IEC 80601-2-30:2018
Medical electrical equipment — Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers
Medical electrical equipment — Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 104
- Дата публикации:
- 23 марта 2018 г.
- Издание:
- IEC IS 80601 edition 2 version 1
- ICS:
- 11.040.10
IEC 80601-2-30:2018 applies to the basic safety and essential performance of automated sphygmomanometers, hereafter referred to as ME equipment, which by means of an inflatable cuff, are used for non continuous indirect estimation of the blood pressure without arterial puncture. This document specifies requirements for the basic safety and essential performance for this ME equipment and its accessories, including the requirements for the accuracy of a determination. This document covers automatic electrically-powered ME equipment used for the intermittent, indirect estimation of the blood pressure without arterial puncture, including blood pressure monitors for the home healthcare environment. Requirements for indirect estimation of the blood pressure without arterial puncture ME equipment with an electrically-powered pressure transducer and/or displays used in conjunction with a stethoscope or other manual methods for determining blood pressure (non-automated sphygmomanometers) are specified in document ISO 81060-1. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 201.11 and 201.105.3.3, as well as 7.2.13 and 8.4.1 of IEC 60601-1:2005. This second edition cancels and replaces the first edition published in 2009 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with IEC 60601-1:2005/AMD1:2012 and IEC 60601-1-8:2006/AMD1:2012 , and with IEC 60601-1-2:2014 and IEC 60601-1-11:2015; b) referencing IEC 60601-1-10:2007 and IEC 60601-1-12; c) changing an operator-accessible cuff-sphygmomanometer connector from not compatible with the ISO 594 series to compatible with the ISO 80369 series; d) added additional requirements for public self-use sphygmomanometers; e) added a list of primary operating functions.
Abstract
Overview
IEC 80601-2-30:2018 is the international standard that details the particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers. This standard, developed by ISO and the International Electrotechnical Commission (IEC), focuses on medical electrical equipment used for the non-continuous, indirect estimation of blood pressure in patients, primarily through the use of an inflatable cuff. Intended for devices operated in clinical, home healthcare, and public self-use environments, the standard outlines critical safety, performance, and labeling requirements to ensure accurate, reliable, and safe blood pressure measurements without arterial puncture.
Key Topics
- Basic Safety and Essential Performance: Sets out the requirements that automated sphygmomanometers must meet to protect users and patients from risks associated with electrical, mechanical, or other hazards.
- Accuracy Requirements: Includes provisions for the precision and reliability of blood pressure determinations, ensuring that measurement results are valid for clinical and home-use decision making.
- Device Modes and Functions:
- Long-term automatic mode
- Short-term automatic mode
- Self-measurement mode for public self-use
- Neonatal mode for infants and neonates
- Cuff and Connector Standards:
- Specifications for the design and compatibility of cuffs
- Updated requirements for connectors, now referencing ISO 80369 series
- Electromagnetic Compatibility (EMC): Defines the device's immunity and emission requirements to prevent interference with other medical and electronic equipment.
- Labeling and Documentation: Comprehensive guidelines for outside markings, user documentation, and technical descriptions to ensure safe operation and maintenance.
- Usability: Addresses human factors engineering and interface requirements, especially important for home and self-use sphygmomanometers.
- Technical Revisions:
- Alignment with recent versions of IEC 60601 collateral standards on safety, EMC, usability, and home healthcare requirements.
- Additional requirements for public self-use devices and a clear list of primary operating functions.
Applications
IEC 80601-2-30:2018 applies across a wide range of healthcare settings where accurate, automated blood pressure measurement is necessary, including:
- Hospitals and Clinics: Automated sphygmomanometers used by healthcare professionals for patient monitoring.
- Home Healthcare: Blood pressure monitors intended for layperson use, supporting chronic disease management and early detection of hypertension.
- Public Self-Use Kiosks: Devices in pharmacies, clinics, or public spaces that allow users to self-monitor blood pressure safely and accurately.
