IEC 61935-2:2010
Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards
Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 55
- Дата публикации:
- 12 июля 2010 г.
- Издание:
- IEC IS 61935 edition 3 version 1
- ICS:
- 33.040.20
IEC 61935-2:2010 provides methods to ensure compatibility of balanced cords to be used in cabling according to ISO/IEC 11801 and provides test methods and associated requirements to demonstrate the performance and reliability of these balanced cords during their operational lifetime. This International Standard may also be used for providing test methods for assessing the behaviour of other balanced cords. This third edition cancels and replaces the second edition published in 2005. It differs from the second edition in that it covers category 6A to category 7A cords as defined in ISO/IEC 11801.
Abstract
Overview
IEC 61935-2:2010 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies testing methods for balanced cords used in information technology cabling systems. Covering cords as specified in ISO/IEC 11801 and related standards, this third edition updates the testing framework to include balanced cords from Category 6A to Category 7A. The standard ensures the compatibility, performance, and reliability of these cords during their operational lifetime.
Balanced cords play a critical role in connecting IT equipment through free connectors defined by IEC 60603-7 series and related connector standards. Given that connecting hardware performance is influenced by cord terminations and manufacturing quality, IEC 61935-2:2010 provides comprehensive test procedures that help manufacturers and network deployers guarantee the quality and functionality of these essential components in structured cabling systems.
Key Topics
-
Test Scope and Configuration
The standard covers balanced cords incorporating twisted pairs terminated with free connectors. It includes test setups, cable and connector design criteria, and details on test equipment configurations essential for consistent measurements. -
Performance Tests
Key electrical property evaluations include:- Insertion loss
- Return loss
- Near End Crosstalk (NEXT)
- Propagation delay and delay skew
-
Acceptance and Periodic Testing
The document sets requirements for:- Visual inspection and wire map verification to detect physical defects and wiring accuracy
- Mechanical tests including tensile strength, flexure, bending, twisting, and crushing to verify durability under normal usage
- Environmental tests such as dust exposure and climatic sequences to assess cord robustness in different conditions
-
Test Head Requirements
The standard details minimum specifications for test heads used in the evaluation process, ensuring precise loss centering, return loss measurement, and crosstalk properties. -
Cord Categories Supported
IEC 61935-2:2010 extends testing methodology to support advanced cabling categories conforming to ISO/IEC 11801 standards, spanning Category 6A through Category 7A cords.
Applications
-
Structured Cabling Systems
Designed for use in enterprise networks, data centers, and telecommunications facilities, the standard helps maintain the performance integrity of balanced cords within structured cabling infrastructures. -
Manufacturing Quality Control
Cable manufacturers use these test methods during production to validate cord assemblies and ensure they meet stringent performance criteria for high-speed data transmission. -
Network Equipment Compatibility
Ensures balanced cords seamlessly connect IT equipment according to international interoperability standards, preventing signal degradation or failures due to poor cable assembly or component mismatch. -
Reliability Assurance Across Cord Lifespan
The mechanical and environmental test methods help predict and verify cord durability, ensuring dependable network operation under varying installation and operational conditions.
Related Standards
-
ISO/IEC 11801 – International standard defining generic cabling for customer premises, specifying cabling system architectures including balanced cords.
-
IEC 60603-7 Series – Standard series covering connectors for balanced copper cabling, critical for physical interface specifications.
-
IEC 61076-3-104 and IEC 61076-3-110 – Standards focusing on specific free connector types used in balanced cords.
-
IEC 61935-1 – Part 1 of the series specifying testing of balanced and coaxial cabling, dealing primarily with permanent links.
By applying IEC 61935-2:2010, stakeholders can ensure balanced cords meet internationally recognized technical and quality benchmarks, supporting high-performance and robust IT infrastructure cabling deployments worldwide.
Технические детали
- Технический комитет
- TC 46 - Cables, wires, waveguides, RF connectors, RF and microwave passive components and accessories
- SKU
- IEC 61935-2:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO/IEC 11801-6:2017
ДействующийInformation technology — Generic cabling for customer premises — Part 6: Distributed building services
Overview ISO/IEC 11801-6:2017 - "Information technology - Generic cabling for customer premises - Part 6: Distributed building services" specifies generic cabling for premises that comprise single or…
IEC 60603-7-3:2010
ДействующийConnectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed conn…
Overview IEC 60603-7-3:2010 is an international standard published by the International Electrotechnical Commission (IEC) that defines detailed specifications for 8-way, shielded, free and fixed conn…
IEC 61076-3-104:2017
ДействующийConnectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification…
Overview IEC 61076-3-104:2017 is an internationally recognized standard developed by the International Electrotechnical Commission (IEC). It specifies product requirements for 8-way, shielded free an…
IEC 61076-3-110:2012
ДействующийConnectors for electronic equipment - Product requirements - Part 3-110: Detail specification for shielded, f…
Overview IEC 61076-3-110:2012 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the requirements for shielded, free, and fixed connectors us…
IEC 61935-1:2015
ДействующийSpecification for the testing of balanced and coaxial information technology cabling - Part 1: Installed bala…
Overview IEC 61935-1:2015 specifies reference measurement procedures and field tester accuracy requirements for installed balanced information‑technology cabling as defined in ISO/IEC 11801 and equiv…