IEC 60601-2-21:2020
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 118
- Дата публикации:
- 3 ноября 2023 г.
- Издание:
- IEC IS 60601 edition 3 version 1
- ICS:
- 11.040.10
IEC 60601-2-21:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard. IEC 60601-2-21:2020 specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: - devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35; - INFANT INCUBATORS; for information, see IEC 60601-2-19; - INFANT TRANSPORT INCUBATORS, for information, see IEC 60601-2-20; - INFANT PHOTOTHERAPY EQUIPMENT, for information, see IEC 60601-2-50. SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED RADIANT WARMER including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56. IEC 60601-2-21:2020 cancels and replaces the second edition published in 2009 and Amendment 1:2016. This edition constitutes a technical revision. IEC 60601-2-21:2020 includes the following significant technical change with respect to the previous edition: alignment with IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012.
Abstract
Overview
IEC 60601-2-21:2020 is an internationally recognized standard that specifies the particular requirements for the basic safety and essential performance of infant radiant warmers - electrically powered devices designed to maintain the thermal balance of infants by direct infrared radiation. Developed by the International Electrotechnical Commission (IEC), this standard supplements the general requirements of IEC 60601-1 with tailored provisions to address the unique risks and performance criteria associated with equipment used for infant thermal care in clinical and neonatal environments.
The standard applies specifically to infant radiant warmers, covering devices as defined in IEC 60601-2-21, but does not apply to equipment such as heated mattresses, incubators, infant transport incubators, or infant phototherapy devices, each of which is regulated by separate IEC standards.
Key Topics
IEC 60601-2-21:2020 focuses on:
- Basic Safety: Ensuring electrical, mechanical, and thermal hazards are minimized for both patients and operators.
- Essential Performance: Clarifying the necessary device functions to maintain consistent, effective heating for infants.
- Modes of Operation:
- Manual mode: Operator sets a fixed heating level.
- Baby controlled mode: Heater output automatically adjusts to keep skin temperature at the preset level.
- Prewarm mode: For pre-heating the device before patient use.
- Control and Monitoring: Requirements for accurate temperature control displays, alarm systems, and sensor use.
- Operator Instructions: Clear labeling and usage guidelines, including warnings about temperature sensor placement, acceptable distances from heating sources, and limitations of the device.
- Risk Management: Mandates a risk management approach to demonstrate the acceptability of any alternative compliance methods when meeting safety objectives.
- Compatibility & Integration: Specifies requirements where radiant warmers are used with other medical electrical equipment, and outlines necessary supporting documentation.
Applications
Infant radiant warmers are critical in various medical care settings, such as:
- Neonatal intensive care units (NICUs): Supporting thermoregulation for premature or critically ill infants immediately after birth or surgery.
- Labor and delivery rooms: Preventing hypothermia during neonatal resuscitation and early postnatal care.
- Pediatric wards: Providing a controlled thermal environment for infants requiring observation or intervention.
Meeting the requirements of IEC 60601-2-21:2020 is essential for:
- Medical device manufacturers: To demonstrate regulatory compliance, support CE marking or FDA clearance, and ensure product marketability.
- Healthcare providers: To select and operate equipment that meets international standards for safety and performance.
- Testing laboratories and certification bodies: As a benchmark for conformity assessments.
Related Standards
IEC 60601-2-21:2020 is part of a broader family of IEC standards for medical electrical equipment. Key related standards include:
- IEC 60601-1: General requirements for basic safety and essential performance.
- IEC 60601-2-19: Particular requirements for infant incubators.
- IEC 60601-2-20: Infant transport incubators.
- IEC 60601-2-35: Heating devices using blankets, pads, or mattresses.
- IEC 60601-2-50: Infant phototherapy equipment.
- IEC 60601-1-2: Electromagnetic compatibility.
- ISO 80601-2-56: Clinical thermometers.
- IEC 80601-2-49: Requirements for patient monitoring equipment, when physiologic monitoring is integrated.
Manufacturers and users should reference the appropriate standard based on the specific device application to ensure comprehensive safety and performance compliance.
IEC 60601-2-21:2020 ensures that infant radiant warmers meet rigorous safety and performance levels, contributing to improved outcomes and assurance in neonatal thermal care worldwide. For the latest updates, always consult the most recent edition directly from the IEC or an authorized distributor.
Технические детали
- Технический комитет
- SC 62D - Particular medical equipment, software, and systems
- SKU
- IEC 60601-2-21:2020
Похожие стандарты
Стандарты, упомянутые в описании
IEC TR 62348:2012
ДействующийAssessment of the impact of the most significant changes in Amendment 1 to IEC 60601-1:2005 and mapping of th…
Overview IEC TR 62348:2012 is a Technical Report from the International Electrotechnical Commission that helps users transition from IEC 60601-1:2005 (Edition 3) to the amended edition (Amendment 1:2…
IEC 60601-2-19:2020
ДействующийMedical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performa…
Overview IEC 60601-2-19:2020 is the third edition (2020) particular standard in the IEC 60601 series that specifies the basic safety and essential performance requirements for infant incubators - a c…
IEC 60601-2-20:2020
ДействующийMedical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performa…
Overview IEC 60601-2-20:2020 is the particular standard in the IEC 60601 series that specifies requirements for the basic safety and essential performance of infant transport incubators (medical elec…
IEC 60601-2-35:2020
ДействующийMedical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performa…
Overview IEC 60601-2-35:2020 is the particular part of the IEC 60601 series that defines the basic safety and essential performance requirements for medical electrical heating devices using blankets,…
IEC 60601-2-50:2020
ДействующийMedical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performa…
Overview IEC 60601-2-50:2020 is the third edition particular standard in the IEC 60601 series that defines the basic safety and essential performance requirements for infant phototherapy equipment (m…
IEC 60601-1-2:2014
ДействующийMedical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Co…
Overview IEC 60601-1-2:2014, published by the International Electrotechnical Commission (IEC), defines the requirements and tests relating to the basic safety and essential performance of medical ele…
ISO 80601-2-56:2017
ДействующийMedical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance…
Overview ISO 80601-2-56:2017 - Medical electrical equipment: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement - defines saf…