IEC 61169-67:2022
Radio frequency connectors - Part 67: Sectional specification for series TRL threaded triaxial connectors
Radio frequency connectors - Part 67: Sectional specification for series TRL threaded triaxial connectors
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 40
- Дата публикации:
- 18 февраля 2022 г.
- Издание:
- IEC IS 61169 edition 1 version 1
- ICS:
- 33.120.30
IEC 61169-67:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRL threaded triaxial connectors. Series TRL threaded triaxial connectors with high reliability, small size, good salt characteristics can be connected with symmetrically twisted pair cables or triaxial cables. It has been used in 1553B data bus systems or other communication systems for digital signal transmission. It specifies mating face dimensions for series TRL threaded triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRL threaded triaxial connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
Abstract
Overview
IEC 61169-67:2022 is an international standard developed by the International Electrotechnical Commission (IEC) that establishes a sectional specification for series TRL threaded triaxial connectors used in radio frequency (RF) applications. This standard provides a comprehensive framework for the preparation of detail specifications for these connectors, which are known for their high reliability, compact size, and excellent resistance to salt corrosion. Designed primarily for use with symmetrically twisted pair cables or triaxial cables, series TRL threaded triaxial connectors are widely implemented in 1553B data bus systems and other digital communication systems for transmitting digital signals.
The document specifically defines key mechanical and electrical parameters such as mating face dimensions, gauging guidelines, and performance test schedules. By adhering to IEC 61169-67:2022, manufacturers and engineers ensure consistent quality and compatibility in RF connector applications, supporting both assessment levels M and H in quality control.
Key Topics
-
Mating Face Dimensions
The standard meticulously specifies the dimensional requirements for the plug and receptacle connectors of the series TRL. Accurate mating face dimensions are critical to ensuring proper connector engagement, mechanical stability, and signal integrity during operation. -
Coaxial Contact Specifications
The document details requirements for coaxial pin and socket contacts, ensuring the connectors provide reliable electrical contact within the triaxial structure. This includes dimensional criteria essential for coaxial pin and socket compatibility. -
Gauges for Resilient Contacts
Specifications include precise gauge dimensions designed to evaluate socket center and intermediate contacts, enabling quality assessment of the physical interface and the resilient contact mechanism. -
Quality Assessment Procedure
IEC 61169-67 outlines comprehensive test schedules and inspection requirements, derived from IEC 61169-1 standards, to assess the connectors' performance. These include acceptance and periodic tests focusing on mechanical, electrical, and environmental durability. -
Preparation of Detail Specifications (DS)
The standard guides the preparation of detailed product specifications by providing a blank pro-forma template and recommendations on performance characteristics, marking, ordering information, and test severity selection.
Applications
-
1553B Data Bus Systems
IEC 61169-67:2022 connectors are integral to MIL-STD-1553B data bus systems, widely used in aerospace and military communication for reliable digital signal transmission with strict environmental and mechanical demands. -
Digital Communication Systems
The standard supports use in other high-reliability digital communication systems requiring secure data transfer via twisted pair or triaxial cables. These connectors ensure minimal signal degradation in complex electronic environments. -
Harsh Environment Deployments
Thanks to their good salt resistance and robust threaded design, series TRL connectors are suitable for deployments in harsh environments where corrosion and mechanical stress are concerns. -
Compact Electronic Assemblies
The small form factor of these connectors promotes their use in compact and densely packed electronic devices and systems, preserving signal integrity without compromising space.
Related Standards
-
IEC 61169-1:2013 – Generic specification addressing general requirements and measuring methods for RF connectors, providing foundational testing and compliance procedures referenced in IEC 61169-67.
-
IEC 61169-1-5 – Electrical test methods covering rise time degradation, critical for assessing signal fidelity in RF connector applications.
-
MIL-STD-1553B – A military standard for digital data bus communication systems, where series TRL threaded triaxial connectors find significant application.
-
ISO/IEC Directives – Guidelines governing the preparation and development of international standards, ensuring IEC 61169-67 follows globally accepted procedures.
By adhering to the IEC 61169-67:2022 standard, engineers, manufacturers, and quality assurance professionals can ensure the design, production, and performance assessment of series TRL threaded triaxial connectors meet international benchmarks. These connectors’ precision mating dimensions and rigorous test protocols help maintain signal integrity and mechanical reliability critical for advanced digital communication systems in defense, aerospace, and industrial environments.
Технические детали
- Технический комитет
- SC 46F - RF and microwave passive components
- SKU
- IEC 61169-67:2022
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61169-1:2013
ДействующийRadio frequency connectors - Part 1: Generic specification - General requirements and measuring methods
Overview - IEC 61169-1:2013 (Radio frequency connectors, Part 1) IEC 61169-1:2013 is the generic specification for radio frequency (RF) connectors used with RF transmission lines in telecommunication…
EN IEC 61169-1-3:2026
ДействующийRadio-frequency connectors - Part 1-3: Electrical test methods - Surge withstand - Surge protective devices b…
Overview EN IEC 61169-1-3:2026 specifies the performance requirements and testing methods for surge protective devices (SPDs) integrated into radio-frequency (RF) coaxial connectors. Issued by CLC, t…
IEC 61169-15:2021
ДействующийRadio-frequency connectors - Part 15: Sectional specification - RF coaxial connectors with inner diameter of…
Overview IEC 61169-15:2021 is an International Electrotechnical Commission (IEC) standard specifying requirements for radio-frequency (RF) coaxial connectors with an inner diameter of outer conductor…