IEC 61290-1-1:2020
Optical amplifiers - Test methods - Part 1-1: Power and gain parameters - Optical spectrum analyzer method
Optical amplifiers - Test methods - Part 1-1: Power and gain parameters - Optical spectrum analyzer method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 58
- Дата публикации:
- 3 сентября 2020 г.
- Издание:
- IEC IS 61290 edition 4 version 1
- ICS:
- 33.180.30
IEC 61290-1-1:2020 applies to all commercially available optical amplifiers (OAs) and optically amplified modules. It applies to OAs using optical fibre amplifiers (OFAs) based on either rare-earth doped fibres or on the Raman effect, semiconductor OAs (SOAs) and planar optical waveguide amplifiers (POWAs). The object of this document is to establish uniform requirements for accurate and reliable measurements, by means of the optical spectrum analyzer (OSA) test method, of the following OA parameters, as defined in IEC 61291-1: - nominal output signal power; - gain; - polarization-dependent gain (PDG); - maximum output signal power; - maximum total output power. In addition, this document provides the test method of: - gain ripple (for SOAs). NOTE All numerical values followed by (‡) are suggested values for which the measurement is assured. The object of this document is specifically directed to single-channel amplifiers. Test methods for multichannel amplifiers are standardized in IEC 61290-10 (all parts). This fourth edition cancels and replaces the third edition published in 2015 and constitutes a technical revision. This edition includes the following significant technical change with respect to the previous edition: addition of techniques to test gain ripple of SOAs.
Abstract
Overview
IEC 61290-1-1:2020 defines the optical spectrum analyzer (OSA) test method for measuring power and gain parameters of single‑channel optical amplifiers (OAs). This fourth edition (2020) applies to commercially available optical fibre amplifiers (rare‑earth doped and Raman), semiconductor optical amplifiers (SOAs), and planar optical waveguide amplifiers (POWAs). The standard establishes uniform requirements for accurate, repeatable measurements of key amplifier metrics using an OSA-based test setup.
Key topics and technical requirements
-
Measured parameters
- Nominal output signal power
- Gain
- Polarization‑dependent gain (PDG)
- Maximum output signal power
- Maximum total output power
- Gain ripple (specific test method for SOAs)
-
Scope and focus
- Directed at single‑channel amplifiers; multichannel test methods are covered in IEC 61290‑10 (all parts).
- Numerical values marked with (‡) are suggested values for assured measurement performance.
-
Test method and apparatus
- Uses an optical spectrum analyzer (OSA) as the core measurement instrument.
- Typical test setup components: optical source (fixed or tunable), polarization controller, variable optical attenuator, optical power meter (for calibration), and the OSA.
- Required source characteristics (suggested): full width at half maximum (FWHM) < 1 nm; side‑mode suppression > 30 dB for DFB/DBR/ECL lasers; output power fluctuation < 0.05 dB; source-to-spontaneous-emission power ratio > 30 dB.
- Procedures for calibration, input/output power measurement, PDG variation, maximum output power tests, and two gain ripple methods (signal gain method and ASE method) are specified.
-
Calculations and reporting
- Defines calculation methods for nominal output, gain, PDG, maximum output metrics, and gain ripple spectra.
- Specifies required apparatus characteristics and reporting of test results for reproducibility.
Practical applications and who uses this standard
- Manufacturers of OFAs, SOAs, POWAs use the standard to validate product specifications and ensure consistent production testing.
- Test laboratories and QA teams adopt the OSA method for certification, acceptance testing, and comparative benchmarking.
- System integrators and designers rely on the defined parameters (gain, PDG, max output power, gain ripple) to select amplifiers compatible with single‑channel links and to predict link performance.
- R&D engineers use the gain ripple procedures (especially for SOAs) to characterize spectral flatness and noise implications.
Related standards
- IEC 61290‑1 (general test methods)
- IEC 61291‑1 (generic specification for optical amplifiers)
- IEC 61290‑10 series (multichannel amplifier test methods)
Keywords: IEC 61290‑1‑1, optical amplifiers, optical spectrum analyzer, OSA test method, gain ripple, SOA, PDG, optical amplifier testing, OFA, POWA.
Технические детали
- Технический комитет
- SC 86C - Fibre optic systems, sensing and active devices
- SKU
- IEC 61290-1-1:2020
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61290-10-1:2009
ДействующийOptical amplifiers - Test methods - Part 10-1: Multichannel parameters - Pulse method using an optical switch…
Overview IEC 61290-10-1:2009 is an international standard published by the International Electrotechnical Commission (IEC) that specifies test methods for optical amplifiers (OAs) using rare-earth do…
IEC 61290-1-2:2026
ДействующийOptical amplifiers - Test methods - Part 1-2: Power and gain parameters - Electrical spectrum analyzer method
Overview IEC 61290-1-2:2026 specifies test methods for measuring power and gain parameters of optical amplifiers (OAs) using the electrical spectrum analyzer (ESA) method. Developed by the Internatio…
IEC 61291-1:2018
ДействующийOptical amplifiers - Part 1: Generic specification
Overview The IEC 61291-1:2018 standard, titled Optical Amplifiers - Part 1: Generic Specification, is an international standard published by the International Electrotechnical Commission (IEC). It pr…
IEC 61290-11-2:2005
ДействующийOptical amplifiers - Test methods - Part 11-2: Polarization mode dispersion parameter - Poincaré sphere analy…
Overview IEC 61290-11-2:2005 specifies standardized test methods for measuring the polarization mode dispersion (PMD) parameter in optical amplifiers (OAs), including optical fibre amplifiers (OFAs)…