ASTM ISO/ASTM51939-22 PDF
Standard Practice for Blood Irradiation Dosimetry
Standard Practice for Blood Irradiation Dosimetry
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 13
- Дата публикации:
- 1 декабря 2022 г.
- Издание:
- ISO/ASTM51939
- ICS:
- 11.040.20
SIGNIFICANCE AND USE 4.1 Blood and blood components are irradiated to predetermined absorbed doses to inactivate viable lymphocytes to help prevent transfusion-induced graft-versus-host disease (GVHD) in certain immunocompromised patients and those receiving related-donor products (1, 2).9 4.2 The assurance that blood and blood components have been properly irradiated is of crucial importance for patient health. This shall be demonstrated by means of accurate absorbed-dose measurements on the product, or in simulated product. 4.3 Blood and blood components are usually irradiated using gamma radiation from 137Cs or 60Co sources, or X-radiation from X-ray units. 4.4 Blood irradiation specifications include a lower limit of absorbed dose, and may include an upper limit or central target dose. For a given application, any of these values may be prescribed by regulations that have been established on the basis of available scientific data (see 2.6). 4.5 For each blood irradiator, an absorbed-dose rate at a reference position within the canister is measured as part of irradiator acceptance testing using a reference-standard dosimetry system. That reference-standard measurement is used to establish operating parameters so as to deliver specified dose to blood and blood components. 4.6 Absorbed-dose measurements are performed within the blood or blood-equivalent volume for determining the absorbed-dose distribution. Such measurements are often performed using simulated product (for example, polystyrene is considered blood equivalent for 137Cs photon energies). 4.7 Dosimetry is part of a measurement management system that is applied to ensure that the radiation process meets predetermined specifications (see ISO/ASTM Practice 52628). 4.8 Blood and blood components are usually irradiated in chilled or frozen condition. Care should be taken, therefore, to ensure that the dosimeters and radiation-sensitive indicators can be used under such temperature conditions. 4.9 Proper ... SCOPE 1.1 This practice outlines the irradiator installation qualification program and the dosimetric procedures to be followed during operational qualification and performance qualification of the irradiator. Procedures for the routine radiation processing of blood product (blood and blood components) are also given. If followed, these procedures will help ensure that blood product exposed to gamma radiation or X-radiation (bremsstrahlung) will receive absorbed doses with a specified range. 1.2 This practice covers dosimetry for the irradiation of blood product for self-contained irradiators (free-standing irradiators) utilizing radionuclides such as 137Cs and 60Co, or X-radiation (bremsstrahlung). The absorbed dose range for blood irradiation is typically 15 Gy to 50 Gy. 1.3 The photon energy range of X-radiation used for blood irradiation is typically from 40 keV to 300 keV. 1.4 This practice also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the product has been irradiated (see ISO/ASTM Guide 51539). 1.5 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing and describes a means of achieving compliance with the requirements of ISO/ASTM Practice 52628 for dosimetry performed for blood irradiation. It is intended to be read in conjunction with ISO/ASTM Practice 52628. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides ...
Abstract
Overview
ASTM ISO/ASTM51939-22: Standard Practice for Blood Irradiation Dosimetry is a globally recognized document that outlines best practices for the dosimetry associated with the irradiation of blood and blood components. Issued by ASTM, this standard ensures that blood irradiation processes meet strict safety and quality requirements, primarily aiming to inactivate viable lymphocytes and prevent transfusion-induced graft-versus-host disease (GVHD) in vulnerable patient populations. The standard covers dosimetric qualification programs, calibration, installation, and quality assurance for irradiators using radionuclides such as Cesium-137 (137Cs), Cobalt-60 (60Co), or X-ray units.
Key Topics
- Purpose of Blood Irradiation: Blood and blood components must be exposed to precise absorbed radiation doses to inactivate lymphocytes and reduce GVHD risk in immunocompromised patients or recipients of related-donor transfusions.
- Importance of Accurate Dosimetry: Assuring that irradiation is performed correctly is critical for patient health and regulatory compliance. Proper documentation and measurement of absorbed dose must be maintained.
