ISO 10993-7:2008
Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals
Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 86
- Дата публикации:
- 13 октября 2008 г.
- Издание:
- ISO IS 10993 edition 2 version 1
- ICS:
- 11.100.20
ISO 10993-7:2008 specifies allowable limits for residual ethylene oxide (EO) and ethylene chlorohydrin (ECH) in individual EO-sterilized medical devices, procedures for the measurement of EO and ECH, and methods for determining compliance so that devices may be released. Additional background, including guidance and a flowchart showing how the standard is applied are also included in informative annexes. EO-sterilized devices that have no patient contact (e.g., in vitro diagnostic devices) are not covered by ISO 10993-7:2008.
Abstract
Overview
ISO 10993-7:2008 - "Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals" defines how to assess and control residual ethylene oxide (EO) and ethylene chlorohydrin (ECH) in EO‑sterilized medical devices. The standard specifies allowable limits, measurement procedures, and product‑release methods so that EO‑sterilized devices with patient contact can be released safely. Devices with no patient contact (e.g., many in vitro diagnostic devices) are excluded. Ethylene glycol (EG) is discussed but no device limits are specified.
Key topics and technical requirements
- Allowable limits: Devices are categorized by duration of contact (limited A, prolonged B, permanent C). Example limits:
- Permanent contact (C): EO average daily dose ≤ 0.1 mg/day; maximum EO 4 mg (first 24 h), 60 mg (first 30 d), 2.5 g (lifetime). ECH average daily ≤ 0.4 mg/day; corresponding early‑use and lifetime caps apply.
- Prolonged exposure (B): EO average daily ≤ 2 mg/day; maximum EO 4 mg (24 h), 60 mg (30 d). ECH average daily ≤ 2 mg/day; ECH early caps apply.
- Measurement methods: Procedures for gas chromatographic determination of EO and ECH are provided (normative and informative annexes). Extraction techniques are defined, including simulated‑use extraction and exhaustive extraction criteria.
- Product release and compliance: Methods include use of residue dissipation curves, release procedures with/without dissipation data, and guidance for interpreting chromatograms and establishing compliance.
- Risk basis: Limits are established to protect against systemic and local effects (e.g., irritation, mutagenicity considerations) and are intended to be used alongside the broader biological evaluation in ISO 10993‑1.
Applications and users
- Who uses it: medical device manufacturers, sterilization engineers, quality assurance, regulatory affairs professionals, testing laboratories, and clinical safety assessors.
- Practical uses:
- Validate EO sterilization processes and specify acceptable post‑sterilization residues.
- Define sampling and analytical testing protocols (GC methods, extraction).
- Establish product release criteria and justify device safety in regulatory submissions.
- Inform material selection and sterilization decisions during device design to minimize residual EO/ECH exposure.
Related standards
- ISO 10993 series (biological evaluation) - especially ISO 10993‑1, ‑3, ‑10, ‑12, ‑17
- ISO 11135‑1 (EO sterilization process requirements)
- Annexes in ISO 10993‑7 include guidance on GC methods, extraction conditions, flowcharts, and rationale for limit derivation.
ISO 10993-7:2008 is essential for ensuring EO‑sterilized medical devices meet toxicological and clinical safety expectations through defined allowable limits, validated measurement methods, and clear product‑release procedures.
Технические детали
- Технический комитет
- ISO/TC 194 - Biological and clinical evaluation of medical devices
- SKU
- ISO 10993-7:2008
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 10993-12:2012
ОтменёнBiological evaluation of medical devices — Part 12: Sample preparation and reference materials
BS EN ISO 10993-7:2026
ДействующийBiological evaluation of medical devices. Ethylene oxide sterilization residuals.
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…