ASTM ISO/ASTM51538-09 PDF
Standard Practice for Use of the Ethanol-Chlorobenzene Dosimetry System
Standard Practice for Use of the Ethanol-Chlorobenzene Dosimetry System
- Статус документа:
- D
- Формат:
- Электронный (PDF)
- Количество страниц:
- 11
- Дата публикации:
- 22 января 2002 г.
- Издание:
- ISO/ASTM51538
- ICS:
- 17.240
SIGNIFICANCE AND USE 4.1 The ECB dosimetry system provides a reliable means of measuring absorbed dose in materials. It is based on a process of radiolytic formation of hydrochloric acid (HCl) in aqueous ethanolic solutions of chlorobenzene by ionizing radiation (7,8). 4.2 The dosimeters are partly deoxygenated solutions of chlorobenzene (CB) in 96 volume % ethanol in an appropriate container, such as a flame-sealed glass ampoule. The irradiated solutions indicate absorbed dose by the amount of HCl formed. Anumber of analytical methods are available for measuring the amount of HCl in ethanol (9). 4.3 Effect of Irradiation Temperature: 4.3.1 The temperature dependence of dosimeter response is a complex function of dose and temperature for each concentration of chlorobenzene (that is, for each formulation). The analysis of the published data (10) shows that the temperature dependence between 20°C and 80°C at any chlorobenzene concentration can be described by a simple exponential expression: Gt 5 G0 exp[k~t 2 20!# (3) where: Gt = the radiation chemical yield in μmol J−1 at a given temperature t in °C, G0 = the radiation chemical yield in μmol J−1 at 20°C ((G0 for different ECB solutions are given in Table 1), and k = the temperature coefficient in (°C)−1 applicable at a given dose. 4.3.2 The values of k are given in Table 2. 4.3.3 Between −30°C and 50°C the temperature coefficient 0.015 kGy/°C applies at 30 kGy dose (12). Information on the temperature dependence of dosimeter response during irradiation between 20 and 80°C is found in Ref (10), and between −40 and 20°C in Ref (13). 4.4 The concentration of chlorobenzene in the solution can be varied so as to simulate a number of materials in terms of the photon mass energy-absorption coefficients (μen/r) for X and gamma radiation, and electron mass collision stopping powers (S/r), over a broad energy range from 10−2 to 100 MeV(14-17). 4.5 The absorbed dose that is determined is the dose absorbed in the water. Absorbed dose i... SCOPE 1.1 This practice covers the preparation, handling, testing, and procedure for using the ethanol-chlorobenzene dosimetry system to measure absorbed dose in materials irradiated by photons and electrons in terms of absorbed dose in water. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the ECB system. It is classified as a reference-standard dosimeter and is also used as a routine dosimetry system (see ISO/ASTM Guide 51261). 1.2 This practice describes the titration analysis as a standard readout procedure for the ECB dosimeter. Other applicable readout methods (spectrophotometric, oscillometric) are described in Annex A1 and Annex A2. 1.3 This practice applies only to gamma rays, X rays, and high-energy electrons. 1.4 This practice applies provided the following are satisfied: 1.4.1 The absorbed dose range shall be from 10 Gy to 2 MGy (1). 1.4.2 The absorbed dose rate does not exceed 10 6 Gy s1 (2). 1.4.3 For radionuclide gamma-ray sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be equal to or greater than 4 MeV (3) (see ICRU Reports 34 and 35). Note 1—The lower limits of electromagnetic radiation energy given are appropriate for a cylindrical dosimeter ampoule of 12-mm diameter. Corrections for dose gradients across an ampoule of that diameter or less are not required. The ECB system may be used at energies of incident electrons lower than 4 MeV by employing thinner (in the beam direction) dosimeter containers (see ICRU Report 35). The ECB system may also be used at X-ray energies as low as 120 kVp (4). In this range of photon energies the effect caused by the wall is considerable. 1.4.4 The irradiation temperature ...
Технические детали
- Технический комитет
- E61 - Radiation Processing
- SKU
- ASTM ISO/ASTM51538-09
Похожие стандарты
Другие стандарты ASTM