IEC 63267-2-2:2024
Fibre optic interconnecting devices and passive components - Connector optical interfaces for enhanced macro bend multimode fibres - Part 2-2: Connection parameters of physically contacting 50 μm core diameter fibres - Non-angled and angled for reference connector applications
Fibre optic interconnecting devices and passive components - Connector optical interfaces for enhanced macro bend multimode fibres - Part 2-2: Connection parameters of physically contacting 50 μm core diameter fibres - Non-angled and angled for reference connector applications
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 25
- Дата публикации:
- 15 марта 2024 г.
- Издание:
- IEC IS 63267 edition 1 version 1
- ICS:
- 33.180.20
IEC 63267-2-2:2024 defines the dimensional limits of an optical interface for reference connections necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled and angled polished multimode reference connectors intended to be used for attenuation measurements in the field or factory. Several grades of reference connections are defined in this document. The multimode reference connections are terminated to restricted IEC 60793-2-10 A1-OM2b to A1-OM5b fibre at the 850 nm band only. The geometrical dimensions and tolerances of the specified reference connections have been developed primarily to limit the variation in measured attenuation between multiple sets of two reference connectors, and therefore to limit the variation in measured attenuation between randomly chosen reference connectors when mated with connectors in the field or factory.
Abstract
Overview
IEC 63267-2-2:2024 is an international standard by the International Electrotechnical Commission (IEC) that specifies the dimensional limits and connection parameters for physically contacting fibre optic connectors with a 50 μm core diameter. This standard addresses both non-angled (PC) and angled (APC) polished multimode reference connectors intended for applications where accurate attenuation measurements are critical, such as in the field or in manufacturing environments. The standard is crucial for ensuring consistent performance and low measurement uncertainty between reference connectors, particularly for enhanced macro bend multimode fibres operating at the 850 nm wavelength.
Key Topics
- Dimensional Specifications: Sets out strict tolerances for geometrical dimensions and alignment to minimize variability in measured attenuation.
- Performance Grades: Defines several grades of reference connections to accommodate different connector types and applications. Attenuation levels for each grade are specified at 850 nm.
- Fibre Types: Applies specifically to reference connectors terminated to multimode optical fibres within the restricted IEC 60793-2-10 A1-OM2b to A1-OM5b categories.
- Attenuation Measurement: Emphasizes the importance of using reference-grade connectors for accurate attenuation measurements, providing detailed guidance to limit measurement uncertainty.
- Visual Inspection Requirements: Outlines inspection criteria based on IEC 61300-3-35 for fibre end face quality in reference connectors, with specific requirements for defect and scratch sizes.
- Measurement Uncertainty Contributions: Details sources of variability, including geometry mismatch and measurement setup, and provides methods for uncertainty calculation.
Applications
IEC 63267-2-2:2024 is highly relevant for professionals involved in the testing, manufacturing, and certification of fibre optic components and systems, especially where attenuation measurements are required to be highly reproducible. Key application areas include:
- Factory and Field Attenuation Testing: Used to define consistent reference connector interfaces to ensure accurate loss measurements when certifying or troubleshooting multimode fibre links.
- Quality Assurance in Manufacturing: Supports the production of high-quality fibre optic connectors and cable assemblies, ensuring connector consistency across batches and minimizing measurement discrepancies.
- Connector and Cable Characterization: Facilitates comparative testing of different connector types under controlled conditions, providing reliable reference standards.
- Network Installation and Maintenance: Assists field technicians by supplying standardized reference connectors, reducing uncertainty during network acceptance testing or maintenance.
Related Standards
For comprehensive compliance and best practices in fibre optic connector interface design and testing, the following related IEC standards should be considered:
- IEC 60793-2-10: Product specifications for category A1 multimode fibres, providing the base requirements for fibre types applicable in IEC 63267-2-2.
- IEC 61300-3-35: Procedures for visual inspection of fibre optic connectors; referenced for end face inspection criteria.
- IEC 61300-3-4: Examines recommendations for fibre optic attenuation measurement methods.
- IEC 61300-1: General guidance on test and measurement procedures for fibre optic passive components.
- IEC 62614 (all parts): Details multimode launch conditions impacting measurement accuracy.
- IEC 63267 (all parts): Addresses connector optical interfaces for enhanced macro bend multimode fibre.
- IEC TR 62627-04: Guide for uncertainty calculation in attenuation measurement.
- IEC TR 61282-14: Methods for determining uncertainties of attenuation measurements in optical fibre plants.
Practical Value
Adopting IEC 63267-2-2:2024 enables manufacturers, test laboratories, and installers to achieve low and consistent measurement uncertainty in fibre optic attenuation, contributing to reliable network performance and interoperability. The standard’s approach to limiting dimension and alignment tolerances ensures that connectors selected as reference units deliver reproducible results, thus supporting quality control and compliance with international best practices in fibre optic communication infrastructure.
Keywords: IEC 63267-2-2:2024, fibre optic connectors, multimode reference connectors, attenuation measurement, macro bend fibres, 50 μm core, connector optical interface standard, optical fibre interconnection, performance grades, IEC standards, measurement uncertainty.
Технические детали
- Технический комитет
- SC 86B - Fibre optic interconnecting devices and passive components
- SKU
- IEC 63267-2-2:2024
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60793-2-10:2019
ДействующийOptical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres
Overview IEC 60793-2-10:2019 defines product specifications for category A1 multimode optical fibres - covering the sub-categories A1-OM1, A1-OM2, A1-OM3, A1-OM4, A1-OM5, and A1d. This seventh-editio…
IEC 61300-3-35:2015
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3…
Overview IEC 61300-3-35:2015 defines standardized visual inspection and quantitative assessment methods for the end face quality of a polished fibre optic connector and for fibre optic transceivers u…
IEC 61300-3-45:2011
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4…
Overview IEC 61300-3-45:2011 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies basic test and measurement procedures for fibre optic interco…
IEC 61300-1:2022
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1:…
Overview IEC 61300-1:2022 (consolidated with amendments to 2025) is the general guidance document for basic test and measurement procedures applied to fibre optic interconnecting devices and passive…