IEC 61010-2-081:2015
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 41
- Дата публикации:
- 23 января 2015 г.
- Издание:
- IEC IS 61010 edition 2 version 1
- ICS:
- 19.080
IEC 61010-2-081:2015 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a system is within the scope of this standard. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision and includes the following significant changes from the first edition, as well as numerous other changes: - excluded IEC 61010-2-101 (IVD Equipment) from scope. This separates IEC 61010-2-081 and IEC 61010-2-101 equipment; - added biological risks symbol to Table 1 in Clause 5; - added requirement for statement on hazardous substances and gases in Instructions for Use to Clause 5; - Added marking requirement for flow direction to Clause 5; - added requirement for OPERATOR maintenance instructions to Clause 7; - excluded equipment whose size and weight make unintentional movement unlikely from drop test in Clause 8; - added requirement for biohazard marking to Clause 13; - added requirement for interlock systems containing electric/electronic or programmable components to Clause 15. It has the status of a group safety publication in accordance with IEC Guide 104. This publication is to be read in conjunction with IEC 61010-1:2010.
Abstract
Overview
IEC 61010-2-081:2015 is an international safety standard developed by the International Electrotechnical Commission (IEC). It details particular safety requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes. This standard forms part of the broader IEC 61010 series, which addresses general safety standards for electrical equipment used in measurement, control, and laboratory settings.
The standard applies to electrical laboratory instruments and systems that measure or modify sample parameters, with processes performed entirely or partially automatically, minimizing manual intervention. Instruments like analytical equipment, automatic samplers (pipettors, aliquoters), and sample replication or amplification systems fall within its scope.
Key Topics
IEC 61010-2-081:2015 covers essential safety principles specific to laboratory automation equipment, including:
- Separation from In Vitro Diagnostic (IVD) Equipment: IEC 61010-2-101 equipment is excluded from this standard, clarifying scope and ensuring appropriate application.
- Safety Labeling and Markings: New requirements for biological risk symbols, flow direction indicators, and warnings about hazardous substances and gases.
- Instructions for Use: Enhanced expectations for documentation, including clear statements on hazardous substances, gases, and operator maintenance procedures.
- Biohazard Safety: Requirements for biohazard marking on equipment that handles or could produce hazardous biological substances.
- Mechanical Safety: Updates regarding drop testing for heavy or stationary equipment and clear instructions to safeguard operators during maintenance.
- Interlock Systems: New requirements for the reliability and design of electrical/electronic or programmable interlock components.
- Maintenance and Decommissioning: Guidance on the safe removal, repair, and disposal of laboratory equipment, promoting hazard reduction throughout the equipment lifecycle.
Applications
IEC 61010-2-081:2015 is vital for manufacturers, laboratories, and compliance professionals concerned with automatic and semi-automatic analytical laboratory equipment. Practical applications include:
- Product Development: Engineers and designers must align new instrument design with the safety requirements outlined, especially for automated analytical and sample handling systems.
- Procurement and Installation: Laboratory managers use the standard to guide safe selection and commissioning of automated equipment, ensuring it meets internationally recognized benchmarks.
- Compliance Assessment: Safety assessors, notified bodies, and certification organizations reference IEC 61010-2-081 for conformity evaluations, risk assessment, and CE or global market approvals.
- Operational Safety: Laboratory personnel rely on clearly documented procedures and hazard markings to reduce exposure risks related to biohazards, chemicals, or physical harm.
- Sustainability Practices: The requirements for safe decommissioning and disposal help laboratories manage end-of-life equipment responsibly with an emphasis on environmental and personnel safety.
Related Standards
IEC 61010-2-081:2015 is part of a family of standards supporting laboratory safety and equipment conformity:
- IEC 61010-1:2010 - General safety requirements for electrical equipment for measurement, control, and laboratory use. IEC 61010-2-081 should be read in conjunction with this base standard.
- IEC 61010-2-101 - Applies specifically to In Vitro Diagnostic (IVD) medical laboratory equipment.
- IEC Guide 104 - Guidance for group safety publications in the IEC context.
- IEC 62061 and ISO 13849 - Referenced for interlock system functional safety.
- World Health Organization (WHO) Laboratory Biosafety Manual - Recommended for guidance on hazardous substances and biohazard management.
Aligning with IEC 61010-2-081:2015 ensures laboratory equipment manufacturers and users meet global requirements for safety, risk management, and operational excellence in laboratory environments.
Технические детали
- Технический комитет
- TC 66 - Safety of measuring, control and laboratory equipment
- SKU
- IEC 61010-2-081:2015
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61010-1:2010
ДействующийSafety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General r…
Overview IEC 61010-1:2010 is an international standard published by the International Electrotechnical Commission (IEC) that sets general safety requirements for electrical equipment used in measurem…
IEC TR 61010-3-051:1999
ОтменёнSafety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-051: Confo…
IEC TR 61010-3-101:2003
ОтменёнSafety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-101: Confo…
IEC 61010-2-081:2019
ДействующийSafety requirements for electrical equipment for measurement, control and laboratory use - Part 2-081: Partic…
Overview IEC 61010-2-081:2019 - Edition 3.0 - is the International Electrotechnical Commission (IEC) group safety publication that specifies safety requirements for automatic and semi-automatic labor…