ISO 15001:2010
Anaesthetic and respiratory equipment — Compatibility with oxygen
Anaesthetic and respiratory equipment — Compatibility with oxygen
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 40
- Дата публикации:
- 20 мая 2010 г.
- Издание:
- ISO IS 15001 edition 2 version 1
- ICS:
- 11.040.10
ISO 15001:2010 specifies requirements for the oxygen compatibility of materials, components and devices for anaesthetic and respiratory applications, which can come into contact with oxygen in normal condition or in single fault condition at gas pressures greater than 50 kPa. Additionally, ISO 15001:2010 gives general guidelines for the selection of materials and components based on available data on their oxygen compatibility, and for carrying out a risk analysis, including addressing the toxicity of products of combustion and/or decomposition. Aspects of compatibility that are addressed by ISO 15001:2010 include cleanliness, resistance to ignition and the toxicity of products of combustion and/or decomposition at the design, manufacturing, maintenance and disposal stages. ISO 15001:2010 is applicable to anaesthetic and respiratory equipment that is within the scope of ISO/TC 121, e.g. medical gas pipeline systems, pressure regulators, terminal units, medical supply units, flexible connections, flow-metering devices, anaesthetic workstations and lung ventilators.
Abstract
Overview
ISO 15001:2010 - Anaesthetic and respiratory equipment - Compatibility with oxygen specifies requirements and guidance for ensuring materials, components and devices used with oxygen (or oxygen-enriched mixtures) are compatible and safe. The standard applies where contact with oxygen can occur in normal or single-fault conditions at gas pressures greater than 50 kPa. It addresses design, manufacture, cleaning, testing and risk analysis to reduce fire, ignition and toxic combustion hazards in anaesthetic and respiratory equipment.
Key topics and technical requirements
- Scope and applicability
- Applicable to equipment in the ISO/TC 121 domain (e.g., medical gas pipeline systems, pressure regulators, terminal units, flexible connections, flow‑metering devices, anaesthetic workstations and lung ventilators).
- Not intended for biocompatibility assessment.
- Cleanliness
- Surfaces contacting oxygen must meet defined hydrocarbon contamination limits for oxygen service:
- 50 kPa to 3 000 kPa: maximum hydrocarbon contamination specified (document cites 550 mg/m² as guidance).
- > 3 000 kPa: stricter hydrocarbon limit (document cites 220 mg/m²) and particle size ≤ 100 µm.
- Manufacturers must provide identification, packaging and handling to maintain oxygen-clean status and validate cleaning methods (Annexes A and B give examples).
- Surfaces contacting oxygen must meet defined hydrocarbon contamination limits for oxygen service:
- Resistance to ignition
- Devices designed for pressures > 3 000 kPa shall not ignite under pneumatic impact testing at 1.2 × nominal inlet pressure. Lubricated devices must be tested as used.
- Annex C covers design considerations that reduce ignition risk.
- Risk management and toxicity
- Manufacturers shall implement a risk management process in accordance with ISO 14971, addressing oxygen fire hazards, ignition resistance, cleaning, material selection and toxicity of combustion/decomposition products (Annexes D and E provide material selection guidance and combustion-product analysis).
- Supporting guidance
- Informative annexes A–F include cleaning procedures, validation methods, design considerations, selection of materials, combustion analysis methods and rationale.
Practical applications - who uses ISO 15001:2010
- Medical device manufacturers designing or producing anaesthetic and respiratory equipment intended for oxygen service
- Product and mechanical engineers specifying materials, lubricants and seals for oxygen systems
- Quality, cleaning-validation and manufacturing professionals responsible for oxygen‑clean processes
- Regulatory bodies, notified bodies and testing laboratories assessing oxygen compatibility and safety
- Maintenance teams and hospital biomedical engineers managing equipment in oxygen-enriched environments
Related standards
- ISO 14971 - Medical devices - Application of risk management
- Device and test standards referenced for pneumatic impact testing (e.g., ISO 10524 series, ISO 10297, ISO 21969, ISO 7291)
- References and industry guidance such as ASTM and EIGA documents are cited in the standard for contamination and test criteria.
ISO 15001:2010 is essential for reducing ignition and toxic hazards in oxygen service and for demonstrating robust cleaning, design and risk-management practices for anaesthetic and respiratory equipment.
Технические детали
- Технический комитет
- ISO/TC 121/SC 6 - Medical gas supply systems
- SKU
- ISO 15001:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 14971:2007
ДействующийMedical devices - Application of risk management to medical devices
Overview ISO 14971:2007 - Medical devices - Application of risk management to medical devices - defines a systematic process for identifying hazards, estimating and evaluating risks, implementing ris…
ISO 10524-1:2018
ДействующийPressure regulators for use with medical gases — Part 1: Pressure regulators and pressure regulators with flo…
Overview ISO 10524-1:2018 - "Pressure regulators for use with medical gases - Part 1: Pressure regulators and pressure regulators with flow‑metering devices" defines safety, design and testing requir…
BS EN ISO 10297:2024
ДействующийGas cylinders. Cylinder valves. Specification and type testing.
BS EN ISO 21969:2009
ДействующийHigh-pressure flexible connections for use with medical gas systems.
ISO 7291:2010
ДействующийGas welding equipment — Pressure regulators for manifold systems used in welding, cutting and allied processe…
Overview ISO 7291:2010 - "Gas welding equipment - Pressure regulators for manifold systems used in welding, cutting and allied processes up to 30 MPa (300 bar)" specifies performance, design and test…