- Emergency and Mobile Care: Equipment designed for portable and reliable blood pressure estimation during emergency medical services.
By adhering to this standard, manufacturers ensure their automated sphygmomanometers meet the essential requirements for performance, safety, and usability, supporting patient outcomes and regulatory compliance.
Related Standards
For a comprehensive approach to blood pressure measurement device compliance, the following related international standards should also be considered:
- IEC 60601-1: General requirements for basic safety and essential performance of medical electrical equipment.
- IEC 60601-1-2: Electromagnetic disturbances - requirements and tests.
- IEC 60601-1-6: Usability engineering for medical devices.
- IEC 60601-1-10: Requirements for physiologic closed-loop controllers.
- IEC 60601-1-11: Requirements for home healthcare environments.
- IEC 60601-1-12: Emergency medical services requirements.
- ISO 81060-1: Requirements for non-automated sphygmomanometers (manual devices).
- ISO 81060-2: Clinical investigation of automated measurement types.
- ISO 80369-1 and ISO 80369-5: Small-bore connectors for liquids and gases in healthcare applications, specifically limb cuff inflation.
Implementing IEC 80601-2-30:2018 helps manufacturers and healthcare providers respond effectively to regulatory expectations while promoting the safe and accurate use of automated blood pressure monitors worldwide.
Технические детали
- Технический комитет
- ISO/TC 121/SC 3 - Respiratory devices and related equipment used for patient care
- SKU
- IEC 80601-2-30:2018
Похожие стандарты
Стандарты, упомянутые в описании
ISO 80369-20:2015
ДействующийSmall-bore connectors for liquids and gases in healthcare applications -- Part 20: Common test methods
Overview - ISO 80369-20:2015 (Common test methods for small-bore connectors) ISO 80369-20:2015 defines the common test methods used to evaluate the performance requirements of small-bore connectors f…
IEC 60601-2-91:2026
ДействующийMedical electrical equipment - Part 2-91: Particular requirements for basic safety and essential performance…
Overview IEC 60601-2-91:2026 specifies the particular requirements for the basic safety and essential performance of non-thermal plasma wound treatment equipment and associated accessories. Developed…
IEC TR 62348:2012
ДействующийAssessment of the impact of the most significant changes in Amendment 1 to IEC 60601-1:2005 and mapping of th…
Overview IEC TR 62348:2012 is a Technical Report from the International Electrotechnical Commission that helps users transition from IEC 60601-1:2005 (Edition 3) to the amended edition (Amendment 1:2…
IEC 60601-1-2:2014
ДействующийMedical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Co…
Overview IEC 60601-1-2:2014, published by the International Electrotechnical Commission (IEC), defines the requirements and tests relating to the basic safety and essential performance of medical ele…
IEC 60601-1-11:2015
ДействующийMedical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - C…
Overview IEC 60601-1-11:2015 is the IEC collateral standard that specifies additional requirements for the basic safety and essential performance of medical electrical equipment (ME equipment) and me…
IEC 60601-1-12:2014
ДействующийMedical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - C…
Overview IEC 60601-1-12:2014 is an international collateral standard under the IEC 60601-1 series, developed by the International Electrotechnical Commission (IEC). This standard sets forth general r…
ISO 81060-1:2007
ДействующийNon-invasive sphygmomanometers — Part 1: Requirements and test methods for non-automated measurement type
Overview ISO 81060-1:2007 defines safety, performance and test-method requirements for non-automated sphygmomanometers (manual blood pressure devices). The standard applies to devices that use inflat…
ISO 81060-2:2018
ДействующийNon-invasive sphygmomanometers - Part 2: Clinical investigation of intermittent automated measurement type
Overview ISO 81060-2:2018 specifies requirements and methods for the clinical investigation of intermittent non‑invasive automated sphygmomanometers (cuff‑based devices that estimate arterial blood p…