IEC TS 63392:2025
Fire test for concentrator PV modules
Fire test for concentrator PV modules
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 15
- Дата публикации:
- 20 ноября 2025 г.
- Издание:
- IEC TS 63392 edition 1 version 1
- ICS:
- 27.160
IEC TS 63392:2025 specifies a test method for evaluating the basic fire behaviour of modules used in concentrating systems with a maximum DC system voltage of 1 500 V or less. Since the concentrator module may be exposed to flames due to flying embers or fire may be caused by the module itself due to hot spots or arching (internal fire), the tests outlined in this document are conducted in these two modes. Applicable fire testing may be required by local codes but are not covered in this document. CPV system or CPV modules mounted in or on buildings, shall fulfil national building and construction codes, regulations, and requirements and are not covered by this Technical Specification. If national or local codes define fire test requirements, they should be followed. If such requirements are not available, the following international and national standards give information for tests, which could be used: ISO 5657, ENV 1187-1 to -4, ANSI/UL 790, EN 13501-1.
Abstract
Overview
IEC TS 63392:2025 - Fire test for concentrator PV modules specifies a standardized test method to evaluate the basic fire behaviour of concentrator photovoltaic (CPV) modules and receivers operating at up to 1 500 V DC. The Technical Specification addresses two realistic fire modes:
- External burning-brand exposure (e.g., flying embers or external wildland/roof fire sources) and
- Internal fire scenarios caused by module hot spots, arcing or internal ignition.
The document defines sampling, test set‑up, test conditions, classification criteria and reporting requirements for concentrator PV modules and sub-components.
Key topics and requirements
- Scope and applicability: Applies to concentrator modules/receivers (non-field-adjustable and field-adjustable systems) used in CPV systems; does not replace national building or fire codes for building-mounted installations.
- Two-mode fire testing: Distinct procedures for the external burning-brand test and the internal fire test to reflect real-world ignition mechanisms (flying embers vs. hot spots/arching).
- Sampling rules: Minimum samples for non-field-adjustable modules (typically two production modules for external testing plus one prepared for internal testing). Field-adjustable assemblies may require only receiver-level testing. Representative sub‑samples are permitted when full-size items are impractical.
- Test setup and conditions: Defines test facilities, apparatus, ignition of brands, wind velocity, duration and instrumentation. Includes intrusive and non-intrusive internal test variants and options for bypass/blocking diode thermal testing.
- Classification and reporting: Criteria for pass/fail and a standardized test report format with manufacturing/production notes, specimen details and deviations.
Applications and who uses it
IEC TS 63392:2025 is intended for:
- PV manufacturers designing concentrator modules and receivers (material choice, encapsulation, interconnects).
- Test laboratories and certification bodies performing fire performance assessments for CPV products.
- System integrators, safety engineers and installers assessing fire risk and compliance during product selection and system design.
- Regulators and permitting authorities needing standardized test data to compare fire behaviour of CPV modules.
Practical uses include product development (mitigating hot spots and arcing risks), combined type‑approval test programs (with IEC 62108), pre‑market safety qualification, and documentation for safety dossiers.
Related standards (if applicable)
- IEC 62108 (CPV design qualification and type approval)
- IEC 61730-1 / IEC 61730-2 (PV module safety requirements/testing)
- IEC 60695-11-20 (test flames)
- ISO 5657, ENV 1187-1 to -4, ANSI/UL 790, EN 13501-1 (additional fire test methods and building classification guidance)
Keywords: IEC TS 63392:2025, fire test for concentrator PV modules, CPV fire testing, external burning-brand test, internal hot‑spot test, concentrator PV safety.
Технические детали
- Технический комитет
- TC 82 - Solar photovoltaic energy systems
- SKU
- IEC TS 63392:2025
Похожие стандарты
Стандарты, упомянутые в описании
IEC 62108:2007
ДействующийConcentrator photovoltaic (CPV) modules and assemblies - Design qualification and type approval
Overview IEC 62108:2007 is an international standard developed by the International Electrotechnical Commission (IEC) specifically for concentrator photovoltaic (CPV) modules and assemblies. This sta…
IEC 61730-1:2023
ДействующийPhotovoltaic (PV) module safety qualification - Part 1: Requirements for construction
Overview IEC 61730-1:2023, titled Photovoltaic (PV) module safety qualification – Part 1: Requirements for construction, is an international standard published by the International Electrotechnical C…
IEC 61730-2:2023
ДействующийPhotovoltaic (PV) module safety qualification - Part 2: Requirements for testing
Overview IEC 61730-2:2023 - Photovoltaic (PV) module safety qualification Part 2: Requirements for testing - specifies the test sequence and criteria used to verify the safety of PV modules whose con…
IEC 60695-11-20:2015
ДействующийFire hazard testing - Part 11-20: Test flames - 500 W flame test method
Overview IEC 60695-11-20:2015 is a globally recognized standard from the International Electrotechnical Commission (IEC) focusing on fire hazard testing for electrotechnical products. Specifically, i…
ISO 5657:1997
ДействующийReaction to fire tests — Ignitability of building products using a radiant heat source
Overview ISO 5657:1997 - "Reaction to fire tests - Ignitability of building products using a radiant heat source" specifies a laboratory method to assess the ignitability of essentially flat building…