ISO 11855-6:2018
Building environment design — Design, dimensioning, installation and control of embedded radiant heating and cooling systems — Part 6: Control
Building environment design — Design, dimensioning, installation and control of embedded radiant heating and cooling systems — Part 6: Control
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 13
- Дата публикации:
- 11 сентября 2018 г.
- Издание:
- ISO IS 11855 edition 2 version 1
- ICS:
- 91.040.01
This document establishes guidelines for the control of embedded radiant heating and cooling systems. It specifies uniform requirements for the design and construction of heating and cooling floors, ceiling and wall structures to ensure that the heating/cooling systems are suited to the particular application. The requirements specified in this document are applicable only to the components of the heating/cooling systems and the elements which are part of the heating/cooling surface and which are installed due to the heating/cooling systems. This document is applicable to water-based embedded surface heating and cooling systems in residential, commercial and industrial buildings. The methods apply to systems integrated into the wall, floor or ceiling construction without any open air gaps. It is not applicable to panel systems with an open air gap which is not integrated with the building structure. This document also applies, as appropriate, to the use of fluids other than water as a heating or cooling medium. This document is not applicable for testing of systems. The methods do not apply to heated or chilled ceiling panels or beams.
Abstract
Overview
ISO 11855-6:2018 - "Building environment design - Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 6: Control" provides guidelines and uniform requirements for the control of embedded radiant heating and cooling systems. It covers water-based (and, where appropriate, other fluid-based) systems integrated into floors, walls or ceilings without open air gaps. The standard is applicable to residential, commercial and industrial buildings and focuses on ensuring systems perform as designed, avoid condensation and protect building fabric (it does not cover panel systems with open air gaps, heated/chilled ceiling panels or beams, nor is it a test standard).
Key Topics and Requirements
- Control system design and documentation: Control strategies and specifications shall be included in design documents; systems must vary output and maintain room/surface temperatures as designed.
- Control levels:
- Central control - building-wide supply temperature and distribution management (mixing valves, supply/return monitoring).
- Zone control - groups of spaces with similar temperature requirements controlled together.
- Local (room) control - individual room sensors and actuated manifold valves for occupant comfort and energy savings.
- Control performance classes: Manual, automatic, timing (scheduled setbacks), and advanced timing with optimized restart strategies.
- Sensors and inputs: Outside temperature sensors, room temperature/humidity sensors, floor/surface sensors, supply/return medium temperature sensors - used for feed-forward and feedback control and integration with a Building Management System (BMS).
- Condensation prevention: Controls must avoid surface condensation in cooling mode (e.g., limiting minimum supply water temperature based on measured dew point).
- Hydronic control details: Mixing valve control, flow control (new in 2018 edition), and recommendations to control mean water temperature (average of supply and return) for more direct relation to space flux.
- Dynamic factors: Influence of thermal mass, self-regulating effects of embedded systems and control of Thermo Active Building Systems (TABS) are addressed.
- Informative guidance: Annex A provides example control concepts for radiant floor heating–cooling systems.
Applications and Users
Who uses ISO 11855-6:2018:
- HVAC designers and engineers specifying hydronic radiant systems
- Building services consultants and BMS integrators implementing central/zone/room control
- Architects and project managers coordinating embedded system integration with building structure
- Facility managers operating and maintaining radiant heating and cooling systems Practical uses include designing control logic, selecting sensors and actuators (mixing valves, pumps), setting condensation protection, and optimizing energy use through zoning and timing strategies.
Related Standards
- ISO 11855-1 (definitions, symbols, comfort criteria) - normative reference
- Other parts of ISO 11855 series (Parts 2–5, 7) cover sizing, dimensioning, installation and TABS design
- ISO 52031 (energetic calculations) - related for energy performance input (under development at time of publication)
Keywords: ISO 11855-6, embedded radiant heating and cooling, hydronic control, radiant floor cooling, TABS, mixing valve, condensation control, zone control, room sensor, BMS.
Технические детали
- Технический комитет
- ISO/TC 205 - Building environment design
- SKU
- ISO 11855-6:2018
Похожие стандарты
Стандарты, упомянутые в описании
ISO 11855-1:2021
ДействующийBuilding environment design — Embedded radiant heating and cooling systems — Part 1: Definitions, symbols, an…
Overview ISO 11855-1:2021 - Building environment design - Embedded radiant heating and cooling systems - Part 1: Definitions, symbols, and comfort criteria - provides the foundational terminology, sy…
BS EN ISO 11855-8:2023
ДействующийBuilding environment design. Design, dimensioning, installation and control of embedded radiant heating and c…
ISO 52031:2020
ДействующийEnergy performance of buildings — Method for calculation of system energy requirements and system efficiencie…
Overview ISO 52031:2020 - Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Space emission systems (heating and cooling) defines the str…