IEC 60079-28:2025
Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 30
- Дата публикации:
- 21 ноября 2025 г.
- Издание:
- IEC IS 60079 edition 3 version 1
- ICS:
- 29.260.20
IEC 60079-28:2025 specifies additional requirements for Ex Equipment, Ex associated equipment or Ex Components containing optical systems emitting optical radiation, which is exposed to explosive atmospheres. These additional requirements are applicable for all equipment groups and all Equipment Protection Levels (EPL). This document contains requirements for optical radiation in the wavelength range from 380 nm to 10 µm. It covers the following ignition mechanisms: • Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this might allow them to attain a temperature which will ignite a surrounding explosive atmosphere. • In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point. • Annex A provides guidance when considering ignition mechanisms that influence the hazard of optics in explosive atmospheres. This document applies to a) laser equipment; and b) optical fibre equipment; and c) any optical system that converts light into convergent beams with focal points within the hazardous area only. This document does not apply to: d) laser equipment for EPL Mb, Gb, Gc, Db or Dc applications which complies with Class 1 limits in accordance with IEC 60825-1; or e) Single or multiple optical fibre cables not part of optical fibre equipment if the cables: 1) comply with the relevant industrial standards for optical fibre cables, along with additional protective means, for example robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc); or 2) comply with the relevant industrial standards for optical fibre cables (for EPL Gc or Dc); or f) Optical radiation sources as defined in i) to iii) above where the optical radiation is fully contained in an enclosure complying with one of the following Types of Protection suitable for the EPL, or the minimum ingress protection rating specified: 1) flameproof "d" enclosures (IEC 60079-1); or 2) pressurized "p" enclosures (IEC 60079-2); or 3) restricted breathing "nR" enclosure (IEC 60079-15); or 4) dust protection "t" enclosures" (IEC 60079-31); or 5) an enclosure that provides a minimum ingress protection of IP 6X and where no internal absorbers are to be expected and complying with "Tests of enclosures" in IEC 60079-0. This document does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this document. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision
Abstract
Overview - IEC 60079-28:2025 (Explosive atmospheres - Optical radiation)
IEC 60079-28:2025 is the third edition international standard that sets additional requirements for equipment and transmission systems using optical radiation in hazardous (explosive) atmospheres. It covers optical wavelengths from 380 nm to 10 µm and applies to laser equipment, optical fibre equipment, and optical systems that produce convergent beams with focal points inside the hazardous area. The standard supplements and modifies IEC 60079-0 and takes precedence where conflicts occur.
Key technical topics and requirements
- Scope & exclusions
- Addresses ignition mechanisms most relevant in practice: absorption-heating of surfaces/particles and, for strong pulsed beams, laser-induced gas breakdown (plasma/shock).
- Excludes ultraviolet ignition mechanisms and direct absorption ignition of the explosive mixture by the radiation itself.
- Lists exclusions for Class 1 lasers under IEC 60825-1, certain standalone fibre cables, and radiation fully contained in compliant enclosures.
- Types of Protection
- Defines protection concepts for optical radiation such as inherently safe "op is", protected "op pr", and optical system with interlock "op sh".
- Cross-references established enclosure Types of Protection (flameproof "d", pressurized "p", restricted breathing "nR", dust protection "t") and minimum ingress protection (IP6X) where applicable.
- Radiation characteristics
- Separate requirements for continuous-wave and pulsed radiation, including over-power/energy fault protection.
- Provides tables for safe optical power and irradiance by equipment group, EPL and temperature class (detailed in the standard).
- Verification, testing and marking
- Specifies type verifications and tests (optical detectors, optical power, irradiance) and marking requirements for compliance and traceability.
- Guidance annexes
- Annex A explains ignition mechanisms; Annex B outlines typical fibre cable design; Annex C and other informative material support assessment of pulsed radiation.
Practical applications
- Use IEC 60079-28:2025 when designing, certifying or installing:
- Laser systems and optical transmitters in petrochemical plants, mining, or dust-hazard environments
- Optical fibre equipment and transmission links that traverse or terminate inside hazardous zones
- Sensors, measurement, and material-processing optics located within classified areas
- It helps manufacturers and system integrators define safety measures (power limits, interlocks, enclosures) to achieve required Equipment Protection Levels (EPLs).
Who should use this standard
- Product designers and OEMs of lasers and optical equipment
- Certification bodies and test laboratories
- Plant safety engineers, installers and maintenance teams
- Compliance officers and auditors responsible for explosive-atmosphere safety
Related standards
- IEC 60079-0 (general Ex requirements)
- IEC 60079-1, -2, -15, -31 (Types of Protection / enclosures)
- IEC 60079-10-1 / 10-2 (area classification)
- IEC 60825-1 (laser safety limits)
Технические детали
- Технический комитет
- TC 31 - Equipment for explosive atmospheres
- SKU
- IEC 60079-28:2025
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60079-0:2017
ДействующийExplosive atmospheres - Part 0: Equipment - General requirements
Overview IEC 60079-0:2017 - Explosive atmospheres - Part 0: Equipment - General requirements - sets the baseline general requirements for the construction, testing and marking of Ex Equipment and Ex…
SIST EN IEC 60825-12:2026
ДействующийSafety of laser products - Part 12: Safety of free space optical communication systems used for transmission…
Overview SIST EN IEC 60825-12:2026 defines safety requirements for products emitting laser radiation specifically designed for free space optical communication systems (FSOCS). These systems employ l…
IEC 60079-10-2:2026
ДействующийExplosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
Overview IEC 60079-10-2:2026, published by the International Electrotechnical Commission (IEC), sets out guidelines for the identification and classification of areas where explosive dust atmospheres…
IEC 60079-10-1:2020
ДействующийExplosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
Overview IEC 60079-10-1:2020 - Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres - defines the methodology for classifying three‑dimensional areas where flammable…