ISO 10322-1:2016
Ophthalmic optics — Semi-finished spectacle lens blanks — Part 1: Specifications for single-vision and multifocal lens blanks
Ophthalmic optics — Semi-finished spectacle lens blanks — Part 1: Specifications for single-vision and multifocal lens blanks
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 3 марта 2016 г.
- Издание:
- ISO IS 10322 edition 4 version 1
- ICS:
- 11.040.70
ISO 10322-1:2016 specifies requirements for the optical and geometrical properties of all semi-finished single-vision and multifocal spectacle lens blanks.
Abstract
Overview
ISO 10322-1:2016 - Ophthalmic optics - Semi‑finished spectacle lens blanks - Part 1 defines the optical and geometrical requirements for semi‑finished single‑vision and multifocal spectacle lens blanks. It sets tolerances, measurement methods and marking/identification rules relevant to manufacturers, optical laboratories and quality assurance teams in the eyewear supply chain.
Key topics and technical requirements
- Scope and classification: Applies to semi‑finished single‑vision and multifocal lens blanks (including blanks that will be finished into spectacle lenses).
- Reference conditions: Measurements apply at 23 °C ± 5 °C and at reference wavelengths per ISO 7944. The manufacturer should specify a reference point (geometric centre assumed if not).
- Surface power tolerances (examples): Surface power tolerances are expressed in dioptres (D) in the material’s refractive index and measured by reflection:
- 0.00–2.00 D: ±0.09 D
-
2.00–10.00 D: ±0.06 D
-
10.00–15.00 D: ±0.09 D
-
15.00–20.00 D: ±0.12 D
-
20.00 D: ±0.25 D
- Intended surface cylindrical power tolerance examples: ≥0.25–4.00 D ±0.06 D; >4.00–6.00 D ±0.09 D; >6.00 D ±0.12 D.
- Addition (ADD) tolerances for multifocals:
- ≤4.00 D: ±0.12 D
-
4.00 D: ±0.18 D
- Uniformity: For nominally spherical surfaces, surface power must not deviate by more than ±0.06 D over a 40 mm diameter zone around the reference point.
- Geometrical tolerances:
- Effective size: dn − 1 mm ≤ de ≤ dn + 2 mm (nominal dn).
- Usable size: du ≥ dn − 1 mm (dn ≤ 65 mm); du ≥ dn − 2 mm (dn > 65 mm).
- Centre and edge thickness: not less than manufacturer’s minimum and not exceed it by more than 3 mm.
- Multifocal segment dimensions: ±0.5 mm (pair difference ≤0.7 mm); segment position ±1.0 mm.
- Test methods: Surface power by reflection instruments, addition measurement by surface methods or focimeter (Annex C), conversion for instrument refractive‑index differences (Annex B). Alternative methods allowed if equivalent.
- Marking & identification: Requirements for lens blank marking and package information to ensure traceability.
Applications and users
- Who uses it: lens blank manufacturers, spectacle lens laboratories, optical quality control teams, eyewear suppliers, regulators and conformity assessors.
- Why it matters: Ensures consistent optical performance, interchangeability of blanks, reliable finishing to prescription, reduced remakes, and compliance with international ophthalmic optics practice.
Related standards
- ISO 7944 (reference wavelengths)
- ISO 8598‑1 (focimeters)
- ISO 13666 (ophthalmic optics vocabulary)
Keywords: ISO 10322-1:2016, ophthalmic optics, semi‑finished spectacle lens blanks, single‑vision lens blanks, multifocal lens blanks, surface power tolerances, addition power, geometrical tolerances, test methods.
Технические детали
- Технический комитет
- ISO/TC 172/SC 7 - Ophthalmic optics and instruments
- SKU
- ISO 10322-1:2016
Похожие стандарты
Стандарты, упомянутые в описании
ISO 7944:2024
ДействующийOptics and photonics — Reference wavelengths
Overview ISO 7944:2024, Optics and photonics - Reference wavelengths, is an international standard published by ISO. This document specifies standard reference wavelengths for the characterization of…
ISO 8598-1:2014
ДействующийOptics and optical instruments — Focimeters — Part 1: General purpose instruments
Overview ISO 8598-1:2014 - "Optics and optical instruments - Focimeters - Part 1: General purpose instruments" - defines requirements and test methods for general-purpose focimeters used in the ophth…