IEC 60079-17:2023
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 144
- Дата публикации:
- 1 декабря 2023 г.
- Издание:
- IEC IS 60079 edition 6 version 1
- ICS:
- 29.260.20
IEC 60079-17:2023 applies to users and covers only those factors directly related to the inspection and maintenance of electrical installations specifically designed for hazardous areas, where the hazard is caused by explosive atmospheres. It does not include: - other fundamental installation and inspection requirements for electrical installations; - the verification of electrical equipment; - protection or ventilation of rooms; - gas detection systems; - the repair, overhaul and reclamation of explosion protected equipment (see IEC 60079-19). While this document does not include inspection of safety devices such as used in ventilated rooms (see IEC 60079-13), it does include the requirements for inspection and maintenance of individual items of equipment that will be part of such systems, for example motors or sensors. This document supplements the requirements for inspection and testing in non-hazardous areas in IEC 60364-6. This document is intended to be applied where there is a risk due to the potential presence of explosive gas or dust mixtures with air or combustible dust layers under normal atmospheric conditions. It does not apply to: - underground mining areas, - dusts of explosives, - pyrophoric substances. This sixth edition cancels and replaces the fifth edition published in 2013. This edition constitutes a technical revision.
Abstract
Overview
IEC 60079-17:2023 - Explosive atmospheres - Part 17: Electrical installations inspection and maintenance - is the 6th edition technical revision addressing inspection and maintenance of electrical installations located in hazardous areas where explosive atmospheres (flammable gas, vapour or combustible dust) may occur under normal atmospheric conditions.
The standard applies to users and focuses on factors directly related to inspection and maintenance of electrical installations in hazardous areas. It supplements requirements for non-hazardous areas found in IEC 60364-6 and supersedes the 2013 edition. Not covered are equipment verification, repair/overhaul (see IEC 60079-19), ventilation and room protection, gas detection systems, underground mining, dusts of explosives or pyrophoric substances.
Key topics and requirements
- Documentation and records: Requirements for inspection schedules, test records and supporting documentation for hazardous-area electrical installations.
- Competence and training: Defined knowledge, skills and competencies for responsible persons, technical staff and skilled operatives (see normative annex on qualifications).
- Inspection types and grades: Definitions of periodic inspections, continuous supervision and inspection grades/types to determine scope and frequency.
- Maintenance principles: Safe remedial measures, withdrawal from service, maintenance of flexible cables and requirements for modifications.
- Isolation, earthing and bonding: Guidance on safe isolation, earthing, equipotential bonding and live maintenance considerations (including intrinsically safe circuits).
- Environmental and service conditions: External influences, adverse service conditions and fitness-for-purpose assessment procedures.
- Protection-type specific schedules: Inspection tables and schedules for protection concepts such as Ex d (flameproof), Ex e (increased safety), Ex i (intrinsic safety), Ex p (pressurised), Ex n, Ex t/tD and Ex o (liquid immersion).
- Annexes: Practical aids including typical inspection procedures, competency matrices, fitness-for-purpose assessment, motor checks and adverse service conditions.
Practical applications
- Establishing compliant inspection and maintenance programs for facilities with hazardous areas.
- Developing inspection schedules and checklists tailored to the equipment protection type (Ex d, Ex e, Ex i, etc.).
- Training and qualifying staff responsible for hazardous-area electrical inspections.
- Performing fitness-for-purpose assessments and documenting safety evidence for audits and regulatory compliance.
Who should use this standard
- Maintenance engineers, electrical inspectors and safety managers in oil & gas, chemical, petrochemical, pharmaceutical, grain handling and other industries with explosive atmospheres.
- Facility owners/operators, engineering contractors, inspection bodies and competence assessors responsible for hazardous-area electrical installations.
Related standards
- IEC 60079-1, -2, -7, -11, -13, -19, -31 (protection types and complementary guidance)
- IEC 60364-6 (inspection and testing in non-hazardous areas)
Keywords: IEC 60079-17:2023, explosive atmospheres, electrical installations, inspection and maintenance, hazardous areas, intrinsic safety, inspection schedules, periodic inspections.
Технические детали
- Технический комитет
- SC 31J - Classification of hazardous areas and installation requirements
- SKU
- IEC 60079-17:2023
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60364-6-61:2001
Electrical installations of buildings - Part 6-61: Verification - Initial verification
IEC 60079-19:2025
ДействующийExplosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
Overview IEC 60079-19:2025 - Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation - is the fifth edition (2025) of the international guidance for service facilities that overha…
IEC 60079-10-2:2026
ДействующийExplosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
Overview IEC 60079-10-2:2026, published by the International Electrotechnical Commission (IEC), sets out guidelines for the identification and classification of areas where explosive dust atmospheres…