IEC 60684-3-247:2011
Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 247: Heat-shrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall
Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 247: Heat-shrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 24
- Дата публикации:
- 14 декабря 2016 г.
- Издание:
- IEC IS 60684 edition 1 version 1
- ICS:
- 29.035.20
IEC 60684-3-247:2011 gives the requirements for two types of heat-shrinkable, polyolefin sleeving, dual wall, not flame retarded with a nominal shrink ratio of 3:1. This sleeving has been found suitable for use at temperatures of up to 100 °C. - Type A: Medium wall, internal diameter up to 200,0 mm typically; and Type B: Thick wall, internal diameter up to 200,0 mm typically.
Abstract
Overview
IEC 60684-3-247:2011 is an international standard developed by the International Electrotechnical Commission (IEC) that outlines specifications for flexible insulating sleeving, particularly heat-shrinkable, polyolefin sleeving with a dual wall, not flame retarded, and available in both thick and medium wall options. This standard is relevant for manufacturers, suppliers, and users seeking high-quality non-flame-retardant insulating solutions for electrical applications requiring thermal and mechanical protection.
The sleeving types covered under this standard offer a nominal shrink ratio of 3:1, making them suitable for various cable sizes and configurations. Typical applications are designed to operate at temperatures of up to 100 °C, supporting both medium wall (Type A) and thick wall (Type B) sleeving options, each with internal diameters up to 200 mm.
Key Topics
- Types of Sleeving:
- Type A (Medium Wall): For applications demanding moderate mechanical protection, with an emphasis on flexibility.
- Type B (Thick Wall): Provides greater impact and abrasion resistance, ideal for more rigorous environments.
- Material Characteristics:
- Constructed from polyolefin materials in a dual wall format, combining strength with insulating qualities.
- Not flame retarded, focusing on electrical insulation and environmental protection.
- Typically supplied in black, but customizable based on user-supplier agreement.
- Shrink Ratio:
- All products feature a 3:1 shrink ratio, enabling effective coverage over varying cable diameters.
- Performance Standards:
- Suitable for continuous operation at temperatures up to 100 °C.
- Performance requirements include dimensions, tensile strength, elongation at break, breakdown voltage, chemical resistance, and environmental durability.
- Test Methods:
- Performance verified through standardized testing procedures as detailed in IEC 60684-2, including tests for physical, electrical, and chemical properties.
Applications
The heat-shrinkable dual wall polyolefin sleeving specified in IEC 60684-3-247:2011 is widely used in various electrical and electronics industries for:
- Cable and Wire Insulation:
- Providing electrical insulation and mechanical protection for cable joints, terminations, and repairs.
- Protective Covering:
- Guarding against moisture ingress, pollutants, and mechanical damage in harsh industrial environments.
- Bundling and Strain Relief:
- Organizing and securing groups of wires or cables within control panels, automotive assemblies, or transport vehicles.
- Medium and Heavy-Duty Applications:
- Type B (thick wall) sleeves are particularly valued in energy, transport, and utility sectors where robust protection is necessary.
- Custom Installations:
- Thanks to the wide range of available sizes (internal diameters up to 200 mm), this sleeving is applicable to both standard and unique installations requiring tailored solutions.
Related Standards
For comprehensive use and reference, the following related IEC standards are significant:
- IEC 60684-1: Flexible insulating sleeving – Definitions and general requirements
- IEC 60684-2: Flexible insulating sleeving – Methods of test
- IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV up to 30 kV
- IEC 60296: Fluids for electrotechnical applications – Unused mineral insulating oils for transformers and switchgear
- IEC 60757: Code for designation of colours
- ISO 846: Plastics – Evaluation of the action of micro-organisms
- ISO 868: Plastics and ebonite – Determination of indentation hardness by means of a durometer (Shore hardness)
Practical Value
Adopting IEC 60684-3-247:2011 ensures that users benefit from an internationally recognized baseline of performance and safety for non-flame-retarded, heat-shrinkable polyolefin sleeving. This standard supports reliable electrical insulation, mechanical protection, and longevity in demanding operational settings, making it a essential reference for electrical engineers, designers, and quality assurance professionals specifying cable sleeving solutions.
Технические детали
- Технический комитет
- TC 15 - Solid electrical insulating materials
- SKU
- IEC 60684-3-247:2011
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60684-2:2011
ДействующийFlexible insulating sleeving - Part 2: Methods of test
Overview IEC 60684-2:2011 is an International Electrotechnical Commission (IEC) standard specifying the methods of test for flexible insulating sleeving, including heat-shrinkable types. Primarily de…
IEC 60684-1:2003
ДействующийFlexible insulating sleeving - Part 1: Definitions and general requirements
Overview IEC 60684-1:2003 is an International Standard published by the International Electrotechnical Commission (IEC) that defines the terms, classification, and general requirements for flexible i…
IEC 60502-1:2021
ДействующийPower cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to…
Overview IEC 60502-1:2021 specifies the construction, dimensions and test requirements for power cables with extruded solid insulation for rated AC voltages of 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 k…
IEC 60296:2012
ДействующийFluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
Overview IEC 60296:2012 - Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear - is the 4th edition (redline version) of the International Electro…
IEC 60757:2021
ДействующийCode for designation of colours
Overview IEC 60757:2021 is an international standard developed by the International Electrotechnical Commission (IEC) that establishes a code for the designation of colours in electrical installation…
ISO 846:2019
ДействующийPlastics — Evaluation of the action of microorganisms
Overview - ISO 846:2019 (Plastics - Evaluation of the action of microorganisms) ISO 846:2019 defines laboratory methods to evaluate how microorganisms (fungi, bacteria and soil microflora) affect pla…
ISO 8681:1986
ДействующийPetroleum products and lubricants — Method of classification — Definition of classes
Overview - ISO 8681:1986 (Petroleum products and lubricants classification) ISO 8681:1986 establishes a general classification system for petroleum products, lubricants and related products and defin…