BS EN 62838:2016 PDF
LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. Safety specifications
LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. Safety specifications
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Дата публикации:
- 31 марта 2018 г.
- ICS:
- 29.140.01
- SKU:
- BS EN 62838:2016
Abstract
1 Scope This International Standard specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show compliance of LED lamps with integrated means for stable operation, intended for domestic and similar general lighting purposes, having:
— a rated power up to 60 W
— a rated voltage equal to or less than 50 V a.c. r.m.s. or equal or less 120 V ripple free d.c.,
— caps according to Table 1.
NOTE 1 The value of 60 W rated power is under consideration. Heat management may require lower power.
This standard shall be used for products in conjunction with ELV lighting installations. With reference to IEC 60364‑7‑715, in ELV lighting installations only SELV sources are applied. Where bare conductors are used, the maximum lamp voltage shall be 25 V a.c. or 60 V d.c. The requirements of this standard relate only to type testing. For lamps > 25 V a.c. or 60 V d.c., recommendations for whole production testing or batch testing are given in IEC 60598‑1 Table Q.1, column class III luminaire, column 4 or 5.
NOTE 2 Where in this standard the term ��...
Похожие стандарты
Упомянутые в описании и другие стандарты BS