IEC 61267:2005
Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 85
- Дата публикации:
- 9 ноября 2005 г.
- Издание:
- IEC IS 61267 edition 2 version 1
- ICS:
- 11.040.50
This International Standard applies to test procedures which, for the determination of characteristics of systems or components of medical diagnostic X-ray equipment, require well-defined radiation conditions. Except for mammography, this standard does not apply to conditions where discontinuities in radiation absorption of elements are deliberately used to modify properties of the radiation beam (for example by rare earth filters). This standard deals with methods for generating radiation beams with radiation conditions which can be used under test conditions typically found in test laboratories or in manufacturing facilities for the determination of characteristics of medical diagnostic X-ray equipment. Examples of such radiation qualities are radiation beams emerging through the filtration from the X-ray source assembly. radiation conditions represent the more general case, where scattered radiation emerges from an exit surface of a patient or a phantom. This requires a well defined geometrical arrangement.
Abstract
Overview
IEC 61267:2005 is an international standard developed by the International Electrotechnical Commission (IEC) that defines radiation conditions for use in determining the characteristics of medical diagnostic X-ray equipment. This standard is essential for ensuring well-defined, reproducible radiation qualities in test procedures assessing the performance and safety of diagnostic radiology systems. It provides guidelines suitable for laboratory and manufacturing environments, enabling consistent evaluation of X-ray systems or components under controlled radiation conditions.
The standard excludes mammography and other applications where variations in radiation absorption by elements (such as special rare earth filters) are used deliberately to modify the radiation beam. Instead, IEC 61267:2005 focuses on typical radiation beams emerging through filtration in the X-ray source assembly or scattered radiation from patients or phantoms under clearly defined geometric arrangements.
Key Topics
- Scope and Application: Covers test procedures for defining radiation qualities to determine the performance characteristics of medical diagnostic X-ray equipment.
- Radiation Qualities: Defines different radiation qualities (RQR, RQA, RQC, RQT, RQN, RQB series) based on the nature of filtration and phantom use including aluminium and copper filters.
- Adjustment Procedures: Provides detailed methods for the generation and adjustment of radiation beams meeting standard conditions.
- Measurement Methods: Introduces the use of practical peak voltage (kVp) measurement for accurate assessment of X-ray tube voltage.
- Standardized Radiation Conditions: Specifies geometric configurations and radiation conditions to ensure repeatability and comparability in testing across laboratories.
- Normative and Informative Annexes: Includes comprehensive annexes covering rationale for choices, filtration determination, voltage measurement, and overview of radiation qualities.
Applications
IEC 61267:2005 serves as a foundational reference for multiple stakeholders within the medical imaging and radiology sectors:
- Manufacturers of Diagnostic X-ray Equipment: Utilizes the standard to ensure equipment complies with internationally accepted radiation conditions during design, development, and quality control testing.
- Medical Physicists and Test Laboratories: Applies the standardized radiation qualities to evaluate X-ray system performance, consistency, and safety, ensuring reliable diagnostic imaging results.
- Regulatory and Certification Bodies: References the standard for certification criteria and compliance verification related to radiation protection and device characterization.
- Healthcare Facilities and Service Providers: Supports equipment validation and acceptance testing to safeguard patient safety and optimize imaging quality.
By adhering to IEC 61267:2005, stakeholders can achieve enhanced reproducibility in X-ray testing, contribute to international harmonization in medical imaging standards, and ultimately support high standards of diagnostic accuracy and patient protection.
Related Standards
- IEC 60601 Series - Standards for the safety and essential performance of medical electrical equipment, including diagnostic X-ray systems.
- IEC 60522 - Radiation protection instrumentation specific to medical radiology.
- ISO 4037 - Reference radiation for calibrating dosemeters and doserate meters.
- IEC 60034-1 - Related electrotechnical standards covering measurement and test procedures for electrical equipment used in diagnostic devices.
- International guidelines on patient dose and radiation protection by IAEA and ICRP that complement the technical testing procedures outlined by IEC 61267.
Keywords: IEC 61267, medical diagnostic X-ray equipment, radiation conditions, radiation qualities, X-ray testing, diagnostic radiology, practical peak voltage, radiation beam filtration, X-ray equipment standards, test procedures, medical imaging compliance, radiology equipment characterization
Технические детали
- Технический комитет
- SC 62C - Equipment for radiotherapy, nuclear medicine and radiation dosimetry
- SKU
- IEC 61267:2005
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60601-2-91:2026
ДействующийMedical electrical equipment - Part 2-91: Particular requirements for basic safety and essential performance…
Overview IEC 60601-2-91:2026 specifies the particular requirements for the basic safety and essential performance of non-thermal plasma wound treatment equipment and associated accessories. Developed…
IEC 60522:1999
Determination of the permanent filtration of X-ray tube assemblies
ISO 4037-3:2019
ДействующийRadiological protection — X and gamma reference radiation for calibrating dosemeters and doserate meters and…
Overview ISO 4037-3:2019 - Radiological protection - Part 3 - provides detailed procedures and data for the calibration of area and personal dosemeters and doserate meters using X‑ and gamma‑ray refe…
IEC 60034-15:2025
ДействующийRotating electrical machines - Part 15: Impulse voltage withstand levels of form-wound stator coils for rotat…
Overview IEC 60034-15:2025 (Rotating electrical machines - Part 15: Impulse voltage withstand levels of form-wound stator coils for rotating a.c. machines) specifies the impulse voltage withstand req…
IEC 61267:2025
ДействующийMedical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
Overview IEC 61267:2025 - Medical diagnostic X‑ray equipment - Radiation conditions for use in the determination of characteristics defines standardized X‑ray radiation conditions and methods for gen…