ISO 12500-3:2009
Filters for compressed air — Test methods — Part 3: Particulates
Filters for compressed air — Test methods — Part 3: Particulates
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 15
- Дата публикации:
- 24 июня 2009 г.
- Издание:
- ISO IS 12500 edition 1 version 1
- ICS:
- 23.100.60
ISO 12500-3:2009 provides a guide for choosing an appropriate method of determining the solid particulate removal efficiency rating by particle size of filters used in compressed air systems. ISO 12500-3:2009 specifies the layouts and procedures for testing these filters. Measurement methods are recommended based on the size range of the particulates that the filter being tested has been designed to remove. The test is performed as a “type-test” on filters as being representative of a range. The following two particle diameter size ranges are identified in ISO 12500-3:2009: a fine filter range, 0,01
Abstract
Overview
ISO 12500-3:2009 - Filters for compressed air - Test methods - Part 3: Particulates specifies test layouts and procedures to determine the solid particulate removal efficiency by particle size for filters used in compressed air systems. It defines two particle-size ranges - fine (0.01 µm to <5.0 µm) and coarse (≥5.0 µm to ≤40 µm) - and recommends measurement methods and instruments appropriate to each. Tests are performed as type-tests meant to represent a range of filter elements and include requirements for aerosol generation, sampling, and data reporting.
Key topics and technical requirements
- Particle size ranges: Fine (0.01 µm–<5 µm) and coarse (5 µm–40 µm).
- Measurement methods: Recommended instruments include LPC (laser particle counter), OAS (optical aerosol spectrometer), and mobility/condensation systems such as SMPS, DMA, CPC/CNC depending on particle size and concentration.
- Aerosol challenge: Fine-particle tests use NaCl, KCl or DEHS aerosols (per EN 1822 series); coarse tests use ISO 12103-1 A4 (Arizona) test dust prepared and dried to specified conditions.
- Sampling & detection: Fine-particle sampling follows ISO 8573-4; coarse-particle methods are specified in ISO 12500-3. Correct for counting-efficiency differences when using multiple particle counters.
- Operational conditions: Reference conditions are 20 °C and 100 kPa (1 bar); preferred test pressure is 700 kPa(e) [7 bar(e)], but alternative pressures are allowed if equivalent flow velocity is maintained. Turbulent flow (Reynolds number > 4 000) is required for representative sampling.
- Test procedure: Minimum of three complete test cycles with a new filter per run; record pressure drop at start and end; results typically reported as efficiency vs particle size curves and include measurement uncertainty.
- Most Penetrating Particle Size (MPPS): Locate MPPS using monodisperse aerosols for fine-filter characterization.
Applications and who uses it
ISO 12500-3 is used by:
- Filter manufacturers for type-testing and product specification.
- Independent test laboratories performing standardized efficiency measurements.
- Compressed air system designers and maintenance engineers selecting filters to meet required purity classes (e.g., ISO 8573 series).
- Quality, procurement, and compliance teams in industries such as pharmaceuticals, food & beverage, electronics, and general manufacturing where particle-free compressed air is critical.
Practical applications include selecting the right particulate filter for process lines, verifying filter performance claims, and ensuring compatibility with system pressure, flow and required compressed air purity.
Related standards
- ISO 12500-1, ISO 12500-2 (other parts of Filters for compressed air)
- ISO 8573-1 and ISO 8573-4 (compressed air purity and particle testing)
- EN 1822-1 / EN 1822-2 (aerosol generation and particle counting)
- ISO 12103-1 (test dust - Arizona)
Технические детали
- Технический комитет
- ISO/TC 118/SC 4 - Compressed air treatment technology
- SKU
- ISO 12500-3:2009
Похожие стандарты
Стандарты, упомянутые в описании
BS EN 1822-1:2019
ДействующийHigh efficiency air filters (EPA, HEPA and ULPA). Classification, performance testing, marking.
BS ISO 12103-1:2024
ДействующийRoad vehicles. Test contaminants for filter evaluation. Arizona test dust.
ISO 8573-4:2001
ОтменёнCompressed air — Part 4: Test methods for solid particle content
BS ISO 12500-3:2009
ДействующийFilters for compressed air. Test methods. Particulates.
ISO 8573-3:1999
ДействующийCompressed air — Part 3: Test methods for measurement of humidity
Overview ISO 8573-3:1999 - "Compressed air - Part 3: Test methods for measurement of humidity" defines guidance for selecting and using suitable humidity measurement methods for compressed air. The s…
BS ISO 12500-1:2007
ДействующийFilters for compressed air. Test methods. Oil aerosols.
BS ISO 12500-2:2007
ДействующийFilters for compressed air. Test methods. Oil vapours.
ISO 8573-1:2010
ДействующийCompressed air — Part 1: Contaminants and purity classes
Overview ISO 8573-1:2010 - "Compressed air - Part 1: Contaminants and purity classes" defines a classification system for compressed air purity with respect to the main contaminants: particles, water…