IEC 61156-3-2:2001
Multicore and symmetrical pair/quad cables for digital communications - Part 3-2: Work area wiring - Capability Approval - Sectional specification
Multicore and symmetrical pair/quad cables for digital communications - Part 3-2: Work area wiring - Capability Approval - Sectional specification
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 15
- Дата публикации:
- 27 февраля 2001 г.
- Издание:
- IEC IS 61156 edition 1 version 1
- ICS:
- 33.120.20
A sectional specification applies to Capability Approval requirements for cables for digital communications in work area wiring according to IEC 61156-1 and IEC 61156-3.
Abstract
Overview
IEC 61156-3-2:2001 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies Capability Approval requirements for multicore and symmetrical pair/quad cables used in digital communications, specifically for work area wiring. This sectional specification complements IEC 61156-1 (generic specification) and IEC 61156-3 (work area wiring specification), addressing the manufacturing and quality assurance aspects critical to ensuring reliable digital communication infrastructures.
The standard provides guidelines for manufacturers and customers relating to the capability to produce cables that meet consistent performance and quality criteria, supporting transparent evaluation and certification processes. It acts as a practical framework for quality negotiation between cable manufacturers and end-users or third-party certifiers.
Key Topics
-
Scope and Application
IEC 61156-3-2 applies to Capability Approval of cables used for digital communication work area wiring. It defines the requirements for the Capability Manual, quality plans, and the maintenance of approval status. -
Capability Manual Content
The manual must detail the families of cables under the scope including specific construction details such as:- Conductor types and materials
- Insulation and screening materials
- Dimensions and form factors
- Maximum lengths and cable sizes
The manual also covers manufacturing procedures, repair policies, and permissible limits within the production process.
-
Manufacturing Process and Limits
The standard emphasizes clear identification of all manufacturing phases through diagrams or flowcharts. It requires documentation of the machines, working instructions, construction techniques, and control points to ensure traceability and reproducibility. -
Quality Plans and Control
Requirements for quality assurance include:- Defining manufacturing steps and their critical characteristics
- Specifying test procedures and acceptance limits
- Sampling strategies and frequency to monitor ongoing quality
Statistical analysis and trending of quality results are recommended to ensure continuous process improvement.
-
Maintenance of Capability Approval
The standard specifies procedures to maintain ongoing compliance through regular reviews and updates in relation to technological advances or process modifications. This ensures the approved capability remains current and reliable.
Applications
IEC 61156-3-2:2001 is essential for manufacturers producing cables for digital communication networks where work area wiring is critical. Typical applications include:
- Structured cabling systems in commercial and enterprise environments
- Data centers requiring high-performance cable installations
- Telecommunications infrastructure supporting digital signals
- Installation of LAN and WAN wiring where certified quality and performance are mandated
Adopting this standard helps manufacturers demonstrate capability and compliance, facilitates customer confidence, and supports interoperability in global digital communication networks.
Related Standards
This standard works in conjunction with other IEC 61156 parts and related documents to provide a complete framework for cable manufacture and performance evaluation:
- IEC 61156-1: Generic specification for multicore and symmetrical pair/quad cables for digital communications
- IEC 61156-1-1: Capability Approval – Generic specification
- IEC 61156-3: Work area wiring sectional specification, defining performance and construction specifics
- ISO standards: Often referenced for complementary quality management and product certification procedures
Manufacturers and stakeholders should consider the entire IEC 61156 series to ensure full compliance with both capability and performance metrics for digital communication cabling.
Keywords: IEC 61156-3-2, Capability Approval, multicore cables, symmetrical pair/quad cables, work area wiring, digital communications, cable manufacturing, quality plans, international standard, IEC, cable construction, digital communication networks, structured cabling, cable certification.
Технические детали
- Технический комитет
- SC 46C - Wires and symmetric cables
- SKU
- IEC 61156-3-2:2001
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61156-11:2019
ДействующийMulticore and symmetrical pair/quad cables for digital communications - Part 11: Symmetrical single pair cabl…
Overview IEC 61156-11:2019 is the IEC sectional specification for symmetrical single‑pair cables intended for horizontal floor wiring with transmission characteristics up to 600 MHz. It defines cable…
IEC 61156-3:2008
ДействующийMulticore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional s…
Overview IEC 61156-3:2008 is the sectional specification for work area cables within the IEC 61156 series for multicore and symmetrical pair/quad cables for digital communications. It specifies const…
IEC 61156-4:2009
ДействующийMulticore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional spec…
Overview IEC 61156-4:2009 - Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification - is a sectional standard that defines requirements…