IEC 61300-3-22:2010
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-22: Examinations and measurements - Ferrule compression force
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-22: Examinations and measurements - Ferrule compression force
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 13
- Дата публикации:
- 9 декабря 2010 г.
- Издание:
- IEC IS 61300 edition 2 version 1
- ICS:
- 33.180.20
IEC 61300-3-22:2010 describes the procedure to measure the spring-loaded force applied to a ferrule when the plugs mate with each other during normal service. This measurement procedure is applicable to a connector plug which has a spring-loaded ferrule. Changes from the previous edition include reconsideration of the procedure and the details to be specified.
Abstract
Overview
IEC 61300-3-22:2010 is an international standard developed by the International Electrotechnical Commission (IEC) under technical committee 86B, specializing in fibre optic interconnecting devices and passive components. This standard specifically addresses the measurement of ferrule compression force in spring-loaded fibre optic connector plugs during their normal mating process.
The standard provides a basic test and measurement procedure to accurately quantify the spring-loaded force applied to ferrules, which is crucial for ensuring optimal optical performance and mechanical reliability in fibre optic connections. It replaces the first edition from 1997, reflecting updated testing methodology and details to be specified by manufacturers or testing bodies.
Key Topics
-
Scope and Applicability
IEC 61300-3-22 applies to connector plugs with spring-loaded ferrules, focusing on the compressive forces exerted during connection mating, which can influence insertion loss and connector durability. -
Test Apparatus
- Fixed clamping device to securely hold the device under test (DUT) without mechanically altering ferrule properties.
- Force generator capable of applying a smooth compressive load at a controlled rate (e.g., 5 mm/min).
- Position sensor for measuring ferrule end-face displacement accurately.
- Force gauge to measure the compressive force applied to the ferrule end face.
-
Measurement Procedure
- Secure the DUT in the clamping device following the manufacturer’s preparation instructions.
- Apply axial compressive load to the ferrule smoothly until the ferrule end face reaches the specified position relative to the connector mechanical reference.
- Record the spring-loaded compression force at the defined ferrule end-face displacement as indicated in relevant fibre optic connector interface standards (IEC 61754 series).
-
Specification Details
The standard requires specification of the following in detail specifications:- Performance requirements according to IEC 61754 parts.
- Exact ferrule end-face position relative to connector mechanical reference plane.
- Target spring force values at the specified ferrule positions.
- Any deviations from the standard test procedure.
- Cable types used (buffered fibre or primary coated fibre) in the connector assembly.
Applications
IEC 61300-3-22 serves an important role for manufacturers, testing laboratories, and quality control teams involved in the development and validation of fibre optic connectors with spring-loaded ferrules. Typical applications include:
-
Quality Assurance of Fiber Optic Connectors
Ensuring correct ferrule compression force guarantees reliable mechanical coupling and stable optical performance over connector lifecycle. -
Connector Design Verification
Validating that the spring-loaded ferrule applies the intended force during mating, helping to avoid issues like excessive insertion loss or connector damage. -
Performance Benchmarking
Comparing ferrule compression forces of new connector designs or batches against established specifications for standard compliance. -
Failure Analysis and Durability Testing
Analyzing variations in compression force can aid in diagnosing connector wear or mechanical failure over time.
These practical applications directly contribute to enhanced network reliability, minimized signal loss, and improved overall system performance in fibre optic communications.
Related Standards
-
IEC 61754 Series
Defines fibre optic connector interfaces, specifying critical mechanical reference points used in measuring ferrule compression force according to IEC 61300-3-22. These interface standards provide dimensional details necessary for compliance testing. -
IEC 61300 Series
Encompasses a broad set of basic test and measurement procedures for fibre optic interconnecting devices and passive components, of which Part 3-22 is a specific segment focusing on ferrule compression force. -
ISO/IEC Directives, Part 2
Governs the development and drafting of IEC standards ensuring consistency and international applicability.
Adhering to IEC 61300-3-22:2010 supports conformity to international best practices in fibre optic connector testing, reinforcing product reliability and interoperability across global markets.
By implementing the procedures in IEC 61300-3-22, companies can assure the consistent performance of spring-loaded ferrule connectors, reduce field failures, and maintain robust fibre optic network infrastructure. This standard remains essential for professionals seeking precision in fibre optic interconnection testing and measurement.
Технические детали
- Технический комитет
- SC 86B - Fibre optic interconnecting devices and passive components
- SKU
- IEC 61300-3-22:2010
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61300-3-2:2009
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2…
Overview IEC 61300-3-2:2009 - "Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Polarization dependent loss in a single-mode fibre optic…
IEC 61754-4:2022
ДействующийFibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 4: Type…
Overview IEC 61754-4:2022 defines the standard mechanical interface dimensions for the SC (Subscriber Connector) family of fibre‑optic connectors. This third edition (2022) replaces the 2013 edition…
IEC 61300-2-33:2026
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-3…
Overview IEC 61300-2-33:2026 is an international standard developed by the International Electrotechnical Commission (IEC). It specifies basic test and measurement procedures for fibre optic intercon…