IEC 60079-5:2015 contains specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components in the type of protection powder filling "q", intended for use in explosive gas atmospheres. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard applies to electrical equipment, parts of electrical equipment and Ex components with: - a rated supply current less than or equal to 16 A; - a rated supply voltage less than or equal to 1 000 V; - a rated power consumption less than or equal to 1 000 W. This fourth edition cancels and replaces the third edition, published in 2007, and constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 4.0 and previous edition of the document. Keywords: electrical equipment and Ex components in the type of protection powder filling "q"
Abstract
Overview
IEC 60079-5:2015 - "Explosive atmospheres – Part 5: Equipment protection by powder filling 'q'" specifies construction, testing and marking requirements for electrical equipment and Ex components in the type of protection powder filling 'q' intended for use in explosive gas atmospheres. This 4th edition (2015) is a technical revision that supersedes the 2007 edition and supplements the general requirements of IEC 60079-0. Where this standard conflicts with IEC 60079-0, IEC 60079-5 takes precedence. The standard applies to equipment with rated supply current ≤ 16 A, rated voltage ≤ 1000 V and rated power ≤ 1000 W. Type “q” typically provides Equipment Protection Levels EPL Gb or Mb.
Key topics and requirements
The standard covers practical and testable requirements including:
- Constructional requirements
- Definition and design of the container (housing) and sealing/closing arrangements
- Filling procedures and handling of powder filling material
- Material specification and documentation for filling media
- Clearances and distances
- Required distances through filling material and surrounding free space to prevent ignition
- Rules for creepage distances and reduced distances in specific situations
- Temperature limitations
- Maximum temperatures for overload and fault/malfunction conditions and protective measures (fuses, temperature-limiting devices)
- Verifications and tests
- Type tests (pressure test of container, dielectric strength test of filling material, maximum temperature verification)
- Routine and batch tests (routine pressure and dielectric tests)
- Degree of protection (IP) verification for enclosures
- Marking and instructions
- Mandatory marking and user instructions specific to powder-filled Ex equipment
- Annex A
- Alternative risk assessment method relating EPLs to hazardous zones
Practical applications and users
IEC 60079-5 is used by:
- Manufacturers and designers of intrinsically safe modules, transformers, relays, fuses, control gear and other Ex components that can be powder-filled
- Certification bodies and testing laboratories performing type and routine testing
- Safety engineers, procurement and maintenance teams specifying compliant equipment for explosive gas atmospheres (chemical, oil & gas, petrochemical, mining)
- Compliance officers aligning product design with IEC 60079 series requirements
Typical items covered include electronic circuits, transformers, protection fuses, relays, intrinsically safe apparatus, switches and associated electrical apparatus when protected by powder filling.
Related standards
- IEC 60079-0 (general requirements)
- IEC 60079-1 (flameproof "d"), IEC 60079-7 (increased safety "e"), IEC 60079-11 (intrinsic safety "i")
- IEC 60529 (IP codes), IEC 60127 (miniature fuses) and transformer safety standards referenced for specific tests
Keywords: IEC 60079-5, explosive atmospheres, powder filling "q", equipment protection, Ex components, EPL Gb, EPL Mb, electrical equipment.
Технические детали
- Технический комитет
- TC 31 - Equipment for explosive atmospheres
- SKU
- IEC 60079-5:2015
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60079-0:2017
ДействующийExplosive atmospheres - Part 0: Equipment - General requirements
Overview IEC 60079-0:2017 - Explosive atmospheres - Part 0: Equipment - General requirements - sets the baseline general requirements for the construction, testing and marking of Ex Equipment and Ex…
IEC 60079-10-2:2026
ДействующийExplosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
Overview IEC 60079-10-2:2026, published by the International Electrotechnical Commission (IEC), sets out guidelines for the identification and classification of areas where explosive dust atmospheres…
IEC 60079-1-1:2002
Electrical apparatus for explosive gas atmospheres - Part 1-1: Flameproof enclosures "d" - Method of test for…
IEC PAS 61076-3-109:2001
ОтменёнConnectors for electronic equipment - Part 3-109: Detail specification for two-part cable to board connector…
IEC 60127-8:2018
ДействующийMiniature fuses - Part 8: Fuse resistors with particular overcurrent protection
Overview IEC 60127-8:2018 (Edition 1.1, 2018 + AMD1:2024) defines requirements and test methods for miniature fuse-resistors with particular overcurrent protection rated up to AC 500 V and/or DC 500…