Real Estate: Phase I Site Assessment & Transac…
ASTM-TPT-1137
ASTM D975 Standard Specification for Diesel Fuel
ASTM D975 Standard Specification for Diesel Fuel
ASTM-TPT-1202
ASTM D8421 Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Ma…
ASTM D8421 Standard Test Method -- eLearning Course
ASTM-TPT-691
Microaprendizagem para D4057: Amostragem de ponto (PT)
D4057 Microlearning: Spot Sampling Portuguese
ASTM-TPT-1091
Metodo de prueba estandar D4052 de ASTM -- Curso de aprendizaje electrónico (ES)
Modulo eLearning para ASTM D4052 en espanol
ASTM ACEM20180086
Using Neutron Radiography to Quantify the Settlement of Fresh Concrete
Specifications have been implemented for concrete bridge decks in North America that restrict the use of higher slump concrete mixtures primarily because of concerns about differential settlement and…
ASTM ACEM20180041
Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concret…