ISO 11883:1997
Optics and optical instruments — Microscopes — Marking of stereomicroscopes
Optics and optical instruments — Microscopes — Marking of stereomicroscopes
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 4
- Дата публикации:
- 10 апреля 1997 г.
- Издание:
- ISO IS 11883 edition 1 version 1
- ICS:
- 37.020
This International Standard specifies the format for the marking of data for optical characteristics on stereomicroscopes, including operation microscopes, and gives recommendations for the marking of additional information.
Abstract
Overview
ISO 11883:1997 is an international standard issued by the International Organization for Standardization (ISO) that specifies the requirements for the marking of stereomicroscopes, including operation microscopes used in surgical settings. This standard outlines the format for displaying essential optical data on stereomicroscopes to ensure clarity, uniformity, and regulatory compliance. It also provides recommendations for additional information markings to enhance user understanding and instrument traceability.
The standard applies to the marking of stereomicroscope components such as the main body, interchangeable objectives, zoom changers, binocularity tubes, accessories in the optical path, and ocular lenses. By adhering to ISO 11883 guidelines, manufacturers and users can accurately identify optical properties, magnification levels, and other critical data, thereby supporting consistent use and maintenance.
Key Topics
-
Marking on Microscope Body
- Manufacturer name (mandatory)
- Country of origin (recommended or mandatory depending on region)
- Model or type designation (recommended)
- Serial or reference number (recommended)
-
Objective Lens Markings
- Magnification coefficient (mandatory except for fixed 1.0x lenses)
- Focal length, given in millimeters (mandatory)
- Working distance (recommended, particularly important for surgical microscopes)
-
Zoom or Magnification Changer Markings
- Indication of all magnification steps or scale values (mandatory)
- Total magnification indication for fixed objectives and oculars
-
Binocular Tube Markings
- Magnification coefficient, if different from 1.0x (mandatory)
- Focal length of tube lens (recommended, especially in surgical microscopes)
-
Optical Accessories Markings
- Magnification coefficient when it modifies the total magnification (mandatory)
-
Ocular Lens Markings
- Angular magnification (mandatory unless total magnification is indicated on zoom changer)
- Field of view diameter in mm (mandatory)
- Manufacturer identification (mandatory)
- Correction type (recommended)
- Compatibility for eyeglass wearers (recommended)
-
Total Magnification Calculation
- Product of objective magnification, ocular magnification, and any magnification factors from changers, tubes, or accessories placed in the optical path.
Applications
ISO 11883:1997 is essential for manufacturers, quality controllers, and users of stereomicroscopes in various fields such as:
-
Medical and Surgical Settings
Ensures precise marking of stereomicroscopes used in microsurgery for clarity and safety in operation. -
Research Laboratories
Provides clear visualization detail by standardized marking of optical parameters, aiding in reproducible results. -
Educational Institutions
Facilitates understanding of stereomicroscope specifications for effective student training. -
Manufacturing and Quality Assurance
Enables compliance with internationally recognized marking formats essential for regulatory approvals and export. -
Repair and Maintenance
Simplifies identification of parts and their optical characteristics during servicing.
Related Standards
-
ISO/TC 172
Technical committee overseeing optics and optical instruments, under which ISO 11883 was developed. -
ISO 8036
Standard relating to terminology for microscopes, complementing marking standards. -
IEC Standards on Optical Instruments
For integration of electrical components in operation microscopes.
Summary
ISO 11883:1997 provides a comprehensive format for marking the optical properties and relevant information on stereomicroscopes and their components to ensure consistency, safety, and ease of use across international borders. Implementation of this standard enhances transparency and reliability in optical characterization which benefits manufacturers, end-users, and regulatory bodies alike.
Keywords: ISO 11883, stereomicroscope marking, optical instruments, microscope labeling, magnification coefficients, working distance, optical standards, surgical microscope markings, microscopy standardization.
Технические детали
- Технический комитет
- ISO/TC 172/SC 5 - Microscopes and endoscopes
- SKU
- ISO 11883:1997
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 80369-20:2015
ДействующийSmall-bore connectors for liquids and gases in healthcare applications -- Part 20: Common test methods
Overview - ISO 80369-20:2015 (Common test methods for small-bore connectors) ISO 80369-20:2015 defines the common test methods used to evaluate the performance requirements of small-bore connectors f…
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…
ISO 7574-3:1985
ДействующийAcoustics — Statistical methods for determining and verifying stated noise emission values of machinery and e…
Overview ISO 7574-3:1985 is part of the ISO 7574 series on acoustics and provides a simple (transition) statistical method for determining and verifying stated noise emission values for batches (lots…