The principle of the method specified is spraying the extract solution into the flame of the burner of an emission or absorption spectrometer, if necessary with the addition of a spectrochemical buffer solution, or into the flame of a filter flame spectrometer without this addition. For FES and FAAS, the lines at 589,0 nm and 766,5 nm, respectively, are used and compared with the measurements of reference solutions, for a flame filter spectrometer, the specific filters are used. Measures the concentrations of sodium and potassium, expressed as their oxides Na2O and K2O. Applies to the analysis of extract solutions obtained from any kind of glass or glassware.
Abstract
Overview
ISO 10136-2:1993 specifies flame spectrometric methods for the determination of sodium oxide (Na2O) and potassium oxide (K2O) in aqueous extract solutions produced from any kind of glass or glassware. The standard covers sample preparation, use of flame emission (FES), flame atomic absorption (FAAS) and filter flame spectrometry, calibration with reference solutions, and expression of results as micrograms of oxide per millilitre (or related to surface area for extracted glass pieces). The method is intended for hydrolytic resistance and durability testing where alkali release (Na, K) must be quantified.
Key topics and technical requirements
- Principle: spray the extract solution into the flame of an emission or absorption spectrometer (or into a filter flame spectrometer).
- Measurement lines: sodium - 589.0 nm; potassium - 766.5 nm (for FES and FAAS). Filter FES uses appropriate filters for these lines.
- Spectrochemical buffer: a cesium chloride (CsCl) buffer is specified where necessary to reduce interferences; very low-concentration borosilicate extracts may not require buffer.
- Sample preparation: acidification/filtration for turbid samples, pre-treatment of borosilicate storage bottles, dilution or modification of extract to a sample measuring solution, and addition of buffer (typically 5% of flask volume).
- Calibration: prepare stock and standard solutions (Na from NaCl; K from KCl) and construct calibration graphs from a set of reference solutions covering the instrument’s optimum working range.
- Typical working ranges (instrument-dependent): FES/FAAS commonly used for low µg/ml concentrations; filter FES for higher ranges (see instrument guidance in the standard).
- Reagents and apparatus: analytical-grade reagents, hydrochloriс acid for pre-treatment, ashless filter papers, FAAS/FES or filter FES spectrometer, Class A volumetric glassware and pipettes.
Applications and who uses it
- Quality control and compliance testing in:
- Glass and glassware manufacturing (laboratory and pharmaceutical glassware, cookware, packaging)
- Research on chemical durability and hydrolytic resistance of glass formulations
- Independent test laboratories and materials characterization labs performing extract solution analysis
- Regulatory and standards bodies comparing alkali release against specifications or pharmacopoeial limits
- Advantages: provides specific quantification of Na and K (expressed as oxides) rather than total alkalinity from titration, enabling more detailed assessment of glass durability and performance.
Related standards
- Other parts of the ISO 10136 series (methods for CaO/MgO, Al2O3, SiO2, B2O3, Fe2O3 determination)
- Standards referenced for glassware, reagents and water quality such as ISO 3585 (borosilicate glass), ISO 3696 (water for analytical laboratory use), and glass hydrolytic-resistance test standards (e.g., ISO test methods for extract preparation).
Keywords: ISO 10136-2, glass analysis, extract solutions, sodium oxide, potassium oxide, flame spectrometric methods, FES, FAAS, filter flame spectrometer, cesium chloride buffer, hydrolytic resistance.
Технические детали
- Технический комитет
- ISO/TC 48 - Laboratory equipment
- SKU
- ISO 10136-2:1993
Похожие стандарты
Стандарты, упомянутые в описании
ISO 10136-1:1993
ДействующийGlass and glassware — Analysis of extract solutions — Part 1: Determination of silicon dioxide by molecular a…
Overview ISO 10136-1:1993 sets out the international standard procedure for the determination of silicon dioxide (SiO₂) in extract solutions from glass and glassware using molecular absorption spectr…
ISO 3585:1998
ДействующийBorosilicate glass 3.3 — Properties
Overview ISO 3585:1998 specifies the main characteristics of borosilicate glass 3.3, focusing on its physical and chemical properties relevant to its use in laboratory glassware, glass plant, pipelin…