ISO 11608-5:2022
Needle-based injection systems for medical use — Requirements and test methods — Part 5: Automated functions
Needle-based injection systems for medical use — Requirements and test methods — Part 5: Automated functions
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 22
- Дата публикации:
- 7 апреля 2022 г.
- Издание:
- ISO IS 11608 edition 2 version 1
- ICS:
- 11.040.25
This document specifies requirements and test methods for automated functions in needle-based injection systems with automated functions (NIS-AUTO). General requirements are provided for all automated functions. In addition, specific requirements are provided for the following automated functions: a) medicinal product preparation (e.g. reconstitution); b) needle preparation; c) needle hiding; d) priming; e) dose setting; f) needle insertion; g) injection depth control; h) injection of the medicinal product; i) recording of device functions; NOTE This document does not cover remote communication from the NIS-AUTO (pertains to wired and wireless communication transfer from the NIS auto). j) disabling the NIS-AUTO; k) needle retraction; l) needle shielding; m) needle removal. All references to "function" in this document are by definition construed as automated functions (see 3.2). This document does not apply to functions that are performed manually by the user.
Abstract
Overview
ISO 11608-5:2022 - "Needle-based injection systems for medical use - Requirements and test methods - Part 5: Automated functions" defines requirements and test methods for automated functions in needle-based injection systems with automated features (NIS‑AUTO). Published as the second edition in 2022, this standard addresses the outputs of design and verification for NIS‑AUTO intended primarily for human medicinal administration. It clarifies what qualifies as an automated function (no user interaction after actuation) and explicitly excludes remote communication functions.
Key topics and technical requirements
The standard provides general requirements applicable to all automated functions and specific requirements and test methods for individual automated functions, including:
- Medicinal product preparation (e.g., reconstitution, reservoir filling)
- Needle preparation, hiding, shielding, removal and needle cover considerations
- Priming and dose setting requirements and verification
- Needle insertion, injection depth control, and intended injection depth definitions and tests
- Injection of the medicinal product (dose delivery, injection time) and dose accuracy testing
- Needle retraction (positioning and completion criteria) and disabling (end‑of‑life state)
- Recording of device functions (data and event logging)
- Test method topics: actuation, test conditions, needle inspection, injection time, retracted position, shielding before/after injection, and dose accuracy at intended depth
The document contains informative annexes (rationale, example dose‑accuracy test, needle extension) and cross‑references to related parts of the ISO 11608 series.
Practical applications and users
ISO 11608-5:2022 is used to:
- Guide design and verification of automated features in injector devices
- Define performance testing protocols for manufacturers and test laboratories
- Support regulatory submissions and conformity assessment by providing standardized test methods and definitions
- Inform risk management, labeling and instructions for use (IFU) where timing, depth, and completion indicators are critical
Primary users:
- Medical device manufacturers (R&D, verification/validation teams)
- Independent test labs and notified bodies
- Regulatory and quality assurance professionals
- Clinical engineers evaluating device safety/performance
Related standards
- ISO 11608-1:2022 - Needle‑based injection systems - Part 1: general requirements (use in conjunction)
- ISO 11608-3:2022 - Containers and integrated fluid paths
- ISO 23908:2011 - Sharps injury protection - sharps protection features
Keywords: ISO 11608-5:2022, needle-based injection systems, NIS-AUTO, automated functions, injection depth control, dose accuracy, test methods, medical device standards.
Технические детали
- Технический комитет
- ISO/TC 84 - Devices for administration of medicinal products and catheters
- SKU
- ISO 11608-5:2022
Похожие стандарты
Стандарты, упомянутые в описании
ISO 11608-1:2022
ДействующийNeedle-based injection systems for medical use — Requirements and test methods — Part 1: Needle-based injecti…
Overview ISO 11608-1:2022 - Needle-based injection systems for medical use (Part 1) specifies requirements and test methods for needle-based injection systems (NISs) designed for single-patient, bolu…
ISO 11608-3:2022
ДействующийNeedle-based injection systems for medical use — Requirements and test methods — Part 3: Containers and integ…
Overview ISO 11608-3:2022 - Needle-based injection systems for medical use - Part 3: Containers and integrated fluid paths - specifies requirements and test methods for design verification of contain…
ISO 23908:2011
ОтменёнSharps injury protection — Requirements and test methods — Sharps protection features for single-use hypoderm…
Overview ISO 23908:2011 specifies requirements and test methods for sharps injury protection features on medical devices that contain sharp hypodermic needles for single use - including single‑use hy…
ISO 11608-7:2016
ДействующийNeedle-based injection systems for medical use — Requirements and test methods — Part 7: Accessibility for pe…
Overview ISO 11608-7:2016 - "Needle-based injection systems for medical use - Part 7: Accessibility for persons with visual impairment" - specifies requirements and test methods to make needle-based…