IEC 61196-6:2009
Coaxial communication cables - Part 6: Sectional specification for CATV drop cables
Coaxial communication cables - Part 6: Sectional specification for CATV drop cables
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 11
- Дата публикации:
- 12 января 2009 г.
- Издание:
- IEC IS 61196 edition 1 version 1
- ICS:
- 33.120.10
IEC 61196-6:2009(E) applies to coaxial communications cables. It specifies the requirements for CATV drop cables for use in cabled television distribution networks operating at temperature between 40 °C and +70 °C and in the frequency range from 5 MHz to 1 000 MHz or from 5 MHz to 3 000 MHz. This publication is to be read in conjunction with IEC 61196-1:2005.
Abstract
Overview
IEC 61196-6:2009 - "Coaxial communication cables - Part 6: Sectional specification for CATV drop cables" defines requirements for coaxial CATV drop cables used in cabled television distribution networks. It applies to cables operating between −40 °C and +70 °C and in the frequency ranges 5 MHz–1 000 MHz or 5 MHz–3 000 MHz. This sectional specification is intended to be read in conjunction with IEC 61196-1 (generic requirements) and specifies construction, materials, electrical, environmental and mechanical performance criteria for CATV drop cables.
Key topics and technical requirements
- Cable construction and materials
- Inner conductor: single wire or tube; material and nominal diameter specified in detail specifications (max tolerance ±0.03 mm).
- Dielectric: type, diameter, ovality and eccentricity specified (diameter tolerance ±0.15 mm).
- Outer conductor/screen: construction and nominal diameter specified (tolerance ±0.20 mm).
- Sheath: thermoplastic outer sheath (where provided); nominal thickness and diameter specified (tolerance ±0.25 mm). For black polyethylene outdoor sheaths, carbon black content is specified.
- Electrical and transmission parameters
- Characteristic impedance: 75 Ω ± 3 Ω.
- Return loss requirements: ≥ 20 dB (5–1 000 MHz); progressively relaxed to ≥ 16 dB up to 3 000 MHz.
- Attenuation: defined by a frequency-dependent formula; discrete values provided in detail specifications (measurements at 200 MHz and 800 MHz often used).
- Screening / transfer impedance classes: Screening attenuation and transfer impedance limits define Screening Classes A+, A, B, C with specified dB and mΩ/m thresholds (triaxial test methods after flexure).
- Environmental and mechanical tests
- Temperature cycling, cold-bend, damp heat, UV stability (for outdoor), thermal ageing and optional water penetration tests.
- Mechanical tolerances for dielectric/sheath ovality and eccentricity, tensile/elongation and adhesion tests for dielectric-to-conductor bond.
- Identification and marking
- Cable type number and manufacturer markings applied to sheath or outer conductor; labelling per IEC 61196-1.
Applications and users
- Primary application: CATV drop cables connecting network taps to subscriber premises in cable television and related RF/broadband distribution systems.
- Typical users:
- Cable manufacturers specifying and certifying CATV drop products.
- System designers and network planners selecting cables for frequency and environmental requirements.
- Test laboratories performing IEC-conformant electrical, mechanical and environmental tests.
- Procurement and compliance teams ensuring product conformity to international standards.
Related standards
- IEC 61196-1 (Generic specification)
- IEC 61196-1-100, -200, -300, -400 series (test methods)
- IEC 62153 (metallic cable test methods)
- IEC 60068-1 (environmental testing)
- IEC 62230 (spark-test method)
Keywords: IEC 61196-6:2009, CATV drop cables, coaxial communication cables, cable specification, characteristic impedance, return loss, attenuation, screening classes, cable testing, IEC 61196-1.
Технические детали
- Технический комитет
- SC 46A - Coaxial cables
- SKU
- IEC 61196-6:2009
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61196-1-205:2008
ДействующийCoaxial communication cables - Part 1-205: Environmental test methods - Resistance to solvents and contaminat…
Overview IEC 61196-1-205:2008 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies environmental test methods for coaxial communication cables.…
IEC 61196-1-100:2015
ДействующийCoaxial communication cables - Part 1-100: Electrical test methods - General requirements
Overview IEC 61196-1-100:2015 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the general requirements and conditions for electrical testi…
IEC 62153-4-6:2017
ДействующийMetallic cables and other passive components test methods - Part 4-6: Electromagnetic compatibility (EMC) - S…
Overview - IEC 62153-4-6:2017 (Surface transfer impedance, Line injection method) IEC 62153-4-6:2017 is an international test method for evaluating the screening effectiveness of shielded metallic co…
IEC 60068-1:2013
ДействующийEnvironmental testing - Part 1: General and guidance
Overview IEC 60068-1:2013 is an internationally recognized standard developed by the International Electrotechnical Commission (IEC) that provides general guidance and fundamental principles for envi…