- Types of Irradiators: The standard details the use of self-contained gamma irradiators (often utilizing 137Cs or 60Co) as well as X-ray (bremsstrahlung) units within a typical photon energy range of 40 keV to 300 keV.
- Dose Specifications: Blood irradiation protocols require a controlled dose, usually between 15 Gy and 50 Gy, with lower and possibly upper dose limits stipulated by scientific data or regulation.
- Dosimetry Systems: The practice distinguishes between reference-standard dosimetry systems (used for calibration) and routine dosimetry systems (used for process monitoring and dose mapping). It includes the requirement for calibration traceable to national or international standards.
- Indicators and Monitoring: Use of radiation-sensitive indicators is included for visual confirmation of irradiation. Regular absorbed-dose mapping and monitoring of the irradiation process are called for.
- Environmental Considerations: Dosimeters and indicators must function reliably under chilled or frozen temperatures, as blood products are commonly irradiated in these conditions.
- Quality and Documentation: The standard underlines the importance of robust measurement management, installation qualification, operational and performance qualification, and documentation of all processes.
Applications
Hospitals, Blood Banks, and Transfusion Services
- Patient Safety: Ensures irradiated blood and blood components consistently receive the prescribed dose to prevent GVHD, thereby enhancing transfusion safety for at-risk patients.
- Regulatory Compliance: Meets regulatory expectations by documenting and controlling irradiation processes, as required by professionals in transfusion medicine.
- Quality Control: Provides a framework for ongoing equipment calibration, operational qualification, and periodic performance evaluation to maintain process integrity.
Medical Device Manufacturers
- Irradiator Qualification: Guides installation and operational qualification protocols for new or existing blood irradiators.
- Product Documentation: Assists manufacturers in developing compliant documentation and processes in accordance with international dosimetry standards.
Accreditation and Inspection
- Traceability: Promotes laboratory practices that are traceable to national or international measurement standards.
- Audit Readiness: Ensures all activities, from dosimeter calibration to absorbed-dose mapping and recordkeeping, are auditable and meet international best practices.
Related Standards
For comprehensive quality management and regulatory compliance in blood irradiation dosimetry, the following standards and guides are frequently referenced:
- ISO/ASTM 52628: Dosimetry in Radiation Processing - General requirements and compliance.
- ISO/ASTM 51026: Practice for Using the Fricke Dosimetry System.
- ISO/ASTM 51539: Guide for the Use of Radiation-Sensitive Indicators.
- ISO/ASTM 51956: Practice for Use of Thermoluminescence-Dosimetry Systems (TLD Systems) for Radiation Processing.
- ISO/ASTM 52116: Dosimetry for Self-Contained Dry-Storage Gamma-Ray Irradiators.
- ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories.
ASTM ISO/ASTM51939-22 is an essential tool for healthcare providers, quality assurance professionals, and regulatory authorities seeking to ensure safe, effective, and standardized blood irradiation practices worldwide. Leveraging these guidelines helps protect patient health, demonstrate compliance, and uphold the highest standards in blood product processing.
Технические детали
- Технический комитет
- E61 - Radiation Processing
- SKU
- ASTM ISO/ASTM51939-22
Похожие стандарты
Стандарты, упомянутые в описании
ASTM ISO/ASTM51026-15
Standard Practice for Using the Fricke Dosimetry System
ASTM52116-26
ДействующийStandard Practice for Dosimetry for a Self-Contained Dry-Storage Gamma Irradiator
Significance and Use4.1 The design and operation of a self-contained irradiator should ensure that reproducible absorbed doses are obtained when the same irradiation parameters are used. Dosimetry is…
ISO 6141:2015/Amd 1:2020
ДействующийGas analysis — Contents of certificates for calibration gas mixtures — Amendment 1: Cross reference list to I…
Overview ISO 6141:2015/Amd 1:2020 is an important amendment to the international standard ISO 6141:2015, which specifies the contents of certificates for calibration gas mixtures used in gas analysis…