IEC 62667:2017 applies to light ion beam ME equipment when used, for therapy purposes, in human medical practice. This document applies to light ion beam ME equipment which delivers light ion beams with an energy per nucleon in the range 10 MeV/n to 500 MeV/n. This document describes measurements and test procedures to be performed by the manufacturer of light ion beam ME equipment but does not specify acceptance tests. This document specifies test procedures for the determination and disclosure of performance characteristics, knowledge of which is necessary for proper selection, application, and use of light ion beam ME equipment and which are to be declared in the accompanying documentation together with the greatest deviation or variation to be expected under specific conditions in normal use. A format for presentation of performance values is given in Annex A.
Abstract
Overview
IEC 62667:2017 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the performance characteristics of medical electrical equipment utilizing medical light ion beam technology. This standard applies specifically to light ion beam medical electrical (ME) equipment used in therapeutic treatments in human medical practice. It covers equipment delivering light ion beams with energies ranging from 10 MeV/n to 500 MeV/n per nucleon.
The document outlines the necessary measurements and test procedures that manufacturers must perform to determine and declare the performance characteristics of light ion beam ME equipment. These declared characteristics enable healthcare providers to properly select, apply, and use the equipment in clinical environments. However, the standard does not specify acceptance testing protocols.
Key Topics
- Scope and Application: Defines the types of light ion beam equipment covered and the operational energy ranges relevant to medical therapy.
- Beam Delivery: Detailed descriptions of ion species, energy selection methods, beam gating, gantry types and configurations, beam applicators, adjustable beam limiting devices (BLDs), isocenter definitions, lateral spreading devices (LSDs), and scanning modes.
- Time Constraints: Specifies maximum irradiation time, switching times between irradiations, energies, and ion species, as well as start-up and shutdown times.
- Dose Monitoring System: Requirements and test procedures for dose monitoring systems including reproducibility, proportionality, off-axis response, angular dependency, and dose stability over different time frames.
- Depth Dose Characteristics: Performance evaluation of depth dose distributions, range modulation techniques, and stability of light ion beam range.
- Lateral Profiles: Assessment of lateral beam profiles including flatness, symmetry, and penumbra for both scattering and scanning beam systems.
- Energy and Fluence Modulation: Description of energy and fluence modulated portals including performance for low-dose delivery.
- Radiation Field Indication: Requirements for clear indication of radiation fields, positioning of beam limiting devices, and reference axis alignment.
- Environmental and Maintenance Conditions: Consideration of transport, storage, facility stability, and equipment maintenance for ensuring consistent performance.
- Presentation of Information: Guidelines for manufacturers on providing clear, standardized performance data and user instructions in accompanying documentation.
Applications
IEC 62667:2017 is crucial for medical device manufacturers, healthcare providers, and regulatory bodies involved in the production, evaluation, and use of medical light ion beam equipment. The standard ensures:
- Safety and Efficacy of Treatment: By defining test procedures to verify the accuracy and reliability of ion beam delivery, the standard supports effective and safe patient therapy.
- Device Performance Transparency: Manufacturers must declare key performance indicators, enhancing clinician confidence and facilitating informed decision-making regarding device selection and application.
- Regulatory Compliance: Acts as a benchmark for regulatory assessment processes for medical light ion beam equipment, aligning global safety and performance expectations.
- Clinical Operational Efficiency: Time constraints and equipment switching parameters help optimize clinical workflow without compromising treatment quality.
- Quality Assurance: Detailed measurement protocols enable consistent performance verification and support ongoing quality maintenance in medical facilities.
Related Standards
For comprehensive compliance and integration, IEC 62667:2017 is often used alongside other IEC and international standards for medical electrical equipment and radiation therapy, such as:
- IEC 60601 series: Essential standards for basic safety and essential performance of medical electrical equipment.
- IEC/TR 60976: Radiation therapy equipment including proton and ion beam therapy technical reports.
- ISO 13485: Quality management systems for medical device manufacturers.
- IEC 61784: Industrial communication networks standards relevant to equipment integration and monitoring.
- Regional Regulatory Guidelines: FDA (USA), EMA (Europe), and other national bodies' regulations on medical ionizing radiation devices.
Keywords: IEC 62667, medical light ion beam equipment, performance characteristics, medical electrical equipment, ion beam therapy, dose monitoring, beam delivery, radiation safety, medical device standards, ion therapy equipment testing, radiation therapy standards, gantry configurations.
Технические детали
- Технический комитет
- SC 62C - Equipment for radiotherapy, nuclear medicine and radiation dosimetry
- SKU
- IEC 62667:2017
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60601-2-91:2026
ДействующийMedical electrical equipment - Part 2-91: Particular requirements for basic safety and essential performance…
Overview IEC 60601-2-91:2026 specifies the particular requirements for the basic safety and essential performance of non-thermal plasma wound treatment equipment and associated accessories. Developed…
ISO 14969:1999
ОтменёнQuality systems — Medical devices — Guidance on the application of ISO 13485 and ISO 13488
IEC 61784-2-21:2023
ДействующийIndustrial networks - Profiles - Part 2-21: Additional real-time fieldbus profiles based on ISO/IEC/IEEE 8802…
Overview IEC 61784-2-21:2023 is an international standard developed by the International Electrotechnical Commission (IEC) that defines Communication Profile Family 21 (CPF 21). This profile family s…