IEC TR 62271-302:2010
High-voltage switchgear and controlgear - Part 302: Alternating current circuit-breakers with intentionally non-simultaneous pole operation
High-voltage switchgear and controlgear - Part 302: Alternating current circuit-breakers with intentionally non-simultaneous pole operation
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 133
- Дата публикации:
- 21 июня 2010 г.
- Издание:
- IEC TR 62271 edition 1 version 1
- ICS:
- 29.130.10
IEC/TR 62271-302:2010 provides guidance on the design, construction, specification and testing of circuit-breakers with intentional non-simultaneous pole operation which are excluded from the scope of IEC 62271-100. In all other respects the scope of this technical report is identical to that of IEC 62271-100. This technical report provides supplementary information and guidance for this type of circuit-breaker and is intended to be used in conjunction with IEC 62271-100. This publication is to be read in conjunction with IEC 62271-100:2008.
Abstract
Overview
IEC TR 62271-302:2010 is a technical report published by the International Electrotechnical Commission (IEC) that focuses on high-voltage alternating current (AC) circuit-breakers with intentionally non-simultaneous pole operation. This specialized circuit-breaker type is excluded from the scope of the IEC 62271-100 standard, which covers conventional AC circuit-breakers with simultaneous pole operation. IEC TR 62271-302 provides detailed guidance on design, construction, specification, testing, and operation of these circuit-breakers to ensure safety, reliability, and performance.
The document complements and is intended to be used alongside IEC 62271-100:2008, sharing much of its scope and technical foundations except for intentional non-simultaneous pole operation. This report is critical for manufacturers, designers, testing laboratories, and end-users involved in high-voltage switchgear systems where controlled timing between pole operations is crucial.
Key Topics
-
Scope and Application
The report addresses AC circuit-breakers specifically designed to operate poles in a deliberately non-simultaneous manner. This feature is significant in certain electrical network applications where synchronizing pole operations would result in undesirable switching transients. -
Design and Construction Requirements
- Materials such as gases and liquids used within the circuit-breaker
- Earthing, interlocking, and auxiliary equipment specifications
- Mechanical and electrical operating mechanisms such as stored energy apparatus
- Degrees of protection including gas, vacuum, and liquid tightness
- Electromagnetic compatibility and safety considerations
-
Performance and Testing
- Dielectric tests, temperature rise tests, and mechanical endurance
- Short-circuit making and breaking tests including special tests for non-simultaneous poles
- Verification of timing differences between poles and their impact on switching performance
- Controlled switching tests aimed at optimizing closing and breaking instants to minimize switching transients and equipment stress
-
Operating Characteristics
- Guidance on simultaneity and delay timings between poles
- Impact of timing differences on dielectric strength and transient recovery voltage
- Special test procedures to simulate failure modes and controller faults during operation
-
Safety and Environmental Impact
- Rules for transport, installation, maintenance, and safe operation
- Considerations on environmental influences and circuit-breaker sustainability
Applications
IEC TR 62271-302:2010 is essential for the application of circuit-breakers in electrical power networks where pole operation timing control leads to significant advantages:
-
Transformer and Capacitor Switching
Minimizing inrush currents and overvoltages by staggering pole operations reduces mechanical and electrical stress on transformers and capacitors. -
Power System Protection and Reliability
Non-simultaneous pole operation can prevent transient faults and improve system stability during switching operations. -
Controlled Switching in Industrial and Utility Grids
Critical for switching operations in industrial plants and utility substations where sensitive equipment requires precise control of transient voltages. -
Testing and Manufacturing of Specialized Circuit-Breakers
Provides manufacturers with guidelines to design equipment meeting international safety and performance standards.
Related Standards
To effectively use IEC TR 62271-302, reference and understanding of these related standards are recommended:
-
IEC 62271-100:2008 – High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers
(IEC TR 62271-302 supplements and extends this foundational standard.) -
IEC 62271-1 – General definitions for high-voltage switchgear and controlgear
-
IEC 62271-200 – Power switchgear and controlgear – AC disconnectors and earthing switches
-
IEC 60071 series – Insulation coordination standards relevant for dielectric testing and transient voltage analysis
-
IEC 60529 – Degrees of protection provided by enclosures (IP Code), supporting enclosure design in IEC TR 62271-302
Practical Value
Implementing IEC TR 62271-302 guidance enables:
- Enhanced operational reliability and optimized switching performance for high-voltage AC circuit-breakers with non-simultaneous poles
- Improved safety and compliance with international electrical standards
- Detailed understanding of the effects of mechanical timing offsets on electrical transient phenomena
- Better-informed specifications and procurement processes through clear requirements and testing protocols
Professionals responsible for designing or maintaining high-voltage switchgear will find this report invaluable for advancing controlled switching techniques that improve power system longevity and performance.
Технические детали
- Технический комитет
- SC 17A - Switching devices
- SKU
- IEC TR 62271-302:2010
Похожие стандарты
Стандарты, упомянутые в описании
IEC 62271-100:2008
ДействующийHigh-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers
Overview IEC 62271-100:2008 is an international standard established by the International Electrotechnical Commission (IEC) that governs the design, testing, and performance of alternating current (a…
IEC 62271-112:2013
ДействующийHigh-voltage switchgear and controlgear - Part 112: Alternating current high-speed earthing switches for seco…
Overview IEC 62271-112:2013 sets international requirements for high-voltage switchgear, specifically focusing on alternating current high-speed earthing switches (HSES) used for secondary arc extinc…
IEC 62271-200:2011
ДействующийHigh-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated vo…
Overview IEC 62271-200:2011 is an international standard published by the International Electrotechnical Commission (IEC) that defines requirements for high-voltage switchgear and controlgear. Specif…