IEC 60317-0-8:2012
Specifications for particular types of winding wires - Part 0-8: General requirements - Polyester glass fibre wound, resin or varnish impregnated or not impregnated, bare or enamelled rectangular copper wire
Specifications for particular types of winding wires - Part 0-8: General requirements - Polyester glass fibre wound, resin or varnish impregnated or not impregnated, bare or enamelled rectangular copper wire
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 48
- Дата публикации:
- 12 июля 2012 г.
- Издание:
- IEC IS 60317 edition 1 version 1
- ICS:
- 29.060.10
IEC 60317-0-8:2012 specifies general requirements of polyester glass fibre wound, resin or varnish impregnated or not impregnated, bare or enamelled rectangular copper wire. Keywords: copper wire
Abstract
Overview
IEC 60317-0-8:2012 sets forth the general requirements for specific types of winding wires used in electrical and electronic applications. This International Electrotechnical Commission (IEC) standard focuses particularly on polyester glass fibre wound, resin or varnish impregnated (or not), bare or enamelled rectangular copper wire. Winding wires conforming to this standard ensure performance and reliability in electrical equipment by meeting strict specifications related to their construction, dimensions, and electrical properties.
This standard forms part of the broader IEC 60317 series, which details specifications for various winding wires. It is essential for manufacturers, designers, and testing labs involved in electrical machinery and transformer production, ensuring product quality and international consistency.
Key Topics
- Material Composition: Polyester glass fibre winding, with or without resin or varnish impregnation, applied on bare or enamelled rectangular copper wire conductors.
- Dimensional Specifications:
- Conductor sizes and tolerances to maintain precise dimensions critical for winding efficiency.
- Corner radii and dimensional changes due to insulation coatings.
- Electrical Properties:
- Resistance values ensuring optimal conductivity.
- Testing for continuity of insulation and breakdown voltage to guarantee performance under electrical stress.
- Mechanical Characteristics:
- Elongation and flexibility assessments such as the mandrel winding test.
- Adherence quality of coverings and resistance to abrasion, solvents, solderability, and heat shock.
- Testing Methods: References IEC 60851 for test methods, incorporating rigorous procedures for evaluating coating integrity, dielectric properties, and soldering compatibility.
Applications
Winding wires that comply with IEC 60317-0-8:2012 are predominantly used in:
- Electric Motors and Generators: Offering reliable insulation and conductor properties required for electromagnetic windings.
- Transformers: Ensuring effective energy transfer through quality wire insulation and dimensional precision.
- Electromechanical Devices: Including relays, solenoids, and inductors, which demand high-quality copper wire with robust insulation.
- Industrial and Consumer Electronics: Providing standardized winding wire solutions that enhance device longevity and safety.
- Automotive Electrical Components: Supporting high temperature and mechanical stress resilience in vehicle motors and electronics.
By adhering to this standard, manufacturers ensure enhanced durability, heat resistance, and operational reliability of winding wires used in demanding environments.
Related Standards
- IEC 60317 Series: Covers additional specialized winding wire specifications beyond polyester glass fibre wound types.
- IEC 60851 (All Parts): Details the test methods for winding wires, crucial for verifying compliance with IEC 60317-0-8.
- IEC 60264: Addresses packaging requirements for winding wires to maintain quality during transportation and storage.
- ISO 3:1973: Defines preferred numbers used for nominal dimensions in this standard.
Understanding and integrating these standards ensures comprehensive quality management across the manufacturing and application processes of winding wires.
Keywords: IEC 60317-0-8, winding wires, polyester glass fibre, rectangular copper wire, enamelled copper wire, resin impregnated wire, varnish impregnated wire, electrical insulation, conductor dimensions, electrical resistance, winding wire standards.
Технические детали
- Технический комитет
- TC 55 - Winding wires
- SKU
- IEC 60317-0-8:2012
Похожие стандарты
Стандарты, упомянутые в описании
ISO 3:1973
ДействующийPreferred numbers — Series of preferred numbers
Overview ISO 3:1973, titled Preferred numbers - Series of preferred numbers, is an international standard established by the International Organization for Standardization (ISO). Published in 1973, t…
IEC 60317-17:2010
ДействующийSpecifications for particular types of winding wires - Part 17: Polyvinyl acetal enamelled rectangular copper…
Overview IEC 60317-17:2010 is an international standard issued by the International Electrotechnical Commission (IEC) detailing the specifications for polyvinyl acetal enamelled rectangular copper wi…
IEC 60851-1:1996
ДействующийMethods of test for winding wires - Part 1: General
Overview IEC 60851-1:1996 titled Methods of test for winding wires - Part 1: General is an international standard published by the International Electrotechnical Commission (IEC). This second edition…
IEC 60264-3-5:1999
ДействующийPackaging of winding wires - Part 3-5: Taper barrelled delivery spools - Specification for spool containers m…
Overview IEC 60264-3-5:1999 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the requirements for spool containers made from thermoplastic…