ISO 11174:2023
Workplace air — Determination of particulate cadmium and cadmium compounds — Flame and electrothermal atomic absorption spectrometric method
Workplace air — Determination of particulate cadmium and cadmium compounds — Flame and electrothermal atomic absorption spectrometric method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 26
- Дата публикации:
- 30 мая 2023 г.
- Издание:
- ISO IS 11174 edition 2 version 1
- ICS:
- 13.040.30
This document specifies a method for the determination of the mass concentration of particulate cadmium and cadmium compounds in workplace air, using either flame or electrothermal atomic absorption spectrometry. The sample digestion procedure specified in 10.2.2 has been validated for a selection of cadmium compounds and pigments and glass enamels containing cadmium. The analytical method has been validated for the determination of masses of 10 ng to 600 ng of cadmium per sample using electrothermal atomic absorption spectrometry, and 0,15 µg to 96 µg of cadmium per sample using flame atomic absorption spectrometry. The concentration range for cadmium in air for which this procedure is applicable is determined in part by the sampling procedure selected by the user. The method is applicable to personal sampling of the inhalable or respirable fraction of airborne particles, as defined in ISO 7708, and to stationary sampling.
Abstract
Overview
ISO 11174:2023 - Workplace air: Determination of particulate cadmium and cadmium compounds - Flame and electrothermal atomic absorption spectrometric method - specifies a validated analytical procedure for measuring the mass concentration of particulate cadmium and cadmium compounds in workplace air. The standard covers sample collection (personal or stationary) for inhalable or respirable fractions (as defined in ISO 7708), sample digestion, and analysis by either flame atomic absorption spectrometry (FAAS) or electrothermal atomic absorption spectrometry (ETAAS).
Key practical points:
- Sample substrates: typical filter or foam samplers for inhalable/respirable fractions.
- Sample digestion: nitric acid procedure (diluted 1+1 then concentrated by heating) validated for a range of cadmium compounds, pigments and glass enamels.
- Analysis: FAAS at 228.8 nm or ETAAS with background correction; hollow cathode or electrodeless discharge lamps are used.
- Validated mass ranges: ETAAS - 10 ng to 600 ng Cd per sample; FAAS - 0.15 µg to 96 µg Cd per sample.
- Warning: cadmium is toxic and a suspected human carcinogen; appropriate PPE and controls are required.
Key Topics and Requirements
- Sampling methodology: Personal or stationary sampling; collection characteristics, flow rate, sampling period, and handling of sampler wall deposits are addressed. Sampling targets either inhalable or respirable fractions (ISO 7708).
- Sample preparation: Defined sample dissolution/digestion (see clause 10.2.2) using nitric acid and controlled evaporation and dilution to produce the test solution.
- Instrumental analysis: Procedures for calibration, preparation of calibration solutions, and measurement by FAAS or ETAAS (including use of matrix modifiers and graphite tube atomization for ETAAS).
- Performance parameters: Instrumental detection limits, working range, method detection limits and validated mass ranges for both techniques.
- Quality and reporting: Requirements reference ISO/IEC 17025 competence, documentation of test report content, and method performance evaluation (precision, detection limits).
- Safety: Explicit warning about cadmium toxicity and requirement for protective measures.
Applications and Users
ISO 11174:2023 is designed for:
- Industrial hygienists and occupational health professionals monitoring worker exposures.
- Analytical laboratories performing workplace air analyses and reporting results in compliance with regulatory or corporate exposure limits.
- Regulatory agencies and safety program managers assessing control measures in industries such as battery manufacturing, metal processing, electronics, pigments, glass enamels, mining, and construction.
- Employers and consultants implementing exposure assessment, compliance monitoring and control validation.
Practical benefits include standardized sampling/analysis, traceable results within validated ranges, and guidance to support exposure assessment and risk management.
Related Standards
- ISO 7708 - Particle size fraction definitions for health-related sampling
- ISO/IEC 17025 - Laboratory competence
- ISO 18158 - Workplace air terminology
- ISO 20581 / ISO 21832 - Workplace air measurement requirements and evaluation of measuring procedures
Keywords: ISO 11174:2023, workplace air, cadmium, cadmium compounds, atomic absorption spectrometry, flame AAS, electrothermal AAS, inhalable respirable sampling, occupational exposure monitoring.
Технические детали
- Технический комитет
- ISO/TC 146/SC 2 - Workplace atmospheres
- SKU
- ISO 11174:2023
Похожие стандарты
Стандарты, упомянутые в описании
ISO 7708:1995
ДействующийAir quality — Particle size fraction definitions for health-related sampling
Overview ISO 7708:1995 - "Air quality - Particle size fraction definitions for health-related sampling" defines internationally accepted sampling conventions for airborne particle size fractions used…
BS EN ISO/IEC 17025:2017
ДействующийGeneral requirements for the competence of testing and calibration laboratories.
ISO 18158:2016
ДействующийWorkplace air — Terminology
Overview ISO 18158:2016 - "Workplace air - Terminology" standardizes the vocabulary used for assessing workplace exposure to chemical and biological agents. It defines general terms and terms specifi…
BS ISO 20581:2016
ДействующийWorkplace air. General requirements for the performance of procedures for the measurement of chemical agents.
ISO 21832:2018
ДействующийWorkplace air — Metals and metalloids in airborne particles — Requirements for evaluation of measuring proced…
Overview ISO 21832:2018 - "Workplace air - Metals and metalloids in airborne particles - Requirements for evaluation of measuring procedures" specifies performance requirements and test methods to va…