IEC 61009-2-2:2024
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 2-2: RCBOs according to classification 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 2-2: RCBOs according to classification 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 40
- Дата публикации:
- 21 ноября 2024 г.
- Издание:
- IEC IS 61009 edition 2 version 1
- ICS:
- 29.120.50
IEC 61009-2-2:2024 applies to residual current operated circuit-breakers, with integral overcurrent protection, for household and similar uses (hereafter referred to as RCBOs), classified according to IEC 61009-1:2024, 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6. RCBOs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A and rated short‑circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. This second edition cancels and replaces the first edition published in 1991. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) harmonization of all clauses between the IEC 61008, IEC 61009 and IEC 60755 series using blocks and modules approach; b) harmonization of all tables and figures between the IEC 61008, IEC 61009 and IEC 60755 series; c) terms and definitions are now referred to IEC 62873-2; d) modification of 4.1 for classification according to supply conditions; e) modification of Clause 6 for markings of RCBOs with a functional earth (FE); f) specific tests for operating characteristics of RCBO according to classifications 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6; g) specific test conditions for dielectric properties (9.7), temperature-rise (9.8), electrical and mechanical endurance (9.10), short-circuit tests (9.11), verification of trip-free (9.15), behaviour in the event of loss of the supply voltage (9.17), surge current tests (9.19), reliability (9.20), ageing (9.21) and temporary overvoltage TOV (9.24); h) additional tests for RCBOs with a terminal connected to the FE: Connecting capacity of FE terminal (9.200); Limitation of standing current in the FE (9.201).
Abstract
Overview
IEC 61009-2-2:2024 is the second edition of the International Electrotechnical Commission standard for residual current operated circuit‑breakers with integral overcurrent protection (RCBOs) intended for household and similar uses. This part specifically covers RCBOs classified according to IEC 61009‑1:2024 clauses 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6. It applies to devices for AC supplies up to 440 V, at 50 Hz, 60 Hz or 50/60 Hz, with rated currents up to 125 A and rated short‑circuit capacities up to 25 000 A (50/60 Hz). Edition 2.0 (2024) cancels the 1991 edition and introduces a technical revision with harmonized clause, table and figure structures across related standards.
Key Topics and Requirements
- Scope and classification: Defines RCBOs by supply conditions per IEC 61009‑1 classifications (4.1.2–4.1.6).
- Rated characteristics: Rated voltages, currents and short‑circuit capacities; standard and preferred values.
- Marking and product information: New marking provisions for RCBOs with a functional earth (FE) and other classification‑specific markings.
- Construction and operation requirements: Includes behaviour in the event of loss of supply and resistance to temporary overvoltages (TOV).
- Comprehensive testing regime: Specific tests and conditions for dielectric properties, temperature‑rise, electrical and mechanical endurance, short‑circuit performance, trip‑free verification, surge current behaviour, reliability, ageing, and TOV.
- FE terminal tests: New tests for FE‑connected RCBOs - connecting capacity of FE terminal (9.200) and limitation of standing current in the FE (9.201).
- Reference terms: Terms and definitions are now referenced to IEC 62873‑2 to ensure consistency.
Applications and Practical Value
- Design and manufacture of RCBOs for residential and light‑commercial distribution panels.
- Type testing and product development to meet safety and performance requirements for overcurrent and residual‑current protection.
- Certification and conformity assessment by test laboratories and certification bodies.
- Specification and procurement guidance for electrical engineers, installers and authorities seeking RCBOs that meet harmonized international requirements (voltage, current, short‑circuit capacity, FE behaviour).
- Risk mitigation in electrical installations by ensuring correct operation under TOV, short‑circuit and ageing conditions.
Who Should Use This Standard
- RCBO manufacturers and product designers
- Test laboratories and certification bodies
- Electrical safety engineers and specifiers
- Regulators, utilities and installation contractors
Related Standards
- IEC 61009‑1:2024 (general requirements for RCBOs) - this part is to be used in conjunction with it
- IEC 61008 and IEC 60755 series (harmonized clause/module approach)
- IEC 62873‑2 (terms and definitions)
Keywords: IEC 61009‑2‑2, RCBO, residual current operated circuit‑breaker, overcurrent protection, household, functional earth, TOV, short‑circuit, dielectric test, temperature‑rise, IEC 61009‑1.
Технические детали
- Технический комитет
- SC 23E - Circuit-breakers and similar equipment for household use
- SKU
- IEC 61009-2-2:2024
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61009-1:2024
ДействующийResidual current operated circuit-breakers with integral overcurrent protection for household and similar use…
Overview IEC 61009-1:2024 - Residual current operated circuit‑breakers with integral overcurrent protection (RCBOs) - Part 1: General rules, is the 4th edition international standard that defines gen…
IEC 62873-2:2016
ДействующийResidual current operated circuit-breakers for household and similar use - Part 2: Residual current devices (…
Overview IEC 62873-2:2016 is the vocabulary part of the IEC series for residual current operated circuit‑breakers (RCDs) intended for household and similar use. Its scope is to provide the standardiz…
IEC 61008-2-2:2024
ДействующийResidual current operated circuit-breakers without integral overcurrent protection for household and similar…
Overview IEC 61008-2-2:2024 specifies the requirements for residual current operated circuit-breakers (RCCBs) without integral overcurrent protection, intended for household and similar uses. These R…
IEC 60755:2017
ДействующийGeneral safety requirements for residual current operated protective devices
Overview IEC 60755:2017 - General safety requirements for residual current operated protective devices (RCDs) - is an IEC Group Safety Publication that provides general minimum requirements, recommen…