ISO 11296-7:2019
Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 7: Lining with spirally-wound pipes
Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 7: Lining with spirally-wound pipes
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 16
- Дата публикации:
- 11 января 2019 г.
- Издание:
- ISO IS 11296 edition 2 version 1
- ICS:
- 23.040.20
This document, in conjunction with ISO 11296-1, specifies requirements and test methods for pipes which are formed on site by spirally winding and jointing a pre-manufactured profiled plastics strip, or a profiled plastics strip and integral locking joiner strip, and used for the renovation of underground non-pressure drainage and sewerage networks. It applies to spirally-wound pipes of fixed or variable diameter made of profiled plastics strips, with or without steel stiffening elements, and installed by one of two methods. The first method employs a dedicated winding machine in front of the open end of an existing pipeline, e.g. in a manhole. The pipes thus formed are simultaneously inserted into the existing pipeline by the winding forces, and by certain techniques can also be expanded in diameter after or during insertion. The second method employs a dedicated winding machine which forms the pipe as it traverses the existing pipeline from one manhole to the next. It applies to profiled plastics strips of unplasticized poly(vinyl chloride) (PVC U) with integral locking mechanism, or of high density polyethylene (HDPE) with integrally welded joints.
Abstract
Overview - ISO 11296-7:2019 (Spirally-wound pipes)
ISO 11296-7:2019 is the ISO system standard part that specifies requirements and test methods for lining with spirally-wound pipes used in the renovation of underground non-pressure drainage and sewerage networks. Meant to be applied together with ISO 11296-1 (General), this part covers pipes formed on site by spirally winding a pre-manufactured profiled plastics strip (PVC‑U with integral locking or HDPE with welded joints), including options with steel stiffening elements, and addresses both fixed and variable diameter installations.
Key topics and technical requirements
- Scope and materials: Requirements for profiled plastics strips (PVC‑U or HDPE), seam materials and permissible stiffening elements.
- Geometric, mechanical and physical characteristics: Specifications and test methods for dimensions, ring stiffness, tensile behaviour of seams and other performance metrics in both “as manufactured” (M) and “as-installed” (I) stages.
- Jointing and sealing: Integral locking mechanisms, seam sealants, welds and associated testing for seam integrity and watertightness (including a normative test for watertightness in a deflected condition - Annex A).
- Installation methods: Two approved onsite winding methods - (1) winding at the open pipeline end (e.g., manhole) with simultaneous insertion and optional expansion, and (2) in-line traverse winding from manhole to manhole.
- Installation practice and inspection: Preparatory work, storage/handling, equipment, process-related inspection and testing, lining termination, reconnection of laterals/manholes (examples in Annex B), final inspection, documentation and sample preparation.
- Referenced tests & standards: Uses established test methods such as ring stiffness and tensile testing (normative references include ISO 9969, ISO 13262, ISO 10467, etc.).
Practical applications
- Rehabilitation of sewer and stormwater pipes where non-pressure flow predominates.
- Onsite formation of a new internal lining to extend service life, restore hydraulics and ensure watertightness without full pipeline replacement.
- Situations requiring variable-diameter or expandable liner solutions and limited excavation (manhole‑to‑manhole rehabilitation).
Who should use this standard
- Pipeline rehabilitation contractors and installers
- Manufacturers of profiled plastics strips and spirally‑wound lining systems
- Design engineers, consulting and civil engineers specifying lining systems
- Asset owners, utilities and sewer network operators, inspectors and certification bodies
Related standards
- ISO 11296-1: General requirements for renovation systems
- Other ISO 11296 parts (continuous pipes, cured-in-place, discrete pipes, etc.)
- ISO 9969 (ring stiffness), ISO 13262 (seam tensile testing), ISO 10467 (GRP fittings)
This standard is essential for anyone specifying, producing, installing or certifying spirally-wound plastic linings for underground non-pressure drainage and sewerage rehabilitation.
Технические детали
- Технический комитет
- ISO/TC 138/SC 8 - Rehabilitation of pipeline systems
- SKU
- ISO 11296-7:2019
Похожие стандарты
Стандарты, упомянутые в описании
ISO 11296-1:2018
ДействующийPlastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 1: G…
Overview ISO 11296-1:2018 - Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 1: General. This ISO standard sets out the general requirements an…
ISO 9969:2016
ДействующийThermoplastics pipes — Determination of ring stiffness
Overview ISO 9969:2016 - Thermoplastics pipes - Determination of ring stiffness specifies a laboratory test method for determining the ring stiffness of thermoplastics pipes with circular cross-secti…
BS EN ISO 13262:2017
ДействующийThermoplastics piping systems for non-pressure underground drainage and sewerage. Thermoplastics spirally-for…
ISO 10467:2018
ОтменёнPlastics piping systems for pressure and non-pressure drainage and sewerage — Glass-reinforced thermosetting…
ISO 11296-4:2018
ДействующийPlastics piping systems for renovation of underground non-pressure drainage and sewerage networks — Part 4: L…
Overview ISO 11296-4:2018 specifies requirements and test methods for cured‑in‑place pipes (CIPP) used to renovate underground non‑pressure drainage and sewerage networks. Intended to be used togethe…