ISO 11140-1:2014
Sterilization of health care products — Chemical indicators — Part 1: General requirements
Sterilization of health care products — Chemical indicators — Part 1: General requirements
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 31
- Дата публикации:
- 31 октября 2014 г.
- Издание:
- ISO IS 11140 edition 3 version 1
- ICS:
- 11.080.01
ISO 11140-1:2014 specifies general requirements and test methods for indicators that show exposure to sterilization processes by means of physical and/or chemical change of substances, and which are used to monitor the attainment of one or more of the process parameter(s) specified for a sterilization process. They are not dependent for their action on the presence or absence of a living organism.
Abstract
Overview
ISO 11140-1:2014 - "Sterilization of health care products - Chemical indicators - Part 1: General requirements" establishes the general requirements and test methods for chemical indicators used to show exposure to sterilization processes. These indicators signal exposure by a physical and/or chemical change (not by biological response) and are intended to monitor attainment of one or more sterilization process parameter(s). This third edition (2014) replaces the 2005 edition and is primarily intended for manufacturers of chemical indicators.
Key topics and technical requirements
- Scope and purpose: Defines general requirements for chemical indicators used with steam, dry heat, ethylene oxide (EO), radiation (γ/β), low-temperature steam/formaldehyde and vaporized hydrogen peroxide sterilization processes.
- Indicator categorization: Chemical indicators are organized into six types:
- Type 1 - Process indicators
- Type 2 - Indicators for specific tests (covered in other ISO 11140 parts)
- Type 3 - Single critical process variable indicators
- Type 4 - Multicritical process variable indicators
- Type 5 - Integrating indicators
- Type 6 - Emulating indicators
This part defines requirements for Type 1 and Types 3–6; Type 2 requirements are provided in ISO 11140-3/4/5.
- Performance and test methods: General performance criteria and process-specific test procedures (steam, dry heat, EO, low-temperature steam/formaldehyde, vaporized hydrogen peroxide, radiation) are specified. It emphasizes use of resistometers for controlled testing (see ISO 18472).
- Additional requirements: Process-specific clauses (e.g., process indicators printed on packaging, steam/dry heat/EO/radiation/VHP) and annexes covering shelf-life testing, example tests, and technical rationale.
Practical applications and users
- Who uses it:
- Chemical indicator manufacturers (design, testing, labeling)
- Sterilization validation engineers and test laboratories
- Medical device manufacturers (process control and packaging validation)
- Hospital sterilization departments and central sterile services (selection and interpretation guidance)
- Regulators and conformity assessment bodies
- How it’s used:
- To design and verify chemical indicators match the intended sterilization process parameters
- To develop validation and routine control programs that complement biological indicators (ISO 11138-series)
- To support selection of appropriate indicator types for packaging, cycles, and specific sterilizers
Related standards
- ISO 11140 series (Parts 3–5 for Type 2/Bowie-Dick and air-removal tests)
- ISO 11135 (Ethylene oxide sterilization)
- ISO 11137 (Radiation sterilization)
- ISO 11138 (Biological indicators)
- ISO 17665 (Moist heat sterilization)
- ISO 18472 (Resistometers)
- ISO 15882 (Guidance on indicator use)
Keywords: ISO 11140-1:2014, chemical indicators, sterilization of health care products, process indicators, integrating indicators, validation, sterilization monitoring.
Технические детали
- Технический комитет
- ISO/TC 198 - Sterilization of health care products
- SKU
- ISO 11140-1:2014
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 11140-4:2007
ДействующийSterilization of health care products. Chemical indicators. Class 2 indicators as an alternative to the Bowie…
BS EN ISO 18472:2018
ДействующийSterilization of health care products. Biological and chemical indicators. Test equipment.
ISO 11138-1:2017
ДействующийSterilization of health care products — Biological indicators — Part 1: General requirements
Overview ISO 11138-1:2017 - Sterilization of health care products: Biological indicators - Part 1: General requirements defines the basic, common requirements for biological indicators (BIs) used in…
ISO 11135:2014
ДействующийSterilization of health-care products — Ethylene oxide — Requirements for the development, validation and rou…
Overview ISO 11135:2014 - Sterilization of health‑care products - Ethylene oxide specifies the requirements for the development, validation and routine control of an ethylene oxide (EO) sterilization…
ISO 11137-2:2013
ДействующийSterilization of health care products — Radiation — Part 2: Establishing the sterilization dose
Overview ISO 11137-2:2013 - “Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose” specifies validated methods to determine the minimum radiation dose requi…
ISO 17665:2024
ДействующийSterilization of health care products — Moist heat — Requirements for the development, validation and routine…
Overview - ISO 17665:2024 (Moist heat sterilization) ISO 17665:2024, "Sterilization of health care products - Moist heat - Requirements for the development, validation and routine control of a steril…