Stationary source emissions — Automated monitoring of mass concentrations of particles — Performance characteristics, test methods and specifications
Stationary source emissions — Automated monitoring of mass concentrations of particles — Performance characteristics, test methods and specifications
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 18
- Дата публикации:
- 6 апреля 1995 г.
- Издание:
- ISO IS 10155 edition 1 version 1
- ICS:
- 13.040.40
Specifies conditions and criteria for the automated monitoring of the mass concentration of particulate matter in stationary source gas streams, including performance characteristics and test procedures. Provides the field evaluation test program and its application to automated monitoring systems. Applicable only on a site-specific basis by direct correlation with the manual testing method in ISO 9096.
Abstract
Overview
ISO 10155:1995 - Stationary source emissions - Automated monitoring of mass concentrations of particles - defines performance characteristics, test methods and specifications for automated monitoring systems used to measure particulate mass concentration in stationary source (stack) gas streams. The standard provides a field evaluation test program and requires site‑specific correlation with the manual gravimetric reference method in ISO 9096. It is equipment‑principle agnostic and focuses on ensuring automated systems are reliable, repeatably calibrated and appropriate for the local emissions profile.
Key topics and technical requirements
- Measurement system components
- Sampling (extractive vs. in‑situ/nonextractive; continuous vs. sequential)
- Analyser (signal generation correlated to mass concentration)
- Data recorder (processing and output in mass concentration)
- Installation criteria
- Representative sampling location adjacent to ISO 9096 reference sampling
- Environmental controls (temperature, weather protection, corrosives, EM fields, vibration)
- In‑stack (optical methods: avoid stray light) vs. out‑of‑stack (short heated sampling lines, isokinetic sampling)
- System performance specifications
- Response time: within the manual reference sampling time
- Zero drift: within ±2% of full working range over one month; automated zero corrections cumulative within 6%
- Span: nominally 2–3× the allowed emission concentration
- Span drift: within ±2% of full working range over one month; automated span corrections cumulative within 6%
- Calibration and statistical criteria
- Correlation coefficient ≥ 0.95 against ISO 9096 reference
- 95% confidence interval within ±10% of a site emission standard
- Tolerance interval: 95% confidence that 75% of values lie within ±25% of the emission standard
- Validation tests
- Response time tests, zero/span field settings and drift measurements, system calibration and field evaluation program
Applications and users
ISO 10155 is used for:
- Commissioning and field evaluation of continuous emission monitoring systems (CEMS) for particulate matter
- Site‑specific calibration and performance verification of automated particulate monitors
- Demonstrating compliance and supporting regulatory reporting where automated systems are correlated to manual methods
Typical users:
- Environmental regulators and compliance auditors
- Plant operators and environmental managers (power plants, cement, steel, incinerators)
- Stack testing laboratories and consultants
- CEMS manufacturers and system integrators
Related standards (if applicable)
- ISO 9096:1992 - Manual gravimetric method (reference method for site correlation)
- ISO 4225, ISO 6879, ISO 7504, ISO 9169 - related vocabulary and measurement performance guidance
Keywords: ISO 10155, automated monitoring, particulate matter, stationary source emissions, CEMS, calibration, performance characteristics, field evaluation, ISO 9096.
Технические детали
- Технический комитет
- ISO/TC 146/SC 1 - Stationary source emissions
- SKU
- ISO 10155:1995
Похожие стандарты
Стандарты, упомянутые в описании
ISO 9096:2017
ДействующийStationary source emissions — Manual determination of mass concentration of particulate matter
Overview ISO 9096:2017 - "Stationary source emissions - Manual determination of mass concentration of particulate matter" - is a reference method for measuring particulate (dust) mass concentration i…
BS ISO 4225:2020
ДействующийAir quality. General aspects. Vocabulary.
ISO 6879:1995
ОтменёнAir quality — Performance characteristics and related concepts for air quality measuring methods
ISO 7504:2015
ДействующийGas analysis — Vocabulary
Overview ISO 7504:2015 - Gas analysis - Vocabulary is an international standard that defines terminology used in gas analysis, with a primary focus on calibration gas mixtures used for gas measuremen…
ISO 9169:2006
ДействующийAir quality — Definition and determination of performance characteristics of an automatic measuring system
Overview ISO 9169:2006 - Air quality: Definition and determination of performance characteristics of an automatic measuring system defines terms and specifies methods to determine the performance cha…