IEC 60051-5:2017
Direct acting indicating analogue electrical measuring instruments and their accessories - Part 5: Special requirements for phase meters, power factor meters and synchroscopes
Direct acting indicating analogue electrical measuring instruments and their accessories - Part 5: Special requirements for phase meters, power factor meters and synchroscopes
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 32
- Дата публикации:
- 15 декабря 2017 г.
- Издание:
- IEC IS 60051 edition 5 version 1
- ICS:
- 17.220.20
IEC 60051-5:2017 applies to direct acting indicating phase meters, power factor meters and synchroscopes having an analogue display. This document also applies to non-interchangeable accessories (as defined in 3.1.23 of IEC 60051-1:2016) used with phase meters, power factor meters and synchroscopes. This document also applies to a phase meter or power factor meter whose scale marks do not correspond directly to its electrical input quantity, provided that the relationship between them is known. This fifth edition cancels and replaces the fourth edition published in 1985. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) updating of content in line with new editions of IEC 60051-1 and IEC 60051-9; b) addition of Annex A to specify the nonconformity classification of test items.
Abstract
Overview
IEC 60051-5:2017 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies special requirements for direct acting indicating analogue electrical measuring instruments-specifically, phase meters, power factor meters, and synchroscopes. This standard is part of the IEC 60051 series that deals with analogue electrical measuring instruments and their accessories.
This fifth edition, published in 2017, supersedes the previous 1985 edition, incorporating technical revisions to align with updated editions of related IEC standards IEC 60051-1 and IEC 60051-9. It applies to instruments with analogue displays used for measuring phase angles, power factors, and synchronization signals, including their non-interchangeable accessories.
Key Topics
-
Scope and Application
IEC 60051-5:2017 covers analogue direct acting phase meters, power factor meters, and synchroscopes. It also applies to devices whose scales do not directly correspond to electrical input but maintain known relationships to measured quantities. The standard defines specifications for performance, construction, and safety. -
Performance Requirements
- Limits of intrinsic and operating uncertainty
- Accuracy classes corresponding to uncertainty limits
- Reference conditions and nominal ranges for use
- Electrical safety including self-heating, permissible overloads, and electromagnetic compatibility (EMC)
- Deviation from zero and damping factors
-
Constructional and Design Specifications
- Mechanical construction and degree of protection against environmental factors
- Scale marks, including requirements where scales are not directly proportional to inputs
- Sealing and prevention of unauthorized access
- Adjustment mechanisms (mechanical and electrical)
- Terminals and markings, especially for earthing and measuring circuits
-
Testing and Compliance
- Nonconformity classifications for tests included in Annex A
- Clear definitions of test conditions and tolerances for evaluation
- Packaging and instructions for use to ensure integrity and usability
Applications
IEC 60051-5:2017 plays a crucial role in industries where accurate measurement of phase angle, power factor, and synchronization between electrical systems is critical. Common applications include:
- Power Generation and Distribution
Ensuring correct phase matching and load power factor measurement for energy efficiency and system stability. - Industrial Electrical Equipment
Monitoring and control of electrical motors, converters, and synchronous machines. - Electrical Maintenance and Testing
Calibration and fault diagnosis using standardized instruments adhering to this standard. - Renewable Energy Systems
Synchronization of renewable power sources with grid systems through compliant synchroscopes.
Compliance with IEC 60051-5 ensures that analogue measurement instruments used in these fields meet international performance, safety, and durability criteria, fostering interoperability and reliability.
Related Standards
- IEC 60051-1:2016 – General requirements and definitions for direct acting indicating analogue electrical measuring instruments, which serves as the foundational reference for part 5.
- IEC 60051-9 – Specific requirements relating to other types of analogue electrical measuring instruments.
- IEC 61010 series – Safety requirements for electrical equipment for measurement, control, and laboratory use.
- IEC 61326 – Electromagnetic compatibility (EMC) requirements for electrical measurement equipment.
Together, these standards form a comprehensive framework guiding the design, testing, and application of analogue electrical measurement devices worldwide.
Keywords: IEC 60051-5, analogue electrical measuring instruments, phase meters, power factor meters, synchroscopes, IEC standards, direct acting indicating instruments, electrical measurement, calibration, power system synchronization, instrumentation accuracy, electromagnetic compatibility.
Технические детали
- Технический комитет
- TC 85 - Measuring equipment for electrical and electromagnetic quantities
- SKU
- IEC 60051-5:2017
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60051-1:2016
ДействующийDirect acting indicating analogue electrical measuring instruments and their accessories - Part 1: Definition…
Overview IEC 60051-1:2016 is an international standard published by the International Electrotechnical Commission (IEC) that defines direct acting indicating analogue electrical measuring instruments…
IEC 60051-8:2017
ДействующийDirect acting indicating analogue electrical measuring instruments and their accessories - Part 8: Special re…
Overview IEC 60051-8:2017 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the special requirements for accessories used with direct acting…
IEC 60051-9:2019
ДействующийDirect acting indicating analogue electrical measuring instruments and their accessories - Part 9: Recommende…
Overview IEC 60051-9:2019 is an international standard published by the International Electrotechnical Commission (IEC) that specifies recommended test methods for direct acting indicating analogue e…
IEC TR 61010-3-051:1999
ОтменёнSafety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-051: Confo…
IEC 61326-2-5:2020
ДействующийElectrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular re…
Overview IEC 61326-2-5:2020 is a part of the IEC 61326 series that defines EMC requirements specifically for the field bus interfaces of field devices used in process control and process measuring. T…