IEC 60079-31:2022 is applicable to equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of Ex Equipment and Ex Components. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This document does not apply to Ex Equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This document does not take account of any risk due to an emission of flammable or toxic gas from the dust. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. Main significant changes from the previous edition are: 1) Document has been restructured from edition 2 2) Fault current rating of interrupting contacts in clauses 4.3.1 and 4.4.1, major change type C1 3) Cells and batteries in clauses 4.3.5.1 and 4.4.5.1, major change type C2 4) Overload or malfunction condition for the determination of temperature class for "tb" converter fed rotating electric machines, major change type C3 5) Additional requirements for entry devices with dust ignition protection by enclosure "t", major change type C4 Information about the background of ‘Major Technical Changes’ C1 – Ex Equipment having Level of Protection "ta" shall be rated for connection to a circuit with a prospective short circuit current of not greater than 1.5 kA. For Ex Equipment having Level of Protection "tb" or "tc" which is intended for mains connection and intended to interrupt fault current above 10kA, the equipment shall have a rated maximum short circuit withstand current, be tested according to 6.1.1.1, and be marked according to Clause 7. C2 – For Ex Equipment having Level of Protection "ta" which contains a cell or battery, only a sealed cell or battery shall be used. For Ex Equipment having Level of Protection "tb" and "tc" where there are sparking contacts or hot surfaces, and which contains a cell or battery, only a sealed cell or battery shall be used. C3 – Table 2 now includes malfunction conditions for temperature class determination of Level of Protection "tb" converter-fed electric machines. C4 – Annex A added for entry devices with Type of Protection "t" including cable transit devices. The contents of the corrigendum of October 2023 have been included in this copy.
Abstract
Overview
IEC 60079-31:2022 - "Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure 't'" specifies requirements for the design, construction, testing and marking of equipment and components protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It supplements and modifies the general requirements of IEC 60079-0 and takes precedence where the two conflict. This third edition (2022, with corrigendum October 2023 included) is a technical revision of the 2013 edition.
The standard applies to Ex Equipment and Ex Components using dust ignition protection by enclosure (“t”) and excludes:
- dusts of explosives that do not require atmospheric oxygen,
- pyrophoric substances, and
- equipment intended for underground mine workings or mine installations endangered by firedamp and/or combustible dust.
Key topics and requirements
- Levels of protection (ta, tb, tc) - defines protection levels, ingress protection relationship and related construction rules.
- Design & construction - requirements for joints, gaskets, threaded joints, windows, operating shafts, and supplementary internal enclosures to prevent dust ingress.
- Entries & cable transit devices - specific provisions for cable glands, cable transit devices and conduit sealing devices; Annex A adds supplementary requirements for entry devices (including cable transit).
- Electrical components & batteries - rules for cells and batteries (sealed cells required for many protection levels) and protection against overheating.
- Fault current and interrupting contacts - new/updated requirements for fault-current ratings; e.g., Ex equipment with Level "ta" limited to prospective short-circuit ≤ 1.5 kA; equipment intended to interrupt >10 kA must be tested and marked (major change C1).
- Temperature control & classification - determination of maximum surface temperature and updated malfunction/overload conditions for converter-fed rotating machines (major change C3).
- Verification & testing - type tests (including dust exclusion by enclosure), routine tests, and marking rules. Thermal tests for some aspects are referenced to IEC 60079-0.
Applications
IEC 60079-31 is used to ensure that electrical and non-electrical equipment placed in dust-hazardous industrial environments (mills, grain handling, food processing, chemical plants, metal powders, cement, etc.) do not ignite combustible dusts by hot surfaces, arcing or sparking. Typical equipment covered:
- motors, drives and control gear enclosed for dust protection
- lighting and instrumentation enclosures
- cable transit assemblies and entry devices
- battery-powered devices where sealed cells are required
Who should use this standard
- Equipment manufacturers and designers of Ex Equipment and Ex Components
- Test laboratories and certification bodies assessing dust-protected enclosures
- Electrical and safety engineers responsible for hazardous area installations
- Regulatory and compliance teams preparing technical documentation and marking
Related standards
- IEC 60079-0 (general requirements for explosive atmospheres) - this document supplements and modifies it.
- Other IEC 60079 series parts for specific protection concepts and hazardous-area practices.
Keywords: IEC 60079-31, explosive atmospheres, dust ignition protection, enclosure "t", Ex Equipment, dust atmospheres, cable transit, temperature class, fault current, sealed batteries.
Технические детали
- Технический комитет
- TC 31 - Equipment for explosive atmospheres
- SKU
- IEC 60079-31:2022
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60079-0:2017
ДействующийExplosive atmospheres - Part 0: Equipment - General requirements
Overview IEC 60079-0:2017 - Explosive atmospheres - Part 0: Equipment - General requirements - sets the baseline general requirements for the construction, testing and marking of Ex Equipment and Ex…
IEC 60079-31:2013
ДействующийExplosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Overview IEC 60079-31:2013 is an international standard developed by the International Electrotechnical Commission (IEC) that addresses the requirements for electrical equipment used in explosive dus…
IEC 60079-10-2:2026
ДействующийExplosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
Overview IEC 60079-10-2:2026, published by the International Electrotechnical Commission (IEC), sets out guidelines for the identification and classification of areas where explosive dust atmospheres…